ETSI EN 300 132-2-2016 Environmental Engineering (EE) Power supply interface at the input to telecommunications and datacom (ICT) equipment Part 2 Operated by -48 V direct current _1.pdf
《ETSI EN 300 132-2-2016 Environmental Engineering (EE) Power supply interface at the input to telecommunications and datacom (ICT) equipment Part 2 Operated by -48 V direct current _1.pdf》由会员分享,可在线阅读,更多相关《ETSI EN 300 132-2-2016 Environmental Engineering (EE) Power supply interface at the input to telecommunications and datacom (ICT) equipment Part 2 Operated by -48 V direct current _1.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、 ETSI EN 300 132-2 V2.5.1 (2016-10) Environmental Engineering (EE); Power supply interface at the input to telecommunications and datacom (ICT) equipment; Part 2: Operated by -48 V direct current (dc) EUROPEAN STANDARD ETSI ETSI EN 300 132-2 V2.5.1 (2016-10) 2 Reference REN/EE-0252 Keywords interfac
2、e, power supply ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Important notice The present document can be dow
3、nloaded from: http:/www.etsi.org/standards-search The present document may be made available in electronic versions and/or in print. The content of any electronic and/or print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any exist
4、ing or perceived difference in contents between such versions and/or in print, the only prevailing document is the print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subj
5、ect to revision or change of status. Information on the current status of this and other ETSI documents is available at https:/portal.etsi.org/TB/ETSIDeliverableStatus.aspx If you find errors in the present document, please send your comment to one of the following services: https:/portal.etsi.org/P
6、eople/CommiteeSupportStaff.aspx Copyright Notification No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm except as authorized by written permission of ETSI. The content of the PDF version shall not be modified without th
7、e written authorization of ETSI. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2016. All rights reserved. DECTTM, PLUGTESTSTM, UMTSTMand the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members.
8、 3GPPTM and LTE are Trade Marks of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. GSM and the GSM logo are Trade Marks registered and owned by the GSM Association. ETSI ETSI EN 300 132-2 V2.5.1 (2016-10) 3 Contents Intellectual Property Rights 5g3Foreword . 5
9、g3Modal verbs terminology 5g31 Scope 6g32 References 6g32.1 Normative references . 6g32.2 Informative references 7g33 Definitions, symbols and abbreviations . 8g33.1 Definitions 8g33.2 Symbols 8g33.3 Abbreviations . 9g34 Requirements 9g34.0 Interface “A“. 9g34.1 Nominal voltage . 10g34.2 Normal serv
10、ice voltage range at interface “A“ . 10g34.3 Abnormal service voltage range at interface “A“ . 11g34.3.1 Abnormal service voltage range under steady state conditions 11g34.3.2 Abnormal conditions: voltage variations, dips and short interruptions . 11g34.3.3 Voltage transients . 11g34.3.3.1 Voltage t
11、ransient due to short-circuit and protective device clearance . 11g34.3.3.2 Short voltage transient due to switching and lightning . 12g34.3.4 Recovery from voltage transients . 12g34.4 Voltage changes due to the regulation of the power supply . 13g34.5 Power supply protection at interface “A“ . 13g
12、34.6 Maximum current drain 13g34.7 Inrush Current on connection of interface “A“ . 14g34.7.1 Limits 14g34.7.2 Measurements . 15g34.8 Conducted immunity requirements of the telecommunications equipment at interface “A“: narrowband noise . 16g34.9 Conducted emissions requirements of the telecommunicat
13、ions and datacom (ICT) equipment at interface “A“ . 18g35 Earthing and bonding . 19g3Annex A (informative): Identification of interface “A“ 20g3Annex B (informative): -60 VDCsystems 21g3Annex C (informative): Guide for measuring inrush current and for transferring the recorded pulses onto the limit
14、chart . 22g3C.1 Measurement 22g3C.2 Pulse waveform transformation 22g3C.3 Measurement of inrush current with filter capacitor current pulses . 25g3Annex D (informative): Test arrangements for the injection of electrical noise at interface “A“ 28g3Annex E (informative): Wideband noise 29g3E.0 Wideban
15、d noise 29g3E.1 Emission of wideband noise . 29g3E.1.1 Assessment of wideband noise . 29g3ETSI ETSI EN 300 132-2 V2.5.1 (2016-10) 4 E.2 How to calculate wideband emission . 29g3Annex F (informative): Protection dimensioning 33g3Annex G (informative): Effects of protective device operation transients
16、 in the power distribution . 34g3Annex H (informative): Bibliography . 35g3History 36g3ETSI ETSI EN 300 132-2 V2.5.1 (2016-10) 5 Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential
17、IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are
18、available on the ETSI Web server (https:/ipr.etsi.org/). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) whic
19、h are, or may be, or may become, essential to the present document. Foreword This European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering (EE). The present document concerns the requirements for the interface between telecommunications and datacom (ICT) equipme
20、nt and its power supply, and includes requirements relating to its stability and measurement. Various other references and detailed measurement and test arrangements are contained in informative annexes. The present document is part 2 of a multi-part deliverable covering Environmental Engineering (E
21、E); Power supply interface at the input to telecommunications and datacom (ICT) equipment, as identified below: Part 1: “Operated by alternating current (ac) derived from direct current (dc) sources“; Part 2: “Operated by -48 V direct current (dc)“; Part 3: “Operated by rectified current source, alt
22、ernating current source or direct current source up to 400 V“. National transposition dates Date of adoption of this EN: 5 October 2016 Date of latest announcement of this EN (doa): 31 January 2017 Date of latest publication of new National Standard or endorsement of this EN (dop/e): 31 July 2017 Da
23、te of withdrawal of any conflicting National Standard (dow): 31 July 2017 Modal verbs terminology In the present document “shall“, “shall not“, “should“, “should not“, “may“, “need not“, “will“, “will not“, “can“ and “cannot“ are to be interpreted as described in clause 3.2 of the ETSI Drafting Rule
24、s (Verbal forms for the expression of provisions). “must“ and “must not“ are NOT allowed in ETSI deliverables except when used in direct citation. ETSI ETSI EN 300 132-2 V2.5.1 (2016-10) 6 1 Scope The present document contains requirements and measurements methods for the physical interface that is
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ETSIEN30013222016ENVIRONMENTALENGINEERINGEEPOWERSUPPLYINTERFACEATTHEINPUTTOTELECOMMUNICATIONSANDDATACOMICTEQUIPMENTPART2OPERATEDBY48VDIRECTCURRENT_1PDF

链接地址:http://www.mydoc123.com/p-727897.html