FORD FLTM BO 110-01-2013 TEXTURE MEASUREMENT.pdf
《FORD FLTM BO 110-01-2013 TEXTURE MEASUREMENT.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BO 110-01-2013 TEXTURE MEASUREMENT.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD FLTM BO 110-01 Date Action Revisions Rev. 0 2013 12 09 Released In reference to international standards M. Galonska, C. Starke Controlled document at www.MATS Copyright 2013, Ford Global Technologies, Inc Page 1 of 6 TEXTURE MEASUREMENT 1. Scope and Field of Application
2、1.1 Scope This objective method covers an instrumental comparison of a samples texture against a reference by defining measurement conditions and measurement procedures for the measurement of texture. The aim is to instrumentally determine those texture differences between sample and reference, whic
3、h are caused by materials, processing, or which arise after testing of, e.g. scratching. 1.2 Field of Application The application is valid for all textured surfaces of the vehicle interior except fabric and carpet. Areal topography measurement is preferred to line topography measurement. In case of
4、doubt areal topography characteristics overrule line topography characteristics. Application of topography gauges (tactile vs. non-tactile): Measurement approach Line topography measurement Areal topography measurement Measurement principle tactile non-tactile tactile non-tactile Hard trim plastic s
5、urfaces + + + + Soft surfaces (leather, vinyl, etc.) - + - + Tool steel surface (injection mold, etc.) + + + + 2. Definitions Terms and definitions in terminology ISO 25178 (areal topography), ISO 4287 and ISO 4288 (line topography) are applicable to this method. Definitions of terms specific to thi
6、s method are surface characteristics that describe the primary topography and roughness topography. 2.1 Instrument Master instrument The Master Instrument is an instrument to establish the basic references among various levels of standards and among other equipments. This instrument is the normal ar
7、biter in any situation not adequately resolved at a lower level and is retained by the organization that issues the masters. Secondary instrument A Secondary Instrument is any other instrument used for texture evaluation of the product by reference to the masters. FORD LABORATORY TEST METHOD FLTM BO
8、 110-01 Copyright 2013, Ford Global Technologies, Inc. Page 2 of 6 2.2 Masters Target A physical design idea representation (intended to be developed). Internal Approval A physical representation approved to the target released to go to testing. Final Approval A physical representation approved to t
9、he internal approval released to master. Master A physical representation meant to define design Intent, which is distributed. Graduated Version A physical representation meant to define the graduated grain versions according to the master. Regional Standard A physical representation of a regional l
10、evel capability to the master; for distribution within the specific region only (most be coded different to master). Reference Approval A visual approval to either a master or regional standard to validate Design Intent and verify feasibility of specific materials. 2.3 Reference A master or any othe
11、r physical sample that the measurement of samples is correlated to. If only compared within a sample lot, the one sample is chosen to be reference that is visually closest to the idea/vision of the evaluator. 3. Method the lateral resolution should be 10 m. For 2D tactile (contact) devices only: Pro
12、filometers should use a stylus tip of radius 2 m and point angle of 60 (ISO 3274). The measuring range shall be 300 m. In the case that the measuring velocity is adjustable it is recommended to select the lowest in order to increase the accuracy. For 3D devices only: Areal topography scanning device
13、s with a fixed measuring areal shall have a minimum size of 10 mm x 8 mm. FORD LABORATORY TEST METHOD FLTM BO 110-01 Copyright 2013, Ford Global Technologies, Inc. Page 3 of 6 3.2.2 Instruments proposed Instrument Master GFM (non-tactile areal topography gauge) MikroCADpremium Secondary FRT CWL (non
14、-tactile areal topography gauge) 3.2.3 Maintenance and Calibration Maintenance and calibration is of prime importance in providing constant and reliable measurements. The instrument has to be maintained and calibrated in accordance with the instructions of the equipment manufacturer. The instrument
15、shall NOT be calibrated NOR charged within a series of measurements. The instrument shall be calibrated according to the manufacturers instructions at least once a year. 2D tactile profilometers need to have a geometry measurement standard (ISO 5436, type C1) and a roughness measurement standard (IS
16、O 5436-1, type D1) which has to be tested before a set of measurements is started. A tip condition measurement standard (ISO 5436, type B) is recommended. 4. Conditioning and Test Conditions 4.1 Conditioning of Samples Before testing all samples have to be conditioned to equilibrium at 21 2C and 50
17、5% RH according to SAE J1767. All materials do at least require to have reached above temperature range prior to evaluation. 4.2 Test Conditions The sample and reference shall be visually checked for inhomogeneities in texture and gloss. The surface shall be free of dust, grease, contaminations or s
18、tains. All damaged areas that are no result of specific testing methods to be evaluated (e.g. scratch tests, etc.) need to be excluded from the measurements. If there is a defined direction of the test piece (e.g. up and down), the sample and the reference shall be measured in the same direction. Al
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBO110012013TEXTUREMEASUREMENTPDF