ETSI EN 300 132-3-2003 Environmental Engineering (EE) Power supply interface at the input to telecommunications equipment Part 3 Operated by rectified current source alternating cu.pdf
《ETSI EN 300 132-3-2003 Environmental Engineering (EE) Power supply interface at the input to telecommunications equipment Part 3 Operated by rectified current source alternating cu.pdf》由会员分享,可在线阅读,更多相关《ETSI EN 300 132-3-2003 Environmental Engineering (EE) Power supply interface at the input to telecommunications equipment Part 3 Operated by rectified current source alternating cu.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、 ETSI EN 300 132-3 V1.2.1 (2003-08)European Standard (Telecommunications series) Environmental Engineering (EE);Power supply interface at the input totelecommunications equipment;Part 3: Operated by rectified current source,alternating current source ordirect current source up to 400 VETSI ETSI EN 3
2、00 132-3 V1.2.1 (2003-08) 2 Reference DEN/EE-02001-3 Keywords environment, interface, power supply ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-
3、Prfecture de Grasse (06) N 7803/88 Important notice Individual copies of the present document can be downloaded from: http:/www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between suc
4、h versions, the reference version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subjec
5、t to revision or change of status. Information on the current status of this and other ETSI documents is available at http:/portal.etsi.org/tb/status/status.asp If you find errors in the present document, send your comment to: editoretsi.org Copyright Notification No part may be reproduced except as
6、 authorized by written permission. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2003. All rights reserved. DECTTM, PLUGTESTSTM and UMTSTM are Trade Marks of ETSI registered for the benefit of its Members. TIPHONTMand
7、 the TIPHON logo are Trade Marks currently being registered by ETSI for the benefit of its Members. 3GPPTM is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. ETSI ETSI EN 300 132-3 V1.2.1 (2003-08) 3 Contents Intellectual Property Rights4 Forew
8、ord.4 1 Scope 5 2 References 5 3 Definitions and abbreviations.6 3.1 Definitions6 3.2 Abbreviations .6 4 Interface A37 5 Requirements7 5.1 Nominal voltage .7 5.2 Normal service voltages at interface A3.8 5.3 Nominal frequencies.8 5.4 Abnormal service voltage ranges at interface A3.8 5.4.1 Abnormal s
9、ervice voltage under steady-state conditions8 5.4.2 Voltage dips, short interruptions and transients8 5.5 Supply protection .9 5.6 Maximum current drain9 5.7 Surge current on connection to interface A3 9 5.7.1 Limits9 5.7.2 Measurements .10 6 Earthing and bonding .11 7 Electrical safety requirements
10、 11 8 EMC requirements .11 Annex A (informative): Power supply considerations.12 A.1 Possible power supply configurations12 A.2 Supply voltage waveforms .13 Annex B (informative): Identification of interface A3 14 Annex C (informative): Calculation of the extreme voltage nominal values at interface
11、A3 15 Annex D (informative): Calculation of the extreme voltage nominal values at interface A3 in the case of using other nominal voltage .16 Annex E (informative): Bibliography.17 History 18 ETSI ETSI EN 300 132-3 V1.2.1 (2003-08) 4 Intellectual Property Rights IPRs essential or potentially essenti
12、al to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified
13、 to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/webapp.etsi.org/IPR/home.asp). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be
14、 given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This European Standard (Telecommunications series) has been produced by ETSI Technical Committee Environ
15、mental Engineering (EE). The present document concerns the requirements for the interface between telecommunications equipment and its power supply and includes requirements relating to its stability and measurement. Various other references and detailed measurement and test arrangements are contain
16、ed in informative annexes. The present document is part 3 of a multi-part deliverable covering Environmental Engineering (EE); Power supply interface at the input to telecommunications equipment, as identified below: Part 1: “Operated by alternating current (ac) derived from direct current (dc) sour
17、ces“; Part 2: “Operated by direct current (dc)“; Part 3: “Operated by rectified current source, alternating current source or direct current source up to 400 V“. National transposition dates Date of adoption of this EN: 25 July 2003 Date of latest announcement of this EN (doa): 31 October 2003 Date
18、of latest publication of new National Standard or endorsement of this EN (dop/e): 30 April 2004 Date of withdrawal of any conflicting National Standard (dow): 30 April 2004 ETSI ETSI EN 300 132-3 V1.2.1 (2003-08) 5 1 Scope The present document contains requirements for: the output performance of the
19、 power equipment at the interface A3; the input of the telecommunications equipment connected to interface A3. The voltage at interface A3 may be the ac mains, a rectified voltage derived from ac three phase mains, a rectified voltage derived from ac single phase mains or a low voltage derived from
20、a battery. The power supply equipment may incorporate a backup battery. The present document aims at providing compatibility between the power supply equipment and both the telecommunications equipment, and the different load units connected to the same interface A3 (e.g. datacom equipment). The req
21、uirements at interface A3 apply to: the output of the power supply equipment or power supply installation of telecommunications centres; the power supply input of telecommunications equipment and the datacom equipment installed at telecommunications centres; telecommunications equipment and the data
22、com equipment, installed in customers premises, whose power interface A3 is also used by equipment requiring a supply to the present document. The purpose of the present document is: to identify a power supply system with the same characteristics for all telecommunications and data communication equ
23、ipment defined in the area of application; to facilitate interworking of different (types of) loads units; to facilitate the standardization of power supply systems for telecommunications and datacom equipment; to facilitate the installation, operation and maintenance in the same network of equipmen
24、t and telecommunications and datacom systems from different origins. 2 References The following documents contain provisions which, through reference in this text, constitute provisions of the present document. References are either specific (identified by date of publication and/or edition number o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ETSIEN30013232003ENVIRONMENTALENGINEERINGEEPOWERSUPPLYINTERFACEATTHEINPUTTOTELECOMMUNICATIONSEQUIPMENTPART3OPERATEDBYRECTIFIEDCURRENTSOURCEALTERNATINGCUPDF

链接地址:http://www.mydoc123.com/p-727902.html