EN ISO 9455-6-1997 en Soft Soldering Fluxes - Test Methods - Part 6 Determination and Detection of Halide (Excluding Fluoride) Content《软钎焊剂 试验方法 第6部分 卤化物(不包括氟化物)含量的检测和测定 ISO 9455-6.pdf
《EN ISO 9455-6-1997 en Soft Soldering Fluxes - Test Methods - Part 6 Determination and Detection of Halide (Excluding Fluoride) Content《软钎焊剂 试验方法 第6部分 卤化物(不包括氟化物)含量的检测和测定 ISO 9455-6.pdf》由会员分享,可在线阅读,更多相关《EN ISO 9455-6-1997 en Soft Soldering Fluxes - Test Methods - Part 6 Determination and Detection of Halide (Excluding Fluoride) Content《软钎焊剂 试验方法 第6部分 卤化物(不包括氟化物)含量的检测和测定 ISO 9455-6.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、STD-BSI BS EN IS0 9455-b-ENGL 1997 lb2VbbS b05582 bll m BRITISH STANDARD Soft soldering fluxes - Test methods Part 6. Determination and d.etection of halide (excluding fluoride) content The European Standard EN IS0 94556 : 1997 has the status of a British Standard ICs 25.160.50 BS EN IS0 9455-6 : 19
2、97 TED BY COPYRIGHT LAW - STD-BSI BS EN IS0 9455-b-ENGL 1997 1b24bbS Ob05583 558 W Amd. No. BS EN IS0 9455-6 : 1997 Date Text affected - This British Standard, having been prepared under the direction of the Engineering Sector Board, was published under the authority of the Standards Board and comes
3、 int effect on 15 April 1997 O BSI 1997 ISBN O 580 26522 6 National foreword This British Standard is the En- language version of EN IS0 94556 : 1997. It is identical with IS0 9455-6 : 1995. It partially supersedes BS 5625 : 1986 which will be withdrawn following publication of other European standa
4、rds in this series. The UK participation in its preparation was entrusted by Technid Committee NM7, lin and tin alloys, to Subcommittee NM7/4, Solders and soldering flurpes, .$ which has the responsibility to: - aid enquirers to understand the text; - present to the responsible internationaUEuropean
5、 committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; - monitor related international and European developments and promulgate them in the UK. A list of 0rg;uiizatiOns represented on this committee can be obtained on request. Cross-references At
6、tention is drawn to the fact that annex ZA lists normative references to international publications with their corresponding European publications. The British Standards which implement these international or European publications may be found in the BSI Stankc method. Method C is a titration method
7、 for the determination of the halide (excluding fluoride) content of water- soluble fluxes containing phosphates and is applica- ble to flux class 3.2.1 .A, as defined in IS0 9454-1. Method D is a qualitative test, using silver chromate test paper, for the presence of ionic halides. The technique ma
8、y be used for all classes of flux. 3 Method A: Potentiometric method (Reference method) 3.1 Principle 2 Normative references The following standards contain provisions which, through reference in this text, constitute provisions A prepared, weighed sample of the flux is dissolved in a suitable solve
9、nt. The resulting solution is titrated with standard silver nitrate solution, using a silver electrode, the mV readings being recorded simul- 1 STD.BS1 BS EN IS0 9455-b-ENGL 1997 1b29bbS Ob05590 798 BS EN IS0 9466-6 : 1997 taneously. From the graph of volume of titrant readings against mV readings,
10、the point of inflexion is determined and the percentage halide content, ex- pressed as chloride, is calculated. The method is not suitable for the determination of fluoride. This method is applicable to flux classes 1 and 2, as defined in IS0 9454-1. 3.2 Reagents 3.2.1 General Only reagents of recog
11、nized analytical quality and distilled or deionized water with a conductivity less than 10 pS/cm are to be used. 3.2.2 Propan-2-01. 3.2.3 Silver nitrate solution (0.02 mol/). 3,4 g of silver nitrate (ASNO,) are dissolved in water (see note 1) then transferred to a 1 litre volumetric flask and dilute
12、d to the mark with water. It is mixed thoroughly. Alternatively a commercially available concentrate is used to prepare 0,02 mol/ standard silver nitrate sol- ution. The silver nitrate solution is standardized using the method given in annex A, to derive the correlation factorf,. This is stored in a
13、n amber glass bottle. NOTES 1 The silver nitrate (ASNO,) should be dried at 110 “C I 5 C for 16 h and cooled in a desiccator before weighing. 2 1 ml of silver nitrate solution (3.2.3) is equivalent to 0,000 709 xfi g of chloride ion. 3.3 Apparatus Ordinary laboratory apparatus and 3.3.1 Millivott me
14、ter. 3.3.2 Silver electrode. 3.3.3 Mercury/mercurous sulfate 1 mol/l so- dium sulfate electrode, or a reversible hydrogen electrode. 3.3.4 Magnetic or mechanical stirrer, with variable speed drive, the stirrer bar to be PTFE-coated. 3.4 Procedure Carry out the following procedure, in triplicate, on
15、the flux sample. Weigh, to the nearest 0,001 g, approximately 0.5 g of the solid flux sample or 2 g of the liquid flux sam- ple, avoiding loss of volatile matter during the weigh- ing, and transfer it to a 250 ml low-form beaker. NOTE 3 This procedure is suitable for halide ion concen- trations gene
16、rally within the range 0.1 % (m/m) to 1 % (m/m) in the non-volatile content of the solution to be titrated. For flux samples having halide ion concentrations outside this range, the sample mass taken should be ad- justed, as follows: a) for flux samples having a halide ion concentration in the range
17、 0,05 K (m/m) to 0.1 % (m/m), the mass of sample taken should be double; and b) for flux samples having a halide ion concentration in the range 1 % (m/m) to 2 % (m/m), the mass of sample taken should be halved. Add 100 mi of propan-2-01 (32.2). or water, according to the solubility characteristics o
18、f the flux (see note 4). Cover with a watch glass and allow to dis- solve with gentle agitation. NOTE 4 For fluxes of class 1.2, as defined in IS0 9454-1 the choice of solvent should be agreed between the flux manufacturer and the user. Place the beaker on the stand of the titration as- sembly with
19、the electrodes, stirrer and burette in position. Adjust the speed of the stirrer to give vigor- ous stirring without splashing. Titrate with the silver nitrate solution (3.2.31, adding 1 ml portions and re- cording the mV meter readings after each addition. As the end-point is approached, reduce the
20、 additions of titrant to 0.1 ml and continue titrating past the end-point. Plot the potential values against the volume of titrant added to obtain the titration curve. The point of in- flexion of the curve corresponds to the end-point of the titration. NOTE 5 veniently be determined by using the der
21、ivative curve. The point of inflexion of the curve may con- Carry out a blank determination, using all reagents, for comparison purposes. 2 BS EN IS0 9465-6 : 1997 3.5 Calculation of results The halide (excluding fluoride) content, expressed as the percentage, by mass, of chloride in the flux, is gi
22、ven by: The test is applicable to fluxes of classes 2.1.2.A and 3.1 .I .A only, as defined in IS0 9454-1. Some liquid fluxes Contain free hydrochloric acid and the halide content will, consequently, be greater than the amount equivalent to the zinc and other chlorides present. 0,070 9 x V mft where
23、V is the volume, in millilitres, of silver nitrate solution used, less the volume needed to titrate the blank; fi is the correlation factor for the silver nitrate solution (see 3.2.3); is the mass, in grams, of the sample taken The halide content of the flux sample is given by the mean of the three
24、results obtained on the triplicate test samples. The halide content may also be expressed as the percentage, by mass, of chloride in the non-volatile matter by: 7,09 x V mS m fi where S is the percentage non-volatile matter con- tent of the sample, determined as de- scribed in IS0 94551 or IS0 9455-
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ENISO945561997ENSOFTSOLDERINGFLUXESTESTMETHODSPART6DETERMINATIONANDDETECTIONOFHALIDEEXCLUDINGFLUORIDECONTENT

链接地址:http://www.mydoc123.com/p-723804.html