《ETSI ES 202 336-1-2011 Environmental Engineering (EE) Monitoring and Control Interface for Infrastructure Equipment (Power Cooling and Building Environment Systems used in Telecomm_1.pdf》由会员分享,可在线阅读,更多相关《ETSI ES 202 336-1-2011 Environmental Engineering (EE) Monitoring and Control Interface for Infrastructure Equipment (Power Cooling and Building Environment Systems used in Telecomm_1.pdf(80页珍藏版)》请在麦多课文档分享上搜索。
1、 ETSI ES 202 336-1 V1.2.1 (2011-07)ETSI Standard Environmental Engineering (EE);Monitoring and Control Interface for Infrastructure Equipment(Power, Cooling and Building Environment Systems used inTelecommunication Networks)Part 1: Generic Interfacefloppy3ETSI ETSI ES 202 336-1 V1.2.1 (2011-07)2Refe
2、rence RES/EE-02039-1 Keywords control, interface, management, power, system ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06
3、) N 7803/88 Important notice Individual copies of the present document can be downloaded from: http:/www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between such versions, the referen
4、ce version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change
5、 of status. Information on the current status of this and other ETSI documents is available at http:/portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: http:/portal.etsi.org/chaircor/ETSI_support.asp Copyright N
6、otification No part may be reproduced except as authorized by written permission. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2011. All rights reserved. DECTTM, PLUGTESTSTM, UMTSTMand the ETSI logo are Trade Marks o
7、f ETSI registered for the benefit of its Members. 3GPPTM and LTE are Trade Marks of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. GSM and the GSM logo are Trade Marks registered and owned by the GSM Association. ETSI ETSI ES 202 336-1 V1.2.1 (2011-07)3Conten
8、ts Intellectual Property Rights 6g3Foreword . 6g31 Scope 7g32 References 7g32.1 Normative references . 7g32.2 Informative references 8g33 Definitions and abbreviations . 9g33.1 Definitions 9g33.2 Abbreviations . 11g34 Monitoring and Control (M Essential, or potentially Essential, IPRs notified to ET
9、SI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/ipr.etsi.org). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the exist
10、ence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This ETSI Standard (ES) has been produced by ETSI Technical Committee Environmental Engineering (EE). The present document is
11、part 1 of a multi-part deliverable covering power, cooling and building environment systems control and monitoring guidance, as identified below: Part 1: “Generic Interface“; Part 2: “DC power system control and monitoring information model“; Part 3: “AC UPS power system control and monitoring infor
12、mation model“; Part 4: “AC distribution power system control and monitoring information model“; Part 5: “AC diesel back-up generator system control and monitoring information model“; Part 6: “Air conditioning system control and monitoring information model“; Part 7: “Other utilities system control a
13、nd monitoring information model“; Part 8: “Remote power feeding system control and monitoring information model“; Part 9: “Alternative power systems control and monitoring information model“; Part 10: “AC inverter power system control and monitoring information model“. ETSI ETSI ES 202 336-1 V1.2.1
14、(2011-07)71 Scope The present document applies to monitoring and control of Infrastructure Environment i.e. power, cooling and building environment systems for telecommunication centres and access network locations. Interoperability of heterogeneous management interfaces and systems with multi-vendo
15、r equipment is the key issue. The present document gives a general approach from equipment to management system. The multi-part deliverable is composed of a generic core part (the present document) and several specific parts for equipment category (ES 202 336-2 and following 15 and i.14). The core d
16、ocument defines: The site equipment map and its division in functional subsets e.g. DC system which introduces part 2 and following parts of this multi-part deliverable. The generic set of exchanged information required at the interface of equipment, which is instanced for each equipment subset in p
17、art 2 and following parts of this multi-part deliverable. The minimum requirement for network architecture allowing some compatibility with old existing interface and the mechanism to exchange data between network element. The data interface protocol for remote or local site management (Machine to M
18、achine Interface MMI) and Human Machine Interface HMI for monitoring and controlling. Recommendations for sure management network such as dependability, data back-up, data coherence and synchronization all along the management network, response time, fault detection and partial service in case of fa
19、ilure. 2 References References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the reference document (including any amendments
20、) applies. Referenced documents which are not found to be publicly available in the expected location might be found at http:/docbox.etsi.org/Reference. NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee their long term validity. 2.1 Normat
21、ive references The following referenced documents are necessary for the application of the present document. 1 ETSI ETS 300 132-1: “Equipment Engineering (EE); Power supply interface at the input to telecommunications equipment; Part 1: Operated by alternating current (AC) derived from direct curren
22、t (DC) sources“. 2 ETSI EN 300 132-2: “Environmental Engineering (EE); Power supply interface at the input to telecommunications equipment; Part 2: Operated by direct current (DC)“. 3 ETSI EN 300 132-3: “Environmental Engineering (EE); Power supply interface at the input to telecommunications equipm
23、ent; Part 3: Operated by rectified current source, alternating current source or direct current source up to 400 V“. 4 ETSI EN 302 099: “Environmental Engineering (EE); Powering of equipment in access network“. 5 ITU-T Recommendation M.3010: “Principles for a Telecommunications management network“.
24、ETSI ETSI ES 202 336-1 V1.2.1 (2011-07)86 ITU-T Recommendation M.3100: “Generic network information model“. 7 ITU-T Recommendation X.733: “Information technology - Open Systems Interconnection - Systems Management: Alarm reporting function“. 8 IEC 60839-5-4: “Alarm systems - Part 5: Requirements for
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ETSIES20233612011ENVIRONMENTALENGINEERINGEEMONITORINGANDCONTROLINTERFACEFORINFRASTRUCTUREEQUIPMENTPOWERCOOLINGANDBUILDINGENVIRONMENTSYSTEMSUSEDINTELECOMM_1PDF

链接地址:http://www.mydoc123.com/p-730904.html