ETSI TR 102 316-2004 Electromagnetic compatibility and Radio spectrum Matters (ERM) Ultra Low Power Animal Implantable Devices (ULP-AID) operating in the frequency band 315 kHz to _1.pdf
《ETSI TR 102 316-2004 Electromagnetic compatibility and Radio spectrum Matters (ERM) Ultra Low Power Animal Implantable Devices (ULP-AID) operating in the frequency band 315 kHz to _1.pdf》由会员分享,可在线阅读,更多相关《ETSI TR 102 316-2004 Electromagnetic compatibility and Radio spectrum Matters (ERM) Ultra Low Power Animal Implantable Devices (ULP-AID) operating in the frequency band 315 kHz to _1.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、 ETSI TR 102 316 V1.1.1 (2004-03)Technical Report Electromagnetic compatibilityand Radio spectrum Matters (ERM);Ultra Low Power Animal Implantable Devices (ULP-AID)operating in the frequency band 315 kHz to 600 kHz;System Reference DocumentETSI ETSI TR 102 316 V1.1.1 (2004-03) 2 Reference DTR/ERM-RM
2、-026 Keywords Inductive, MF, radio, SRD, SRDOC ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Important notice
3、Individual copies of the present document can be downloaded from: http:/www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between such versions, the reference version is the Portable Do
4、cument Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on th
5、e current status of this and other ETSI documents is available at http:/portal.etsi.org/tb/status/status.asp If you find errors in the present document, send your comment to: editoretsi.org Copyright Notification No part may be reproduced except as authorized by written permission. The copyright and
6、 the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2004. All rights reserved. DECTTM, PLUGTESTSTM and UMTSTM are Trade Marks of ETSI registered for the benefit of its Members. TIPHONTMand the TIPHON logo are Trade Marks currently being reg
7、istered by ETSI for the benefit of its Members. 3GPPTM is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. ETSI ETSI TR 102 316 V1.1.1 (2004-03) 3 Contents Intellectual Property Rights4 Foreword.4 1 Scope 5 2 References 5 3 Definitions, symbols
8、and abbreviations .6 3.1 Definitions6 3.2 Symbols6 3.3 Abbreviations .6 4 Executive summary 7 4.1 Status of the System Reference Document (SRDoc)7 4.2 Technical Issues .7 4.2.1 System description7 4.2.2 Short market information7 4.2.3 Spectrum requirement and justifications.7 4.2.4 Current regulatio
9、ns .7 4.2.5 Proposed regulation 8 4.2.6 Compatibility issues8 5 Main conclusions8 5.1 Expected timing for products to market .8 5.2 Requested ETSI and ECC actions 8 Annex A: Detailed market information .10 A.1 Range of applications .10 A.2 Market size and value.10 A.3 Traffic evaluation .10 Annex B:
10、 Technical information 11 B.1 Detailed technical description 11 B.1.1 Magnetic field requirements for inductive systems11 B.2 Technical justifications for spectrum .11 B.2.1 Field strength11 B.2.2 Frequency.12 B.2.3 Bandwidth and other radio parameters.12 B.3 Information on current version of releva
11、nt ETSI standard.12 Annex C: Expected compatibility issues 13 C.1 Coexistence studies 13 C.2 Current ITU allocations13 C.3 Sharing issues.14 History 15 ETSI ETSI TR 102 316 V1.1.1 (2004-03) 4 Intellectual Property Rights IPRs essential or potentially essential to the present document may have been d
12、eclared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, wh
13、ich is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/webapp.etsi.org/IPR/home.asp). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs n
14、ot referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This Technical Report (TR) has been produced by ETSI Technical Committee Electromagnetic compatibility and Radio spectrum Matters (ERM). ETSI ETSI
15、 TR 102 316 V1.1.1 (2004-03) 5 1 Scope The present document defines the requirements for radio frequency usage for inductive loop Ultra Low Power-Animal Implantable Devices (ULP-AID) to be used by the medical and pharmaceutical industries in medically related studies using animals for determining th
16、e efficacy and safety of drug and surgical procedures. These devices are typically simplex short range transmitters and receiver systems operating on various frequencies within the range of 315 kHz to 600 kHz. The present document includes necessary information to support the co-operation between ET
17、SI and the Electronic Communications Committee (ECC) of the European Conference of Post and Telecommunications Administrations (CEPT), including: detailed market information (see annex A); technical information (see annex B); expected compatibility issues (see annex C). 2 References For the purposes
18、 of this Technical Report (TR) the following references apply: 1 CEPT/ERC Recommendation 70-03: “Relating to the use of Short Range Devices (SRD)“. 2 ETSI EN 302 195-2 (V1.1.1): “Electromagnetic compatibility and Radio spectrum Matters (ERM); Radio equipment in the frequency range 9 kHz to 315 kHz f
19、or Ultra Low Power Active Medical Implants (ULP-AMI) and accessories; Part 2: Harmonized EN covering essential requirements of article 3.2 of the R - incorporation of the band c with the requested parameters in annex 12 of ERC Recommendation 70-03 1 by the ECC; - adoption of an ECC DECISION for this
20、 application by the ECC. ETSI ETSI TR 102 316 V1.1.1 (2004-03) 9 ETSI actions: - The spectrum parameters for inductive loop ULP-AID systems that are the subject of the present document are intended to be included as a normative annex to EN 302 195-2 2 as a revision to include the 315 kHz to 600 kHz
21、frequency band. ETSI ETSI TR 102 316 V1.1.1 (2004-03) 10Annex A: Detailed market information A.1 Range of applications ULP-AID systems find applications in small (mice), medium (rat), large (dogs) and primate animals. Small size devices are typically single channel using blood pressure, temperature,
22、 and/or biopotential sensors. Medium size devices use the same types of sensors as the small animal series, however, they can accommodate multiple sensors in 3 to 4 channel versions. Large devices can use the above sensor devices with the ability to couple multiple sensors in 2 and 3 channel version
23、s. The market for these devices includes hospitals, laboratories involved in medical research and pharmaceutical manufacturing facilities. As such, they are all within industrialized areas with high levels of existing ambients in the band. ULP-AID systems covered by the present document use transmit
24、ters designed to transmit digital information for the purpose of providing a radio link between an active animal implant and an external receiver. These implants find wide acceptance for applications such as measuring animal physiological parameters such as body temperature, blood pressure, heart ra
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ETSITR1023162004ELECTROMAGNETICCOMPATIBILITYANDRADIOSPECTRUMMATTERSERMULTRALOWPOWERANIMALIMPLANTABLEDEVICESULPAIDOPERATINGINTHEFREQUENCYBAND315KHZTO_1PDF

链接地址:http://www.mydoc123.com/p-735811.html