FORD FLTM BB 113-07-2002 WELDING ACCEPTANCE TEST FOR ALUMINUM (Formerly FLTM BA 113-07)《铝的焊接验收试验 此前为FLTM BA 113-07[替代 FORD FLTM BA 113-07 FORD FLTM BA 113-07 FORD FLTM BA 113-07]》.pdf
《FORD FLTM BB 113-07-2002 WELDING ACCEPTANCE TEST FOR ALUMINUM (Formerly FLTM BA 113-07)《铝的焊接验收试验 此前为FLTM BA 113-07[替代 FORD FLTM BA 113-07 FORD FLTM BA 113-07 FORD FLTM BA 113-07]》.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BB 113-07-2002 WELDING ACCEPTANCE TEST FOR ALUMINUM (Formerly FLTM BA 113-07)《铝的焊接验收试验 此前为FLTM BA 113-07[替代 FORD FLTM BA 113-07 FORD FLTM BA 113-07 FORD FLTM BA 113-07]》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BB 113-07 Date Action Revisions 2002 08 30 Activated Formerly BA 113-07 R. Lord Printed copies are uncontrolled Page 1 of 6 Copyright 2002, Ford Global Technologies, Inc. WELDING ACCEPTANCE TEST FOR ALUMINUM Application The procedure outlined herein is a standard welding
2、 acceptance test for all aluminum alloys which are recognized or specified by the Ford Motor Company to be resistance weldable. Essentially, it is a procedure to approve the capability of a supplier or Company activity to obtain a spot weldable surface. This procedure shall constitute a method by wh
3、ich such a supplier or Company activity may become an approved supplier of spot weldable aluminum sheet and as a quality control procedure for checking consistency of weldability. Equipment Required Spot Welder This test shall be conducted on an air operated single point press type spot welder featu
4、ring a low inertia welding system and in general complying with the Resistance Welders Manufacturing Association specifications for the size of machine required. It shall be equipped with a Ford approved resistance welding control featuring 90 firing and phase shift heat control. It shall have elect
5、rode force capacities to meet the requirements of the range of material to be welded at a maximum of 550 kPa (80 psi) operating air supply line pressure. The transformer tap setting shall be selected to meet the secondary current requirements at phase heat control settings between 85 and 100 %. The
6、welder must be equipped with electrode holders conforming to Ford Drawing 2 ZU 265 and shall have furnished to it sufficient water flow capacity so that 7.6 L/min (2.0 gal/min) will flow through each electrode holder as isolated circuits from the water cooled transformer, secondary conductors, contr
7、ol panel, etc. Knife Edge Dial Caliper Brown and Sharpe Model 599-579-10 (metric model), or equivalent. Welding Electrodes Ford standard “increased water flow“ electrode caps with a radius welding face shown in Figure 1 will be used for all tests. The electrode caps must be made from Ford standard M
8、-2A107C (RWMA Class 1) material. The electrode caps, adapters and holder to be used will be found under the following identifications: Electrode Cap WC - modified as per Figure 1 Cap Adapter WB 1S Electrode Holder Assembly Drawing 2 ZU 265 FORD LABORATORY TEST METHOD BB 113-07 Page 2 of 6 Copyright
9、2002, Ford Global Technologies, Inc. Procedure Surface Preparation of Material The material submitted for approval shall be prepared according to the practice proposed to be used for production quantities. A letter shall accompany the material noting all pertinent data to identify completely the met
10、hod of preparation. A minimum of 7.5 square metres of material shall be submitted in a width equal to the maximum capability of the surface preparation equipment. The material shall be sheared in 25 x 300 mm and 100 x 300 mm pieces. Care shall be exercised to obtain pieces of each size from various
11、positions of its width. The Welding Acceptance Test shall be conducted as outlined herein. If failure occurs, the material is rejected. If the material passes the initial Welding Acceptance Test, the unused portion of the submitted material shall be stored on a rack permitting exposure of both surfa
12、ces of the sheets to normal shop atmosphere for 90 days. The Welding Acceptance Test is then repeated on the material after 90 days exposure. Approved Criteria Approval is granted when all of the following conditions are met: 1. Welding Acceptance Test on material before and after 90 days exposure t
13、o shop atmosphere produces a minimum of 2000 consecutive acceptable welds without failure. 2. Set up samples of 25 x 300 mm test strips to be free of expulsion (whiskers). 3. Indentation due to electrode pressure does not exceed 14 % of indented sheet thickness. 4. No sheet separation or buckling du
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBB113072002WELDINGACCEPTANCETESTFORALUMINUMFORMERLYFLTMBA11307 焊接 验收 试验 此前 FLTMBA11307 替代 FORDFLTMBA11307FORDFLTMBA11307FORDFLTMBA11307

链接地址:http://www.mydoc123.com/p-746899.html