《FORD FLTM BQ 103-06-2000 MEASUREMENT OF CRACK DENSITY OF MICRO-CRACKED OR PORE DENSITY OF MICRO-POROUS ELECTRODEPOSITED CHROMIUM (Replaces FLTM BQ 003-06)《微孔铬电沉积层的微细裂纹的密度或电沉积层的孔隙密度.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BQ 103-06-2000 MEASUREMENT OF CRACK DENSITY OF MICRO-CRACKED OR PORE DENSITY OF MICRO-POROUS ELECTRODEPOSITED CHROMIUM (Replaces FLTM BQ 003-06)《微孔铬电沉积层的微细裂纹的密度或电沉积层的孔隙密度.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BQ 103-06 Date Action Revisions 2000 11 10 Revised Editorial no technical change A. Cockman 1999 01 20 Printed copies are uncontrolled Page 1 of 6 Copyright 2000, Ford Global Technologies, Inc. MEASUREMENT OF CRACK DENSITY OF MICRO-CRACKED OR PORE DENSITY OF MICRO-POROUS
2、 ELECTRODEPOSITED CHROMIUM Application This procedure is used to determine the crack density of micro - cracked or the pore density of micro - porous electroplated deposits. Apparatus Required Anode A copper anode should be used. Current Source A D -C current source capable of supplying a current de
3、nsity of 1.6 A/dm to the surface being evaluated. A satisfactory current source is available from Hewlett Packard. Ammeter An ammet er is connected to the circuit to determine the current. The measuring range of the ammeter used will depend upon the surface area to be plated. Plating Tank (for Metho
4、d A) The tank should be of sufficient size to completely immerse the item to be tested in the plating solution. The tank should be constructed in such a manner that any surfaces coming into contact with the plating solution should be non -reactive with the solution. A VWR #60462 series or equivalent
5、 tank of the proper size would be satisfa ctory. Source: VWR Scientific Retaining Ring (for Method B) If necessary, a retaining ring, constructed of a non - reactive material may be used to support the viscous electrolyte. This retainer may be customer made to conform to a particular part configu ra
6、tion in the area to be tested. Metallurgical Microscope A metallurgical microscope is to be used in determining either crack density or pore density. A Meiji binocular, 4X, 10X, 20X, 40X, objective 10 eye pieces, 4x4 mechanical stage, Model ML7000 or e quivalent is satisfactory. For determining crac
7、k density a cross line disc Leica #31 - 16 - 30 or equivalent is required. For determining pore density a Howard Disc Leica #31 - 16 - 15 or equivalent is required; 25 mm long with 1.0, 0.1 and 0.02 mm divisions. Source: I.Miller Precision Optical Instrument Inc. 35 N. Second St. Philadelphia, PA 19
8、106 Tel : (215)925 - 2285 Fax: (215)925 - 8374 FORD LABORATORY TEST METHOD BQ 103-06 Page 2 of 6 Copyright 2000, Ford Global Technologies, Inc. Materials Required Tri Sodium Phosphate M - 1048 Sulfuric Acid 5% by volume H 2 SO 4 ; Reagent grade. Caution: Corrosive Copper Sulfate CuSO 4 ; Reagent gra
9、de. Agar-Agar Copper Fluoborate Cu(BF 4 ) 2 ; Reagent grade. Distilled or Deionized Water 10 ppm dissolved solids maximum (ASTM D 1880). Solutions Required Cleaning Solution 1. 22 - 30 g/L of Tri Sodium Phosphate (M - 1048). 2. D eionized water baths. 3. A bath of 5% by volume sulfuric acid in deion
10、ized water. Method A Copper Sulfate (CuSO 4 5H 2 0) 210 - 240 g/L Sulfuric Acid (H 2 SO 4 ) 45 - 60 g/L NOTE: Always add acid to the water Method B Solution for use with retaining rin g: Agar - Agar 50 - 70g Copper Fluoborate (Cu(BF 4 ) 2 ) 250 mL H 2 O (distilled or deionized) 750 mL FORD LABORATOR
11、Y TEST METHOD BQ 103-06 Page 3 of 6 Copyright 2000, Ford Global Technologies, Inc. Solution for use without retaining ring: Agar - Agar 100 - 150 g Copper Fluoborate (Cu(BF 4 ) 2 ) 250 mL H 2 0 (distilled or deioni zed) 750 mL Masking Material Hardman Extra Fast Setting Epoxy, or X - P 2000 masking
12、material, or equivalent Source: Harcos Chemicals Inc. A&M Industrial 600 Cortland St. 2565 Trotter Drive Belleville, NJ 07109 Alpharetta, GA 30004 Tel: (201) 751 - 3000 Tel : (800) 446 - 4750 Fax: (770)772 - 6403 Conditioning and Test Conditions All test values indicated herein are based on material
13、 conditioned in a controlled atmosphere of 23 +/ - 2 C and 50 +/ - 5% humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. Procedure Method A The specimen to be tested should have been recently chromium plated to ensure reliability of resu
14、lts. 1. Mask all cut edges and, if practicable, all su rfaces not chromium plated. The conductor carrying current to the specimen during plating should also be masked at and below solution level, except where it makes contact with the specimen. 2. Soak the masked specimen in the hot alkaline cleaner
15、 at a tem perature of 70 - 85 C. 3. Rinse in hot deionized water at a temperature of 80 - 90 C. 4. Dip in the 5% sulfuric acid solution (in and out). 5. Rinse in hot deionized water bath (2nd rinse) at a temperature of 80 - 90 C. 6. Using “live“ entry, plate the specimen (part is cathodic) at 0.3 am
16、p/dm of immersed plated surface for 15 minutes. 7. Rinse the specimen carefully in cold (approximately 5 - 15 C) and then in hot tap water (approximately 45 - 65 C) and allow to dry. DO NOT WIPE, RUB OR TOUCH TH E AREAS ON WHICH PORES ARE TO BE COUNTED. (The copper nodules which are deposited at the
17、 discontinuity or crack sites are not firmly attached, and any physical contact after copper plating may remove some of these nodules and cause serious errors in measu rement.) FORD LABORATORY TEST METHOD BQ 103-06 Page 4 of 6 Copyright 2000, Ford Global Technologies, Inc. Method B 1. Clean the area
18、 to be tested as in Steps 2 - 5 of Method A. 2. Place the retaining ring and electrolyte - gel (or electrolyte - gel only if self - supporting gel is employed) on the area to be tested. 3. Place the copper anode, such as a piece of copper foil, within the gel. 4. Pass a current of 1.6 dm 2 of covere
19、d surface for 15 minutes through the part. (The test part becomes the cathode.) 5. Rinse and discard the gel carefully from the test part. The part should be treated as in Ste p 7, Method A. A. Grid Method - Visual, Using a Metallurgical Microscope 1. In a suitable 10X microscope eyepiece, insert a
20、micrometer disc (Howard Micrometer Disc, Leica #31 - 16 -15) containing ruled grid squares. The eyepiece should be capable of accom modating the disc in the proper focal plan so that the grid and the image of the plated surface are clear and sharp. 2. Using a standard metallurgical microscope with t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBQ103062000MEASUREMENTOFCRACKDENSITYOFMICROCRACKEDORPOREDENSITYOFMICROPOROUSELECTRODEPOSITEDCHROMIUMREPLACESFLTMBQ00306

链接地址:http://www.mydoc123.com/p-747472.html