FORD FLTM BI 123-01-2005 PAINTED SHEET METAL CORROSION TEST (LABORATORY-SIMULATED ARIZONA PROVING GROUND TEST)《涂漆金属板的腐蚀试验(实验室-模拟ARIZONA实车试验场试验)》.pdf
《FORD FLTM BI 123-01-2005 PAINTED SHEET METAL CORROSION TEST (LABORATORY-SIMULATED ARIZONA PROVING GROUND TEST)《涂漆金属板的腐蚀试验(实验室-模拟ARIZONA实车试验场试验)》.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BI 123-01-2005 PAINTED SHEET METAL CORROSION TEST (LABORATORY-SIMULATED ARIZONA PROVING GROUND TEST)《涂漆金属板的腐蚀试验(实验室-模拟ARIZONA实车试验场试验)》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHODBI 123-01Date Action Revisions 2005 03 22 Revised Automatic/Manual test procedure changes, revised procedure and evaluation M. Kelly 2001 03 20 Revised Editorial no technical change A. Cockman 1996 10 02 Printed copies are uncontrolled Copyright 2005, Ford Global Technolo
2、gies, LLC Page 1 of 8 PAINTED SHEET METAL CORROSION TEST (Laboratory-Simulated Arizona Proving Ground Test) Application This test procedure is used to evaluate the relative corrosion performance of paint coating systems applied to test panels and to car body sheet metal parts. It is designed to simu
3、late the corrosive conditions of the Arizona Proving Ground (APG) Vehicle Accelerated Corrosion Test (CETP 00.00-R-311). Apparatus Required Automatic Method: Humidity Cabinet Thermotron Industries Autotechnology Company 291 Hollen Park Drive 20026 Progress Drive Holland, MI 49423 Strongsville, OH 44
4、149 (616) 392-1491 (440) 572-7800 Automated Cyclic Corrosion Test Chamber, model ACT-30-CHM-1(Thermotron) or NC series test chambers (Autotechnology Co.), or equivalent, with forced air circulation, temperature control of +/- 2 C to 65 C and relative humidity control of +/- 2% up to 90%. Manual Meth
5、od: Humidity Cabinet Thermotron Industries 291 Hollen Park Drive Holland, MI 49423 (616) 392-1491 Model No. SE-600, or equivalent with forced air circulation, temperature control of +/- 2 C to 65 C and relative humidity control of +/- 2% up to 90%. Tank Polyethylene or plastic-lined tank, with cover
6、, of sufficient size and capacity to permit the test samples to be immersed in the salt solution. For 100 x 300 mm test panels a 42 L Nalgene polyethylene tank (VWR Catalog No. 60463 - 040) is adequate. Brush Camel hair brush, flat style (VWR Catalog No. 17215-067, or equivalent). Materials Required
7、 Tape 20 mm wide, 3 M No. 898 Test Tape, or equivalent. FORD LABORATORY TEST METHODBI 123-01Printed copies are uncontrolled Copyright 2005, Ford Global Technologies, LLC Page 2 of 8 Scribing Tools Straight shank lathe cutting tool bit, 8 mm. (High speed steel, Type E, ground to a 60 included angle).
8、 Placed in a steel handle as shown in Figure 2 or a file handle as shown in Figure 3. Tool bits and wooden file handles available from: Production Tool Supply (Tip: E-6, Wooden Handle: 001 or L001) 12161 Telegraph Road Redford, MI 48239 Telephone: 1-800-366-3600 Carbide-tipped scriber available from
9、: Aircraft Specialties (#90C) G.T.S. Co (General Scriber #CM88) P.O. Box 98 12015 Telegraph Road Lapeer, MI 48446 Redford, MI 48239 Telephone: (810) 664-2981 Telephone: (313) 531-7666 James Neill Tools (Eclipse Model 225) James Neill Sheffield Ltd. Sheffield S11 8 HB U.K. Towels Paper or cloth. Sodi
10、um Chloride Reagent grade. Hydrochloric Acid Reagent grade. Sodium Hydroxide Reagent grade. Distilled or Deionized Water 10 ppm max dissolved solids per ASTM D 1888. Kaolin Powder, N.F. grade. Stop-off Lacquer Microshield Stop-off Lacquer, or equivalent. Source: Pyramid Plastic Tolber Division P.O.
11、Box 704 Hope, Arkansas 71802-0704 Telephone: (501) 777-3251 or 5759 Test Panels Panels shall be prepared in accordance to FLTM BI 120-01 (for electrocoat systems) or as indicated in the applicable Engineering Materials Specification. FORD LABORATORY TEST METHODBI 123-01Printed copies are uncontrolle
12、d Copyright 2005, Ford Global Technologies, LLC Page 3 of 8 Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5% relative humidity for not less than 24 h prior to testing and tested under the same c
13、onditions unless otherwise specified. Procedure Prepare a 5% salt solution for manual spray as follows: 1. Dissolve 53 g of sodium chloride per liter of distilled or deionized water. Sufficient test solution should be repared to allow samples to be completely immersed for the manual method. 2. Adjus
14、t the solution pH to 6.0 - 8.0 by the addition of hydrochloric acid or sodium hydroxide. 3. For the manual method, replace salt solution and clean out tank when appreciable rust accumulates in the bath and deposits on the samples, or when the pH is outside of the 6.0 - 8.0 range (do not readjust the
15、 pH). 4. (Optional) In instances of extended testing or for paint-coating systems that do not resist corrosive attack at the edges, it may be necessary to mask the edges and holes of the sample parts and the holes, edges and backs of panels with an air-dry stop-off lacquer. Such masking should be de
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBI123012005PAINTEDSHEETMETALCORROSIONTESTLABORATORYSIMULATEDARIZONAPROVINGGROUNDTEST 涂漆 金属板 腐蚀

链接地址:http://www.mydoc123.com/p-747021.html