1、FORD MANUFACTURING STANDARDS - EC2 - 1 NEMA SOLID STATE TIME DELAY RELAYS EC2 - 1 DECEMBER 1992 ,. . . Page 1 1. SCOPE 1.1 This Standard outlines the requirements for time delay relays which are used in “On Delay“ and “Off Delay“ applications. 1.2 Approved sources shall supply time delay relays to a
2、ccomplish the following: a) ON Delay b) OFF Delay C) ON Delay with Instantaneous Contacts d) OFF Delay with Instantaneous Contacts Time delay relays should be available either in models which are convertible from ON to OFF delay and vice versa, or in the four models listed above. If convertible the
3、means of conversion should not be readily accessible. 2. DEFINITIONS 2.1 For purposes of this Standard a time delay relay is referred to as a timer. 2.2 On Delay - Energizing of the pilot circuit starts the timing period. Upon completion of the timing period the output(s) transfer. De-energizing of
4、the pilot circuit returns the output(s) to the original state and resets the timing circuit. 2.3 Off Delay - Energizing of the pilot circuit causes immediate transfer of the output(s) and resets the timing circuit. De- energizing of the pilot circuit starts the timing period. Upon completion of the
5、timing period, the output(s) transfer, returning to the original state. 2.4 INSTANTANEOUS CONTACTS: Upon energizing of the pilot circuit, the instantaneous contacts transfer; de-energizing of the pilot circuit causes the instantaneous contacts to return to the original state. 3. GENERAL 3.1 The time
6、r shall also comply with requirements of Ford Manufacturing Standards ELX and EX1. In the event of any conflict, this Standard shall govern. FORD MANUFACTURING STANDARDS EC2 - 1 NEMA SOLID STATE TIME DELAY RELAYS DECEMBER 1992 .,:. . EC2- 1 Page 2 3.2 A manufacturer who desires to supply timers unde
7、r this Standard shall submit four identical sample units with instantaneous outputs (contacts) to Ford Motor Company for test and evaluation. These timers shall be assembled using typical production materials and techniques. 3.3 Prior to testing, the manufacturer shall also furnish electrical and me
8、chanical drawings as deemed necessary for application of the timer. A schematic circuit diagram, pictorial layout, and parts list shall be included. Standard trade identification shall be used for all components. 3.4 The Electrical Standards Subcommittee of the Ford Motor Company will determine appr
9、oved timers, Based on conformance to the requirements of this Standard and the test results. . 3.5 Any change in an approved timer will require further evaluation and approval to remain on the approved source list. Changes shall be indicated by a revision of the model or series number. The model and
10、/or series numbers shall be shown on the exterior of the package in which the timer is shipped, as well as on the timer name-plate. 3.6 The timer may include provision for mounting as an attachment to an approved machine tool relay. 3.7 The mounting space required for a timer shall not exceed a maxi
11、mum of 2.19 inches wide, by 4 inches high, by 6 inches deep. See Figure 1 for typical mounting plate, designed to occupy not more than one space on a typical relay mounting track. 3.8 3.9 Adjusting means, indicators, terminals, and mounting screws shall be accessible from the front of the timer. Ter
12、minals on the timer shall accommodate at least two type “W, 19 strand conductors, AWG 16 through 14. The conductor strands shall be clamped between two non-rotating surfaces. Saddle or pressure plates shall be captive to the terminal screw. Neither the head nor the point of the terminal screw shall
13、bear directly on the conductor strands. Screws shall no be smaller than No. 6/32, and of sufficient length so that at least two threads remain engaged when the clamping assembly is open to receive the largest conductor. 3.10 “ON“ delay timers shall include an indicating lamp which should flash durin
14、g the timing period and shall remain lighted upon expiration of the timing period. “OFF“ delay timers shall include a lamp which remains lighted until the pilot circuit is opened; it should flash while timing, and shall extinguish upon expiration of the timing period. See Figure 2 for typical sequen
15、ce of two timing operations. alternatively, two lamps of different colors may be used to indicate the timing and timed out conditions. 4. TIMING RANGE 4.1.1 A timing range of .3 to 30 seconds shall be provided. Multi- ranges are acceptable if the specified range is included. The manufacturer should
16、have other models available with time ranges such as .05 seconds to one second, and three seconds to three minutes. FIGURE 1 - Typical Mounting Plate Ill -8- 3-12 1 ! I 1 I t 3.68 - i6 Gauge Nominal ( .0598) Thick n FORD MANUFACTURING STANDARDS EC2 - 1 NE! SOLID STATE TIME DELAY RELAYS DECEMBER 1992
17、 i. EC2-1 Page 4 4.1.2 The timer delay shall be adjustable by a knob, slotted shaft, thumb-wheel switches, or other Ford approved means. All knobs shall have a brass insert for the set screw. 4.1.3 The scale may be calibrated in time units, or in relative numbers. A graduated time scale is preferred
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDEC211992NEMASOLIDSTATETIMEDELAYRELAYSNEMA 固态 延时 继电器 PDF

链接地址:http://www.mydoc123.com/p-744805.html