ETSI GS OSG 001-2012 Open Smart Grid Protocol (OSGP) (V1 1 1)《开放智能电网协议(OSGP)(版本1 1 1)》.pdf
《ETSI GS OSG 001-2012 Open Smart Grid Protocol (OSGP) (V1 1 1)《开放智能电网协议(OSGP)(版本1 1 1)》.pdf》由会员分享,可在线阅读,更多相关《ETSI GS OSG 001-2012 Open Smart Grid Protocol (OSGP) (V1 1 1)《开放智能电网协议(OSGP)(版本1 1 1)》.pdf(256页珍藏版)》请在麦多课文档分享上搜索。
1、 ETSI GS OSG 001 V1.1.1 (2012-01) Open Smart Grid Protocol (OSGP) Disclaimer This document has been produced and approved by the Open Smart Grid (OSG) ETSI Industry Specification Group (ISG) and represents the views of those members who participated in this ISG. It does not necessarily represent the
2、 views of the entire ETSI membership. Group Specification ETSI ETSI GS OSG 001 V1.1.1 (2012-01) 2Reference DGS/OSG-001 Keywords protocol, smart meter ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742
3、 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Important notice Individual copies of the present document can be downloaded from: http:/www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of exist
4、ing or perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present docum
5、ent should be aware that the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at http:/portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the follo
6、wing services: http:/portal.etsi.org/chaircor/ETSI_support.asp Copyright Notification No part may be reproduced except as authorized by written permission. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2012. All right
7、s reserved. DECTTM, PLUGTESTSTM, UMTSTMand the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members. 3GPPTM and LTETMare Trade Marks of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. GSM and the GSM logo are Trade Marks registered and o
8、wned by the GSM Association. ETSI ETSI GS OSG 001 V1.1.1 (2012-01) 3Contents Intellectual Property Rights 11g3Foreword . 11g31 Scope 12g32 References 12g32.1 Normative references . 13g32.2 Informative references 13g33 Definitions and abbreviations . 13g33.1 Definitions 13g33.2 Abbreviations . 16g34
9、OSGP operation overview 17g35 OSGP network formation and maintenance . 19g35.1 Discovery Protocol . 19g35.2 Discovery Domain 20g35.3 ADD Proxy Message 20g35.4 ATM Query ID . 20g35.5 ATM Respond to Query . 22g35.6 Signal Strength Values . 22g35.7 Examples 22g35.8 Fast Commission Message (FCM) . 23g35
10、.8.1 Overview 23g35.8.2 FCM message and response description . 23g36 OSGP Device data representation 24g36.1 General overview . 24g36.2 Data Types 25g36.3 Pending tables 26g36.4 Value Control Identifiers (VCI) . 27g36.5 Value 27g36.6 Register Naming Convention . 27g36.7 Table and Procedure Naming Co
11、nventions 27g36.8 Interface Change Alarm (ICA NACK) . 28g37 Security. 28g37.1 OMA key 28g37.2 OSGP Authentication . 29g37.3 OSGP Encryption . 30g37.4 Hardware Lock . 30g38 Device Functional Description for the case the OSGP device is an electric power metering device 31g38.1 General . 31g38.2 Time-O
12、f Use Calendar (Optional) 31g38.2.1 Manual Override Options (optional) . 32g38.2.2 Over Power Threshold Tariff (optional) . 32g38.3 Clock Adjustment (mandatory) 33g38.3.1 Absolute Time Synch 33g38.3.2 Clock Adjustment by Delta . 33g38.4 Billing Functions 33g38.4.1 Self-Reads (mandatory) 33g38.4.2 To
13、tal Energy (optional) . 34g38.4.3 On-Demand Reads of Current Billing Register Values (mandatory) 34g38.5 Load Profile (mandatory) . 34g38.5.1 Use case: Reading Load Profile Data . 34g38.5.2 Use case: Parsing M-Bus Load Profile Data . 35g38.5.2.1 M-Bus Data Types and ET57 35g3ETSI ETSI GS OSG 001 V1.
14、1.1 (2012-01) 48.5.2.2 Load Profile Poll Rate . 36g38.5.2.3 Time Stamping 36g38.5.3 Load Profile Unread Entries Alarm 37g38.6 Self-Test (Alarms, Error Codes) (optional) 37g38.7 Pulse Inputs (optional) 37g38.8 Power Quality (optional) 37g38.8.1 Functional Description 37g38.9 Display (optional) . 39g3
15、8.9.1 Display Sources List (optional) 39g38.9.2 Display Configuration (optional) 41g38.9.3 Error Codes Configuration (optional) . 41g38.9.4 Simulated Wheel Rotation Configuration (optional) 41g38.9.5 Disconnect Configuration (optional 41g38.9.6 CT and VT Ratios (optional) 42g38.9.7 Firmware Version
16、on Power-Up (optional) 42g38.9.8 PLC signal quality Icons (optional) 42g38.9.9 Scheduled Display Messages (optional) . 42g38.10 Load Disconnect Contactor (optional) . 42g38.10.1 Maximum Power and Current Level Thresholds 43g38.10.1.1 Changing the Devices Maximum Power Level Threshold . 43g38.10.1.2
17、Changing the Devices Maximum Current Level Threshold . 44g38.10.1.3 Choosing Power or Current (optional) 44g38.10.2 Prepaid Metering (optional) 44g38.10.3 Local Manual Control (optional) 45g38.10.4 Load Contactor Remote Control (optional) 45g38.11 Control Relay (optional) . 45g38.11.1 Control Relay
18、Randomization. 46g38.11.2 Time-Based Control Relay Calendar 46g38.11.3 Remote Control . 46g38.12 History Log (optional) 47g38.12.1.1 Critical Events (optional) 47g38.12.1.2 Critical Event Categories 47g38.12.1.3 Critical Event Bitmasks . 47g38.12.1.3.1 Example Critical Event Bitmask . 48g38.13 One-T
19、ime Reads (optional) 49g38.14 Group Broadcasts (optional). 49g38.15 Demand Metering (optional) 50g38.15.1 Demand Values (optional) 50g38.15.1.1 Present Demand 50g38.15.1.2 Previous Demand 51g38.15.1.3 Maximum (Peak) Demand 51g38.15.1.4 Coincident Sources 51g38.15.1.5 Cumulative Demand 51g38.15.1.6 C
20、ontinuous Cumulative Demand 51g38.15.1.7 Demand Reset . 51g38.15.1.8 Historical Demand Reset Log . 52g38.15.1.9 Initializing Demand Metering . 52g38.15.1.10 Reconfiguration . 52g38.16 Test Mode . 52g38.17 MEP Device Overview . 53g38.17.1 Downlink Data Transfer . 53g38.17.1.1 Reading Non-Urgent Data
21、. 53g38.17.1.2 Reading and Processing On-Demand Requests 55g38.17.2 Uplink Data Transfer 57g38.17.2.1 Responding to a Scheduled Read Request (With and Without Alarms) . 57g38.17.2.2 Responding to an On-Demand Read Request (With and Without Alarms) 59g38.17.2.3 Posting Unsolicited Non-urgent Data (Wi
22、th and Without Alarms). 61g38.17.2.4 Posting Unsolicited Urgent Data . 62g38.17.2.5 Posting Alarms Only . 63g38.18 M-Bus Device support (optional) . 64g38.18.1 Billing Data Collection . 64g38.18.1.1 On-Demand Reads for M-Bus Devices . 64g3ETSI ETSI GS OSG 001 V1.1.1 (2012-01) 58.18.1.2 Scheduled Rea
23、ds for M-Bus Devices 65g38.18.1.3 One-Time-Reads for M-Bus Devices 66g38.18.1.4 Power Outage Data-Read Interruptions 66g38.18.2 Auto-discovery . 67g38.18.3 Device Removal 67g38.18.4 M-Bus Status and Alarms . 67g38.19 Compatibility Settings (mandatory) . 67g39 Basic OSGP services 68g39.1 Matching of
24、requests and responses . 68g39.2 Buffer sizing restrictions: . 68g39.3 Full Table Read service 68g39.3.1 Request . 68g39.3.2 Full Read Response 69g39.4 Full Table write service 69g39.4.1 Request . 69g39.4.2 Response. 70g39.5 Partial table read . 70g39.5.1 Request . 70g39.5.2 Response. 70g39.6 Partia
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ETSIGSOSG0012012OPENSMARTGRIDPROTOCOLOSGPV111 开放 智能 电网 协议 OSGP 版本 111 PDF

链接地址:http://www.mydoc123.com/p-733425.html