FORD FLTM AP 150-04-2001 POLYMERIC MATERIALS - EXTRACTABLES CONTENT (Replaces FLTM EU-AP 050-04)《聚合材料中的可提取物含量 替代FLTM EU-AP 050-04[替代 FORD FLTM EU-AP 050-04]》.pdf
《FORD FLTM AP 150-04-2001 POLYMERIC MATERIALS - EXTRACTABLES CONTENT (Replaces FLTM EU-AP 050-04)《聚合材料中的可提取物含量 替代FLTM EU-AP 050-04[替代 FORD FLTM EU-AP 050-04]》.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM AP 150-04-2001 POLYMERIC MATERIALS - EXTRACTABLES CONTENT (Replaces FLTM EU-AP 050-04)《聚合材料中的可提取物含量 替代FLTM EU-AP 050-04[替代 FORD FLTM EU-AP 050-04]》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD AP 150-04 Date Action Revisions 2001 01 31 Revised Editorial no technical change A. Cockman 2000 04 19 Editorial no technical change A. Cockman 1991 12 10 Printed copies are uncontrolled Page 1 of 3 Copyright 2001, Ford Global Technologies, Inc. POLYMERIC MATERIALS - EXT
2、RACTABLES CONTENT Application This test is used to determine the percent of plasticizer, oils, and/or soluble additives present in elastomeric compounds. Scope This method provides a procedure for extracting plasticizers, mineral oils, extenders, low molecular weight waxes, prelubricants as in “pres
3、wollen“ compounds, and other soluble additives typically found in polymers. It is also useful in obtaining an “oil-free“, additive-free base elastomer for cognate analysis by Thermogravimetric Analysis (TGA) and Infrared Analysis (IR). Selection of the appropriate solvent is based upon the type of p
4、olymer, requirements of the Engineering Material Specification, and/or knowledge of the solvent and anticipated solubilities of the materials to be extracted (i.e., alcohols may extract more selectively than acetone). Apparatus Required Extraction Apparatus With block tin condenser (ASTM D 297, Figu
5、re 1) Flask Erlenmeyer, 400 Ml Glass Extraction Cups Soxhlet-type or equivalent Analytical Balance Precision +/- 0.0001 g Oven ASTM E 146, Type IIB or equivalent; capable of maintaining 70 +/- 2 C Hot Plate Laboratory-extraction format, outfitted with water-cooled “block tin-type“ condensers FORD LA
6、BORATORY TEST METHOD AP 150-04 Page 2 of 3 Copyright 2001, Ford Global Technologies, Inc. Steam Bath (Located under a laboratory hood or other suitable ventilation) Materials Required Filter Paper Coarse porosity, Reeves Angel, Grade 802, 15 cm, “fluted“, or equivalent Solvent Reagent grade acetone,
7、 toluene, ethanol, diethyl or petroleum ether, chloroform, n-hexane, or any other solvent as specified by the engineering document. WARNING: Flammable, Hazardous Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2
8、 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. Procedure 1. Using a mechanical “chopper“ or scissors, cut 1 - 2 g of material into pieces approximately 2 - 3 mm x 2 - 3 mm x 2 - 3 mm. (Suggestion for the sc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMAP150042001POLYMERICMATERIALSEXTRACTABLESCONTENTREPLACESFLTMEUAP05004 聚合 材料 中的 提取物 含量 替代 FLTMEUAP05004

链接地址:http://www.mydoc123.com/p-746818.html