FORD ESB-M1L57-A2-2003 CABLE LOW TENSION VINYL INSULATED ( 85 TINNED TO BE USED WITH FORD WSS-M99P1111-A (Shown on ESB-M1L56-A2)《乙烯树脂绝缘的(85℃)锡包低压电缆 与标准FORD WSS M99P1111 A一起使用 .pdf
《FORD ESB-M1L57-A2-2003 CABLE LOW TENSION VINYL INSULATED ( 85 TINNED TO BE USED WITH FORD WSS-M99P1111-A (Shown on ESB-M1L56-A2)《乙烯树脂绝缘的(85℃)锡包低压电缆 与标准FORD WSS M99P1111 A一起使用 .pdf》由会员分享,可在线阅读,更多相关《FORD ESB-M1L57-A2-2003 CABLE LOW TENSION VINYL INSULATED ( 85 TINNED TO BE USED WITH FORD WSS-M99P1111-A (Shown on ESB-M1L56-A2)《乙烯树脂绝缘的(85℃)锡包低压电缆 与标准FORD WSS M99P1111 A一起使用 .pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATION Material Name Specification Number Date Action Revisions 2003 04 25 Revised Para 3.0 inserted; Para 3.8, 3.9, 3.10, 3.11, 3.12, 4 deleted 1993 08 13 NB00I10043054277 Released J.M. Showalter Printed copies are uncontrolled Page 1 of 7 Copyright 2003, Ford Global Te
2、chnologies, Inc. CABLE, LOW TENSION, VINYL INSULATED ( 85 C), BARE ESB-M1L56-A2 CABLE, LOW TENSION, VINYL INSULATED ( 85 C), TINNED ESB-M1L57-A2 1. SCOPE The materials defined by these specifications are stranded vinyl covered low tension cables. The vinyl covering shall be 85 C classification. 2. A
3、PPLICATION These specifications were released originally for material used for automotive electrical harnesses. 3. REQUIREMENTS 3.0 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M9
4、9P1111-A). 3.1 WIRE SIZE Shall be specified on the engineering drawing and/or release according to the SAE wire size numbers appearing in Table I. Example: # 16 gage ESB-M1L56-A2 3.2 COLOR The color of the vinyl cover shall be specified on the engineering drawing and/or release by a numerical suffix
5、 following the letter suffix of the materials desired. The numerical color coding suffixes shall correspond to the following: 0 Black 5 - Green 1 - Brown 6 - Blue 2 - Red 7 - Violet 3 - Orange 8 - Gray 4 - Yellow 9 - White or natural Example: #16 gage ESB-M1L56-A2 shall designate a stranded 16 gage,
6、 brown vinyl covered, soft or annealed bare copper conductor, corresponding to the requirements of this specification. ENGINEERING MATERIAL SPECIFICATION ESB-M1L56-A2 ESB-M1L57-A2 Page 2 of 7 Copyright 2003, Ford Global Technologies, Inc. The first color coding numerical suffix shall be the base or
7、body color of the finished cable and the second number shall designate the tracer or other auxiliary marking. 3.3 CABLE QUALITY Shall meet all of the requirements listed herein and must be equal to the original approved purchase sample. ESB-M1L56-A2 similar to M-1L17-A ESB-M1L57-A2 similar to M-1L17
8、-B 3.4 WIRE QUALITY The strands of the conductors prior to stranding shall consist of the following grades of wire: ESB-M1L56-A2: ESF-M2L1-A, soft or annealed bare copper wire ESB-M1L57-A2: ESF-M2L3-A, soft or annealed tinned copper wire 3.5 CABLE CONSTRUCTION See Tables I & II The cross sectional a
9、rea of stranded conductors shall not be less that 98% of the values specified in Table I. 3.6 INSULATION QUALITY The insulating material shall be a good grade vinyl chloride copolymer which will pass the following test requirements: The material shall adhere closely to, but strip readily from the co
10、nductors, leaving them reasonably clean and in suitable condition for soldering. Insulation thickness shall be in accordance with Table II for various wire sizes and shall be determined by measuring the diameter over the insulation, then removing the insulation and measuring the diameter of the cond
11、uctor. Half of the difference of the two measurements shall be considered as the wall thickness. 3.6.2 Mechanical Properties A test specimen of the thermoplastic insulation prepared as in the SAE J200 section on sampling shall be used. The dumbbell cut sample shall have marks placed upon it 50 mm ap
12、art. The sample shall then be stretched at the rate of 305 mm/minute. The tensile strength shall be calculated upon the original cross section of the test specimen before stretching. Testing shall be conducted at 23 +/- 2 C. Care should be exercised in cutting samples to obtain uniform cross section
13、. The properties shall be as follows: Tensile Strength, min 15.9 Mpa Elongation, min 125% ENGINEERING MATERIAL SPECIFICATION ESB-M1L56-A2 ESB-M1L57-A2 Page 3 of 7 Copyright 2003, Ford Global Technologies, Inc. 3.6.2 High Temperature Resistance Remove 25 mm of insulation from each end of a 610 mm sam
14、ple of the finished cable. The sample shall be suspended around a cylindrical mandrel having a diameter specified in Table III. Each end of the conductor shall have suspended from it, the weight shown in Table III. This condition shall be maintained for 120 h in a mechanical convection oven maintain
15、ed at a temperature of 120 +/- 2 C. When cool, the weight shall be removed from the specimen and it shall be taken off the mandrel, bent in the reverse direction around a mandrel of the diameter specified for the bend test in Table III at a rate not to exceed one complete turn/minute and then be sub
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDESBM1L57A22003CABLELOWTENSIONVINYLINSULATED85TINNEDTOBEUSEDWITHFORDWSSM99P1111ASHOWNONESBM1L56A2

链接地址:http://www.mydoc123.com/p-745195.html