ETSI EN 300 330-2-2015 Electromagnetic compatibility and Radio spectrum Matters (ERM) Short Range Devices (SRD) Radio equipment in the frequency range 9 kHz to 25 MHz and inductive_1.pdf
《ETSI EN 300 330-2-2015 Electromagnetic compatibility and Radio spectrum Matters (ERM) Short Range Devices (SRD) Radio equipment in the frequency range 9 kHz to 25 MHz and inductive_1.pdf》由会员分享,可在线阅读,更多相关《ETSI EN 300 330-2-2015 Electromagnetic compatibility and Radio spectrum Matters (ERM) Short Range Devices (SRD) Radio equipment in the frequency range 9 kHz to 25 MHz and inductive_1.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、 ETSI EN 300 330-2 V1.6.1 (2015-03) Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Part 2: Harmonized EN covering the essential requir
2、ements of article 3.2 of the R Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/ipr.etsi.org). Pursuant to the ETSI IPR Policy, no investigation, includin
3、g IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This Harmonized European Standard (EN)
4、has been produced by ETSI Technical Committee Electromagnetic compatibility and Radio spectrum Matters (ERM). For non EU countries the present document may be used for regulatory (Type Approval) purposes. The present document has been produced by ETSI in response to mandate M/284 issued from the Eur
5、opean Commission under Directive 98/34/EC i.1 as amended by Directive 98/48/EC i.7. The title and reference to the present document are intended to be included in the publication in the Official Journal of the European Union of titles and references of Harmonized Standard under the Directive 1999/5/
6、EC i.2. See article 5.1 of Directive 1999/5/EC i.2 for information on presumption of conformity and Harmonized Standards or parts thereof the references of which have been published in the Official Journal of the European Union. The requirements relevant to Directive 1999/5/EC i.2 are summarized in
7、annex A. The present document is part 2 of a multi-part deliverable covering Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz, as identif
8、ied below: Part 1: “Technical characteristics and test methods“; Part 2: “Harmonized EN covering the essential requirements of article 3.2 of the R and 2) inductive loop transmitters operating from 9 kHz to 30 MHz including Radio Frequency Identification (RFID) and EAS equipments operating in LF and
9、 HF ranges and for radio equipment including wireless power transfer (WPT) function in the same frequency range; 3) receivers of systems as defined by bullets 1 and 2; 4) these radio equipment types are capable of operating in the permitted frequency bands within the 9 kHz to 30 MHz range as specifi
10、ed in table 1: - either with a Radio Frequency (RF) output connection and dedicated antenna or with an integral antenna; - for all types of modulation; - with or without speech. Table 1 shows a list of the frequency bands as designated to Short Range Devices by some European Commission Decisions and
11、 the CEPT/ERC/REC 70-03 i.5 as known at the date of publication of the present document. Table 1: Frequency bands designated to Short Range Devices within 9 kHz to 30 MHz Frequency Bands/frequencies Applications Transmit and Receive 9 kHz to 90 kHz Inductive devices, Generic use Transmit and Receive
12、 90 kHz to 119 kHz Inductive devices, Generic use Transmit and Receive 119 kHz to 140 kHz Inductive devices, Generic use Transmit and Receive 140 kHz to 148,5 kHz Inductive devices, Generic use Transmit and Receive 148,5 kHz to 5 MHz Inductive devices, Generic use Transmit and Receive 400 kHz to 600
13、 kHz RFID only Transmit and Receive 5 kHz to 30 MHz Inductive devices, Generic use Transmit and Receive 3 155 kHz to 3 400 kHz Inductive devices, Generic use Transmit and Receive 4 234 kHz Inductive devices, Railway applications Transmit and Receive 4 516 kHz Inductive devices, Railway applications
14、Transmit and Receive 6 765 kHz to 6 795 kHz Inductive devices, Generic use Transmit and Receive 7 400 kHz to 8 800 kHz Inductive devices, Generic use Transmit and Receive 10 200 kHz to 11 000 kHz Inductive devices, Generic use Transmit and Receive 11 810 kHz to 15 310 kHz RFID only Transmit and Rece
15、ive 12,5 MHz to 20 MHz Inductive devices, Wireless healthcare Transmit and Receive 13,553 MHz to 13,567 MHz Inductive devices, Generic use Transmit and Receive 26,957 MHz to 27,283 MHz Inductive devices, Generic use Transmit and Receive 27,095 MHz Inductive devices, Railway applications NOTE 1: It s
16、hould be noted that table 1 represents the most widely implemented position within the European Union and the CEPT countries, but it should not be assumed that all designated bands are available in all countries. NOTE 2: In addition, it should be noted that other frequency bands may be available in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ETSIEN30033022015ELECTROMAGNETICCOMPATIBILITYANDRADIOSPECTRUMMATTERSERMSHORTRANGEDEVICESSRDRADIOEQUIPMENTINTHEFREQUENCYRANGE9KHZTO25MHZANDINDUCTIVE_1PDF

链接地址:http://www.mydoc123.com/p-728186.html