ETSI GS OEU 002-2015 Operational energy Efficiency for Users (OEU) Energy Consumption Measurement of Operational Technical Equipment of Copper and Optical Fixed Access (V1 1 1)《用户的.pdf
《ETSI GS OEU 002-2015 Operational energy Efficiency for Users (OEU) Energy Consumption Measurement of Operational Technical Equipment of Copper and Optical Fixed Access (V1 1 1)《用户的.pdf》由会员分享,可在线阅读,更多相关《ETSI GS OEU 002-2015 Operational energy Efficiency for Users (OEU) Energy Consumption Measurement of Operational Technical Equipment of Copper and Optical Fixed Access (V1 1 1)《用户的.pdf(25页珍藏版)》请在麦多课文档分享上搜索。
1、 ETSI GS OEU 002 V1.1.1 (2015-06) Operational energy Efficiency for Users (OEU); Energy Consumption Measurement of Operational Technical Equipment of Copper and Optical Fixed Access Disclaimer This document has been produced and approved by the Operational energy Efficiency for Users (OEU) ETSI Indu
2、stry Specification Group (ISG) and represents the views of those members who participated in this ISG. It does not necessarily represent the views of the entire ETSI membership. GROUP SPECIFICATION ETSI ETSI GS OEU 002 V1.1.1 (2015-06)2 Reference DGS/OEU-002 Keywords BROADBAND, DSLAM, Energy Efficie
3、ncy, KPI, MSAN, Network Measurement, Network monitoring, OLT, USER ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/
4、88 Important notice The present document can be downloaded from: http:/www.etsi.org/standards-search The present document may be made available in electronic versions and/or in print. The content of any electronic and/or print versions of the present document shall not be modified without the prior
5、written authorization of ETSI. In case of any existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat. Users of the present doc
6、ument should be aware that the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at http:/portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the fol
7、lowing services: https:/portal.etsi.org/People/CommiteeSupportStaff.aspx Copyright Notification No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm except as authorized by written permission of ETSI. The content of the PDF
8、 version shall not be modified without the written authorization of ETSI. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2015. All rights reserved. DECTTM, PLUGTESTSTM, UMTSTMand the ETSI logo are Trade Marks of ETSI r
9、egistered for the benefit of its Members. 3GPPTM and LTE are Trade Marks of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. GSM and the GSM logo are Trade Marks registered and owned by the GSM Association. ETSI ETSI GS OEU 002 V1.1.1 (2015-06)3 Contents Intell
10、ectual Property Rights 4g3Foreword . 4g3Modal verbs terminology 4g3Introduction 4g31 Scope 5g32 References 6g32.1 Normative references . 6g32.2 Informative references 6g33 Definitions, symbols and abbreviations . 7g33.1 Definitions 7g33.2 Symbols 7g33.3 Abbreviations . 7g34 On-field KPI . 8g35 Key p
11、arameters to evaluate the energy consumption . 8g35.1 Generality . 8g35.2 DSL impacting parameters . 9g35.3 FTTH impacting parameters. 10g35.4 Some words on the error and uncertainty . 10g36 MSAN in DSLAM modelling 11g36.1 Coefficients and variables 11g36.1.1 Coefficients . 11g36.1.2 Variables. 13g3
12、6.1.3 Parameters, coefficients and variables 13g36.2 DSL_power KPI definition. 14g36.3 Operational values and KPI 14g37 The MSAN in OLT modelling . 15g37.1 Coefficients and variables 15g37.1.1 Coefficients . 15g37.1.2 Variables. 16g37.1.3 Parameters, coefficients and variables 17g37.2 GPON_power KPI
13、 definition . 17g37.3 Further remarks 18g38 Methods to obtain the variables and coefficients values 18g38.1 Coefficients 18g38.2 Variables. 19g39 Towards indirect KPIs 19g39.1 Network KPI (example with FAN modelling) . 19g39.2 Proposal on Energy Efficiency (EER) KPI 20g3Annex A (informative): DSL Op
14、erational examples . 21g3Annex B (informative): GPON operational example 23g3History 25g3ETSI ETSI GS OEU 002 V1.1.1 (2015-06)4 Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential I
15、PRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are a
16、vailable on the ETSI Web server (http:/ipr.etsi.org). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which a
17、re, or may be, or may become, essential to the present document. Foreword This Group Specification (GS) has been produced by ETSI Industry Specification Group (ISG) Operational energy Efficiency for Users (OEU). Modal verbs terminology In the present document “shall“, “shall not“, “should“, “should
18、not“, “may“, “need not“, “will“, “will not“, “can“ and “cannot“ are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of provisions). “must“ and “must not“ are NOT allowed in ETSI deliverables except when used in direct citation. Introduction Fu
19、rther to the 1997 Kyoto protocol i.6, the European Commission issued Directives in order to improve the energy consumption of telecommunication services. Fixed Broadband Access constitutes one of the most important ICT areas of energy consumption. Therefore suppliers and users of information and com
20、munication technology (ICT) equipment are obliged to implement “Green“ tools (meters, indicators) to monitor the energy efficiency of their networks. The main target of ETSI ISG OEU is the development of the present document defining appropriate energy consumption measurements for operational techni
21、cal equipment of copper and optical access loop as well as technical Measurement Key Performance Indicators (KPIs) to be used for operational Fixed Access Network. The present document has been developed by ISG OEU members and is supported by the CTO Alliance/CRIP to define the most efficient tools.
22、 It is expected that the present document will influence the development of new specifications on energy consumption, measurements of operational technical equipment of copper and optical fixed access under the responsibility of ETSI TC EE. Several standards and technical documents have been taken i
23、nto account during the development of the present document including EC Mandate M/462 i.1, ETSI ES 203 215 V1.2.1 1, JCGM 100:2008 2, ETSI TS 105 174-1 i.2, ETSI TS 105 174-4-1 i.3, ETSI TS 105 174-5-1 i.4 EC DG JRC Code of Conduct for Broadband Networks i.5, and Kyoto Protocol i.6. ETSI ETSI GS OEU
24、 002 V1.1.1 (2015-06)5 1 Scope The present document proposes Key Performance Indicators (KPI) applicable by vendors in laboratories or by operators in operational situations. The scope of the present document is exclusively dealing with the Multi-Service Access Node MSAN, configured for both Fiber t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ETSIGSOEU0022015OPERATIONALENERGYEFFICIENCYFORUSERSOEUENERGYCONSUMPTIONMEASUREMENTOFOPERATIONALTECHNICALEQUIPMENTOFCOPPERANDOPTICALFIXEDACCESSV111

链接地址:http://www.mydoc123.com/p-733409.html