1、FORD LABORATORY TEST METHOD BP 118-01 Date 2001 O924 1990 O1 04 MOISTURE INGRESS TEST FOR AIR CONDITIONING REFRIGERANT HOSES Action Revisions Revised Editorial - no technical change A. Cockman Application This procedure is used to measure the amount of moisture that permeates the hose samples when t
2、hey are subjected to a humid environment with vacuum being drawn on the I.D. of the hose samples. Apparatus Required Humidity Cabinet Thermotron or equivalent, maintained at 50 +/- 2 OC and 85 +/- 5 % relative humidity Oven Blue M, or equivalent, maintained at 100 +/- 2 OC Balan ce r Mettler, or equ
3、ivalent, balance capacity of 160 g with an accuracy of +/-0.0001 g Desiccator With a capacity for one set of cold traps Vacuum Pump With a capacity of 95 kPa VacuumlCold Trap System Materials Required Distilled Water Dry Nitrogen Gas Laboratory grade Cold Bath Maintained at -70 OC or lower Copynght0
4、2001, Ford Global Technologies, Inc FORD LABORATORY TEST METHOD BP 118-01 Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 OC and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested
5、under the same conditions unless otherwise specified. Procedure Throughout this test procedure, there are references to corresponding numbers shown in the Schematic Diagram of Test System identified as Figure 1. 1. 2. 3. 4. 5. 6. 7. Install the test assemblies in the humidity cabinet by plugging one
6、 end-fitting and attaching the other end to the vacuum lines located in the cabinet. Arrange the test assemblies to maximize surface exposure to test chamber ambient conditions without bending the sample in an arc of a radius smaller than 254 mm. Seal the humidity cabinet and set the controls to mai
7、ntain a dry bulb temperature of 50 +/- 2 OC and 85 +/- 5 % relative humidity. Thoroughly clean all vacuum traps, inside and out. Then place the traps in an oven set at 100 +/- 2 OC until thoroughly dry. Remove the traps from the oven, transfer to drying desiccator and allow them to cool to room temp
8、erature. Weigh each trap to the nearest 0.5 mg. Install the traps in the test system (Item 5, Figure I), in the cold bath maintained at -70 +/- 2 OC or lower throughout the test. After all connections are made, turn on the vacuum pump and open Valve No. 2 and then Valves No. 11 and 12. Valve No. 9 s
9、hould be closed. a. A quick leak check can be done by closing Valve No. 12 for about 15 seconds and noting any vacuum decay on Gage No. 6. If there is any vacuum loss, the leak should be located, sealed and the system rechecked. b. Open Valve No. 12. C. Evacuate the system to a vacuum of 95 kPa or g
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBP11812001MOISTUREINGRESSTESTFORAIRCONDITIONINGREFRIGERANTHOSESPDF

链接地址:http://www.mydoc123.com/p-747444.html