ETSI TR 101 557-2012 Electromagnetic compatibility and Radio spectrum Matters (ERM) System Reference document (SRdoc) Medical Body Area Network Systems (MBANSs) in the 1 785 MHz to.pdf
《ETSI TR 101 557-2012 Electromagnetic compatibility and Radio spectrum Matters (ERM) System Reference document (SRdoc) Medical Body Area Network Systems (MBANSs) in the 1 785 MHz to.pdf》由会员分享,可在线阅读,更多相关《ETSI TR 101 557-2012 Electromagnetic compatibility and Radio spectrum Matters (ERM) System Reference document (SRdoc) Medical Body Area Network Systems (MBANSs) in the 1 785 MHz to.pdf(51页珍藏版)》请在麦多课文档分享上搜索。
1、 ETSI TR 101 557 V1.1.1 (2012-02) Electromagnetic compatibility and Radio spectrum Matters (ERM); System Reference document (SRdoc); Medical Body Area Network Systems (MBANSs) in the 1 785 MHz to 2 500 MHz range Technical Report ETSI ETSI TR 101 557 V1.1.1 (2012-02) 2Reference DTR/ERM-TG30-100 Keywo
2、rds SRD, SRdoc, health ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Important notice Individual copies of the
3、 present document can be downloaded from: http:/www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF). In
4、case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the current status of this
5、 and other ETSI documents is available at http:/portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: http:/portal.etsi.org/chaircor/ETSI_support.asp Copyright Notification No part may be reproduced except as autho
6、rized by written permission. The copyright and the foregoing restriction extend to reproduction in all media. Some material contained herein is the copyright of, or has been supplied by ITU-T. European Telecommunications Standards Institute 2012. All rights reserved. DECTTM, PLUGTESTSTM, UMTSTMand t
7、he ETSI logo are Trade Marks of ETSI registered for the benefit of its Members. 3GPPTM and LTE are Trade Marks of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. GSM and the GSM logo are Trade Marks registered and owned by the GSM Association. ETSI ETSI TR 101
8、 557 V1.1.1 (2012-02) 3Contents Intellectual Property Rights 5g3Foreword . 5g3Executive summary 5g3Introduction 6g31 Scope 7g32 References 7g32.1 Normative references . 7g32.2 Informative references 7g33 Definitions, symbols and abbreviations . 10g33.1 Definitions 10g33.2 Symbols 11g33.3 Abbreviatio
9、ns . 11g34 Comments on the System Reference Document 13g34.1 Statements by ETSI Members 13g35 Presentation of the system or technology . 13g35.1 Definition and applications. 13g35.2 Societal benefits . 14g36 Market information. 15g36.1 Wireless patient monitoring - general trends 15g36.2 Wireless pa
10、tient monitoring in hospitals 16g37 Technical information 16g37.1 Detailed technical description 17g37.2 Technical parameters and implications on spectrum 17g37.2.1 Status of technical parameters 18g37.2.1.1 Current ITU and European Common Allocations . 18g37.2.1.2 Sharing and compatibility studies
11、(if any) already available 20g37.2.1.3 Sharing and compatibility issues still to be considered . 20g37.2.2 Transmitter parameters . 22g37.2.2.1 Transmitter Output Power / Radiated Power. 22g37.2.2.1a Antenna Characteristics 22g37.2.2.2 Operating Frequency . 23g37.2.2.3 Bandwidth . 23g37.2.2.4 Unwant
12、ed emissions 23g37.2.3 Receiver parameters 23g37.2.3.1 Receiver Sensitivity 23g37.2.3.2 Receiver blocking . 24g37.2.3.3 Interference criteria . 24g37.2.4 Channel access parameters . 24g37.3 Information on relevant standard(s) . 24g38 Radio spectrum request and justification . 25g38.1 Preliminary fre
13、quency band evaluation 25g38.1.1 1 785 MHz to 1 805 MHz . 25g38.1.2 2 360 MHz to 2 400 MHz . 26g38.1.3 2 400 MHz to 2 483,5 MHz (2,4 GHz generic SRD band) . 26g38.1.4 2 483,5 MHz to 2 500 MHz 27g38.2 Summary of the preliminary assessment of the frequency bands . 27g39 Regulations . 28g39.1 Current r
14、egulations . 28g39.1.1 ITU-R Radio Regulations . 28g39.1.2 European Common Allocation Table . 29g3ETSI ETSI TR 101 557 V1.1.1 (2012-02) 49.2 Proposed regulation and justification . 32g3Annex A: Detailed technical information . 34g3A.1 Technical parameters and justifications for spectrum 34g3A.1.1 Ma
15、ximum Radiated Power . 34g3A.1.1.1 Proposed Maximum Radiated Power 34g3A.1.1.2 Link Budget Analysis . 34g3A.1.1.2.1 MBANS Radio Parameters . 34g3A.1.1.2.2 Link Budget Analysis for In-hospital MBANS Applications . 35g3A.1.1.2.3 Link Budget Analysis for Home Healthcare MBANS Applications . 39g3A.1.2 E
16、mission Bandwidth. 41g3A.1.2.1 Proposed Emission Bandwidth . 41g3A.1.2.2 Technical Justification 42g3A.1.3 Total amount of Spectrum Designation 45g3A.2 RF safety considerations 49g3Annex B: Bibliography 50g3History 51g3ETSI ETSI TR 101 557 V1.1.1 (2012-02) 5Intellectual Property Rights IPRs essentia
17、l or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially
18、Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/ipr.etsi.org). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarante
19、e can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This Technical Report (TR) has been produced by ETSI Technical Committee Electromagnetic compati
20、bility and Radio spectrum Matters (ERM). ETSI ERM has in preparation a System Reference Document, TR 102 889-2 i.29 for Technical characteristics for SRD equipment for wireless industrial applications using technologies different from Ultra-WideBand (UWB). ETSI has also identified two of the candida
21、te frequency bands (2 360 MHz to 2 400 MHz and 2 483,5 MHz to 2 500 MHz) proposed for MBANSs as candidate bands for these wireless industrial applications. Both applications are license exempt SRD applications but can be both considered as critical within their environment and hence why the usual SR
22、D bands are not intended to be used by these systems. A MBANS is intended to be used mainly in hospitals, or at a later stage of the treatment, at the patients home. In any case the environment for the application is far away from the application of e.g. wireless sensors used for machine automation
23、in a factory environment. This is why these two applications in such clearly defined but totally different environments will not harmfully interfere with each other. The CEPT is requested to give due consideration on both requests simultaneously. Obviously, the possible impact on other services rema
24、ins to be studied. Executive summary MBANSs are intended to provide wireless networking of multiple body sensors and actuators used for monitoring patient physiological parameters, patient diagnosis and patient treatment, primarily in healthcare facilities as well as in other healthcare monitoring s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ETSITR1015572012ELECTROMAGNETICCOMPATIBILITYANDRADIOSPECTRUMMATTERSERMSYSTEMREFERENCEDOCUMENTSRDOCMEDICALBODYAREANETWORKSYSTEMSMBANSSINTHE1785MHZTOPDF

链接地址:http://www.mydoc123.com/p-735348.html