ETSI I-ETS 300 220-1993 Radio Equipment and Systems (RES) Short Range Devices Technical Characteristics and Test Methods for Radio Equipment to Be Used in the 25 MHz to 1 000 MHz Fo 5.pdf
《ETSI I-ETS 300 220-1993 Radio Equipment and Systems (RES) Short Range Devices Technical Characteristics and Test Methods for Radio Equipment to Be Used in the 25 MHz to 1 000 MHz Fo 5.pdf》由会员分享,可在线阅读,更多相关《ETSI I-ETS 300 220-1993 Radio Equipment and Systems (RES) Short Range Devices Technical Characteristics and Test Methods for Radio Equipment to Be Used in the 25 MHz to 1 000 MHz Fo 5.pdf(52页珍藏版)》请在麦多课文档分享上搜索。
1、ETSI I-ETS*300 220 93 e 3400855 0028753 524 INTERIM EUROPEAN TELECOMMUNICATION STANDARD I-ETS 300 220 October 1993 Source: ETSI TC-RES Reference: DI/RES-8-01 O1 UDC: 654.16 Key words: Radio, testing, short range devices Radio Equipment and Systems (RES); Short range devices Technical characteristics
2、 and test methods for radio equipment to be used in the 25 MHz to 1 O00 MHz frequency range with power levels ranging up to 500 mW ETSI European Telecommunications Standards Institute ETSI Secretariat Postal address: 06921 Sophia Antipolis Cedex - FRANCE Office address: Route des Lucioles - Sophia A
3、ntipolis - Valbonne - FRANCE Tel.: + 33 92 94 42 O0 - Fax: + 33 93 65 47 16 European Telecommunications Standards Institute 1 993. All rights reserved. No part may be reproduced except as authorised by written permission. The copyright and the foregoing restriction on reproduction extend to all medi
4、a in which the information may be embodied. ETSI I-ETS*300 220 93 m 3400855 0028754 460 Page 2 I-ETS 300 220:1993 . Whilst every care has been taken in the preparation and publication of this document, errors in content, typographical or otherwise, may occur. If you have comments concerning its accu
5、racy, please write to “ETSI Editing and Standards Approval Dept.“ at the address shown on the title page. ETSI I-ETS*300 220 93 3400855 0028755 3T7 Page 3 I-ETS 300 220:1993 Contents Foreword . 7 Introduction 8 1 Scope . 9 2 Normative references . 9 3 Definitions. symbols and abbreviations . 10 3.1
6、Definitions 10 3.2 Symbols 10 3.3 Abbreviations 11 4 General . 4.1 Presentation of equipment for testing purposes . 4.1 . 1 Choice of model for type testing 4.1.2 Definitions of alignment range and switching range 4.1.3 Definition of the categories of the alignment range (AR1 and AR21 . 4.1.4 Choice
7、 of frequencies 4.1.5 Testing of single frequency equipment of category AR1 4.1.6 Testing of single frequency equipment of category AR2 4.1.7 Testing of two frequencies equipment of category AR1 . 4.1.8 Testing of two frequency equipment of category AR2 4.1.9 Testing of multi-frequency equipment (mo
8、re than two frequencies) of 4.1.10 Testing of multi-frequency equipment (more than two frequencies) of category AR2 (switching range less than alignment range) . 4.1.1 1 Testing of multi-frequency equipment (more than two frequencies) of category AR2 (switching range equals the alignment range) 4.1.
9、12 Testing of equipment without a permanent external 50 ohm antenna connector 4.1 . 12.1 Equipment with a permanent internal 50 ohm RF connector . 4.1.12.2 Equipment with a temporary 50 ohm RF connector . . 4.2 Mechanical and electrical design . 4.2.1 General 4.2.2 Controls . 4.2.3 Transmitter shut-
10、off facility 4.2.4 Marking (equipment identification) . 4.2.5 Receiver mute or squelch . 4.3 Declarations by the applicant . 4.4 Auxiliary test equipment . 4.5 Interpretation of the measurement results . category AR1 . 11 11 11 12 12 12 12 12 13 13 13 13 14 14 14 14 14 14 14 15 15 15 15 15 15 5 Test
11、 conditions. power sources and ambient temperatures . 15 5.1 Normal and extreme test conditions . 15 5.2 External test power source . 16 5.3 Normal test conditions 16 5.3.1 Normal temperature and humidity 16 5.3.2 Normal test power source . 16 ETSI I-ETSm300 220 73 3400855 0028756 233 m Page 4 LETS
12、300 220:1993 5.3.2.1 Mains voltage . 16 5.3.2.2 Regulated lead-acid battery power sources 16 5.3.2.3 Other power sources 17 5.4 Extreme test conditions . 17 5.4.1 Extreme temperatures 17 5.4.1.1 Procedure for tests at extreme temperatures 17 5.4.1.2 Extreme temperature ranges . 18 5.4.2 Extreme test
13、 source voltages . 18 5.4.2.1 Mains voltage . 18 5.4.2.2 Regulated lead-acid battery power sources 18 5.4.2.3 Power sources using other types of batteries . 18 5.4.2.4 Other power sources 18 6 General conditions . 19 6.1 Normal test signals and test modulation 19 6.1.1 Normal test signals for analog
14、ue speech . 19 6.1.2 Normal test signais for data 19 6.2 Artificial antenna 19 6.3 Testfixture . 19 6.4 Test sites and general arrangements for radiated measurements . 20 6.5 Modes of operation of the transmitter . 20 6.6 Measuring receiver 20 7 Methods of measurement and limits for transmitter para
15、meters 7.1 Frequency error . 7.1.1 Definition 7.1.2 Method of measurement 7.1.3 Limits . 7.2 Carrier power (conducted1 . 7.2.1 Definition 7.2.2 Method of measurement 7.2.3 Limits . 7.3 Effective radiated power (radiated) . 7.3.1 Definition 7.3.2 Methods of measurement . 7.3.3 Limits . Response of th
16、e transmitter to modulation frequencies 7.4.1 Frequency deviation . 7.4.1.1 Definition 7.4.1.2 Analogue signals within the audio bandwidth . 7.4.1.3 Analogue signals above the audio bandwidth . 7.4.2 Modulation depth . 7.4.2.1 Definition 7.4.2.2 Analogue signals within the audio bandwidth . 7.4.2.3
17、Analogue signals above the audio bandwidth . 7.5 Adjacent channel power . 7.5.1 Definition 7.5.2 Method of measurement receiver . 7.5.3 Limits . 7.6.1 Definition 7.6.2 Method of measurement 7.6.3 Limits . 7.4 7.5.2.1 Method of measurement using a power measuring 7.6 Range of modulation bandwidth for
18、 wide band equipment (25 kHz) . 7.7 Spurious emissions 21 21 21 21 22 22 22 22 23 23 23 23 24 25 25 25 25 26 27 27 28 28 29 29 30 30 31 31 31 31 32 32 - ETSI I-ETS*300 220 93 3400855 0028757 17T Page 5 I-ETS 300 2201993 7.7.1 Definition 32 7.7.2 Method of measuring the power level in a specified loa
19、d. subclause 7.7.1 a.) . 32 7.7.3 Method of measuring the effective radiated power. subclause 7.7.1 a.) 33 7.7.4 Method of measuring the effective radiated power. subclause 7.7.1 b) 34 7.7.5 Limits . 34 8 Methods of measurement and limits for receiver parameters 34 8.1 Spurious radiation . 34 8.1.1
20、Definition 34 8.1.2 Method of measuring the power level in a specified load. subclause 8.1.1 a.) . 35 8.1.3 Method of measuring the effective radiated power. subclause 8.1 . 1 a.) 35 8.1.4 Method of measuring the effective radiated power. subclause 8.1.1 b) 36 8.1.5 Limits . 36 9 Measurement uncerta
21、inty 36 Annex A (informative): Defined applications using LETS 300 220 . 37 A.l Application: Low power devices 37 A.l.l General 37 A.1.2 Definition . 37 A . 1.3 Technical parameters . 37 Annex B (normative): Radiated measurements 38 B.l Test sites and general arrangements for measurements involving
22、the use of radiated fields . 38 B.l.l Outdoor test site 38 8.1.1.1 Test support for body worn equipment 39 B . 1.1.2 Standard position . 39 B.1.2 Test antenna 39 B.1.3 Substitution antenna . 40 B . 1.4 Optional additional indoor site . 40 B.2 Guidance on the use of radiation test sites 41 8.2.1 Meas
23、uring distance 41 B.2.2 Test antenna 41 B.2.3 Substitution antenna . 41 8.2.4 Artificial antenna 42 6.2.5 Auxiliary cables . 42 B.3 Further optional alternative indoor test site using an anechoic chamber . 42 B.3.1 Example of the construction of a shielded anechoic chamber . 42 6.3.2 Influence of pa
24、rasitic reflections in anechoic chambers 43 B.3.3 Calibration of the shielded RF anechoic chamber 43 Annex C (normative): . 45 Specifications for adjacent channel power measurement arrangements . 45 C.l Power measuring receiver specification . 45 ETSI I-ETS*300 220 93 W 3400855 0028758 006 Page 6 LE
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ETSIIETS3002201993RADIOEQUIPMENTANDSYSTEMSRESSHORTRANGEDEVICESTECHNICALCHARACTERISTICSANDTESTMETHODSFORRADIOEQUIPMENTTOBEUSEDINTHE25MHZTO1000MHZFO5PDF

链接地址:http://www.mydoc123.com/p-734230.html