ETSI TS 100 783-2004 Transmission and Multiplexing (TM) Passive optical components Fibre optic fusion splices for single-mode optical fibre transmission systems for indoor and outdo.pdf
《ETSI TS 100 783-2004 Transmission and Multiplexing (TM) Passive optical components Fibre optic fusion splices for single-mode optical fibre transmission systems for indoor and outdo.pdf》由会员分享,可在线阅读,更多相关《ETSI TS 100 783-2004 Transmission and Multiplexing (TM) Passive optical components Fibre optic fusion splices for single-mode optical fibre transmission systems for indoor and outdo.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、 ETSI TS 100 783 V1.2.1 (2004-08)Technical Specification Transmission and Multiplexing (TM);Passive optical components;Fibre optic fusion splices forsingle-mode optical fibre transmission systems forindoor and outdoor applications;Common requirements and conformance testingETSI ETSI TS 100 783 V1.2.
2、1 (2004-08) 2 Reference RTS/TM-01111 Keywords connector, fibre, optical, performance, transmission ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-
3、Prfecture de Grasse (06) N 7803/88 Important notice Individual copies of the present document can be downloaded from: http:/www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between suc
4、h versions, the reference version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subjec
5、t to revision or change of status. Information on the current status of this and other ETSI documents is available at http:/portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: http:/portal.etsi.org/chaircor/ETSI_
6、support.asp Copyright Notification No part may be reproduced except as authorized by written permission. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2004. All rights reserved. DECTTM, PLUGTESTSTM and UMTSTM are Trad
7、e Marks of ETSI registered for the benefit of its Members. TIPHONTMand the TIPHON logo are Trade Marks currently being registered by ETSI for the benefit of its Members. 3GPPTM is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. ETSI ETSI TS 100
8、 783 V1.2.1 (2004-08) 3 Contents Intellectual Property Rights4 Foreword.4 1 Scope 5 2 References 5 3 Definition and abbreviations 6 3.1 Definition .6 3.2 Abbreviations .6 4 Details, measurements and performance requirements6 4.1 Visual inspection 6 4.2 Attenuation.6 4.3 Return Loss (RL)7 4.4 Vibrati
9、on (sinusoidal).7 4.5 Fibre retention 7 4.6 Torsion .8 4.7 Drop test (Impact method A)8 4.8 Cold8 4.9 Dry heat9 4.10 Damp heat (steady state) 9 4.11 Damp heat (cyclic) .10 4.12 Change of temperature .10 4.13 Corrosive atmosphere (salt mist)11 4.14 Industrial atmosphere .11 4.15 Condensation12 4.16 W
10、ater immersion 12 5 Acceptance criteria.13 5.1 Minimum sample size for qualification13 5.1.1 Qualification to minimum uniform requirements .13 5.1.2 Qualification for EN 300 019 environment classes 3.3, 3.4 and 3.5.13 5.1.3 Qualification for EN 300 019 environment class 4.113 5.2 Attenuation.14 5.3
11、Pass/fail criteria 14 History 15 ETSI ETSI TS 100 783 V1.2.1 (2004-08) 4 Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members and
12、 non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/webapp.etsi.org/
13、IPR/home.asp). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to t
14、he present document. Foreword This Technical Specification (TS) has been produced by ETSI Technical Committee Transmission and Multiplexing (TM). The present document is a revision of I-ETS 300 783. ETSI ETSI TS 100 783 V1.2.1 (2004-08) 5 1 Scope The present document specifies requirements for fusio
15、n splices to be used in single mode optical fibre telecommunications land-based (not submarine) systems. The scope covers the establishment of minimum uniform requirements for the following aspects: - optical, environmental and mechanical properties; - test conditions; - acceptance criteria. The spl
16、ices are considered to be between single fibres, between ribbon fibres and between ribbon and multiple fibres. The optical fibres which are spliced are intended to conform to IEC 60793-2-50 4. These requirements cover splices with the same single mode fibre type. In order to obtain the required func
17、tional behaviour of the fusion splices, it is necessary to follow a number of procedures for fibre preparation, fibre alignment, jointing and protection as described in ITU-T Recommendation L.12 3. All the following requirements refer to protected splices measured in a laboratory. This ES is intende
18、d to provide criteria for the assessment of splicing equipment and techniques, including the splice protector. Some users may have additional specific requirements, such as the need to verify performance at lower temperatures. These users should specify splices conforming to the basic ETSI performan
19、ce standard plus the additional tests or more severe test conditions. 2 References The following documents contain provisions which, through reference in this text, constitute provisions of the present document. References are either specific (identified by date of publication and/or edition number
20、or version number) or non-specific. For a specific reference, subsequent revisions do not apply. For a non-specific reference, the latest version applies. Referenced documents which are not found to be publicly available in the expected location might be found at http:/docbox.etsi.org/Reference. 1 E
21、TSI EN 300 019 (all parts): “Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment“. 2 IEC 61300 (all parts): “Fibre optic interconnecting devices and passive components - Basic test and measurement procedures“. 3 ITU-T Recommendation L.12: “Op
22、tical fibre joints“. 4 ETSI I-ETS 300 783: “Transmission and Multiplexing (TM); Passive optical components; Fibre optic fusion splices for single-mode optical fibre transmission systems; Common requirements and conformance testing“. ETSI ETSI TS 100 783 V1.2.1 (2004-08) 6 3 Definition and abbreviati
23、ons 3.1 Definition For the purposes of the present document, the following terms and definitions apply: fusion splice: fusion spliced fibres protected by a splice protector with fibre tails of 1,5 metres on each side of the splice protector 3.2 Abbreviations For the purposes of the present document,
24、 the following abbreviations apply: RL Return Loss 4 Details, measurements and performance requirements The performance requirements shall fulfil the ETSI environmental classes 3.1, 3.2 , 3.3 as well as environmental category U from IEC 61753-1. All measurements shall be carried out under normal roo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ETSITS1007832004TRANSMISSIONANDMULTIPLEXINGTMPASSIVEOPTICALCOMPONENTSFIBREOPTICFUSIONSPLICESFORSINGLEMODEOPTICALFIBRETRANSMISSIONSYSTEMSFORINDOORANDOUTDOPDF

链接地址:http://www.mydoc123.com/p-737524.html