FORD FLTM BA 013-03-2001 WELDING ACCEPTANCE TEST FOR ZINCROMETAL《富锌金属的焊接验收试验》.pdf
《FORD FLTM BA 013-03-2001 WELDING ACCEPTANCE TEST FOR ZINCROMETAL《富锌金属的焊接验收试验》.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BA 013-03-2001 WELDING ACCEPTANCE TEST FOR ZINCROMETAL《富锌金属的焊接验收试验》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BA 013-03 Date Action Revisions 2001 03 02 Revised Editorial no technical change A. Cockman 2000 05 22 Editorial no technical change A. Cockman 1992 07 24 Printed copies are uncontrolled Page 1 of 6 Copyright 2001, Ford Global Technologies, Inc. WELDING ACCEPTANCE TEST F
2、OR ZINCROMETAL Application This procedure is a standard welding acceptance test for one-side coated zincrometal. Equipment Required Spot Welder This test shall be conducted on an air operated single point press type spot welder featuring a low inertia welding system and in general complying with the
3、 Resistance Welders Manufacturing Association specifications for the size of machine required. It shall be equipped with a Ford approved resistance welding control featuring 90 firing and phase shift heat control. It shall have electrode force capacities to meet the requirements of the range of mate
4、rial to be tested at 550 kPa line pressure. The transformer shall be selected to meet the secondary current requirements at phase heat control settings between 85 and 100 %. The welder must be equipped with electrode holders conforming to Ford Drawing 2 ZU 265 and shall have furnished to it sufficie
5、nt water flow capacity so that two gallons per minute will flow through each electrode holder as isolated circuits from the water cooled transformer, secondary conductors, control panel, etc. Coating Thickness Tester Permascope - General Electric Model ES2J40A or equivalent. Instrumentation For the
6、current break through test - a galvanometer-type oscillograph shall be used for recording the sine wave of the secondary current. Welding Electrodes 3/4“ Ford standard design electrode caps will be used for all tests. The applicable design will be selected from Ford standard electrode cap specificat
7、ion sheet WC 1-1, Page 1. They will be manufactured from material complying with Ford Standard M1566-B, which is an RWMA Class II material. Exception to this specification will be that the minimum hardness on the welding face shall be Rockwell B 78. The electrode caps, adapters and holder to be used
8、 will be found under the following identifications: Electrode Caps WC 1A26A; WC 1A26B; WC 1A26C (select for steel thickness) Cap Adapter WB 1S Electrode Holder Assembly - Drawing 2 ZU 265. (WH103-3C) FORD LABORATORY TEST METHOD BA 013-03 Page 2 of 6 Copyright 2001, Ford Global Technologies, Inc. Con
9、ditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. Procedure Preparation of
10、 Material The material for spot weld qualification shall be representative of production practices in the ordered minimum thickness. Submission shall be in full width sheets of at least 36 inches wide. The material under test shall be supplied in full coil width. The material shall be sheared in 4 x
11、 12 inch pieces across the full trimmed width. From selected representative pieces, a number of inch x 4 inch coupons will be prepared from a material under test which are free from burrs. Care shall be exercised so as not to remove any oils used for corrosion or shipping protection. Coating thickne
12、ss on these panels shall be measured and recorded. Coating thickness shall be 0.0005 - 0.0008 inch. Current Break Through Test 1. Prepare 50 test coupons, 1 x 3 inch by metal thickness, the test coating applied on one side of each coupon. 2. Assemble 25 weld coupons by placing two coupons face-to-fa
13、ce with their coated sides outward and successively weld each assembly as specified. 3. Examine the secondary current trace of each weld for length of time in half cycles that is required to reach 90 % of full welding current at the weld schedule shown in Table 1. The zincrometal coating under these
14、 conditions shall require no more than two half cycles to reach 90 % of full welding current on all 25 welded coupons. 4. Repeat test with the coated sides face-to-face and the electrodes contacting the bare steel. 5. Break Through Tests also shall be conducted throughout the 2,000 spot weld test as
15、 described under this procedure. FORD LABORATORY TEST METHOD BA 013-03 Page 3 of 6 Copyright 2001, Ford Global Technologies, Inc. 2,000 Spot Weld Acceptance Test Coupon Size Specimens for this setup are 4 x 12 inch coupons of the actual test material. The coated sides shall be aligned to contact bot
16、h electrodes. Setting and Establishing Button Size Using 1 x 4 inch test coupons and the weld schedule shown in Table 1, two welds will be placed on their center line approximately 2 inches apart. Weld current shall be increased until the weld button diameter or metal expulsion occurs on the second
17、weld. It is expected that this condition shall be achieved in less than 25 welds and the welds made on the caps to date will not constitute part of the 2,000 spot weld test count. The diameter of the weld button as determined by the method described under “Determination of Spot Weld Diameter“ shall
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBA013032001WELDINGACCEPTANCETESTFORZINCROMETAL 金属 焊接 验收 试验 PDF

链接地址:http://www.mydoc123.com/p-746871.html