EN 62471-2008 en Photobiological safety of lamps and lamp systems《灯具和灯具系统的光生物学安全[ CENELEC EN 60825-1]》.pdf
《EN 62471-2008 en Photobiological safety of lamps and lamp systems《灯具和灯具系统的光生物学安全[ CENELEC EN 60825-1]》.pdf》由会员分享,可在线阅读,更多相关《EN 62471-2008 en Photobiological safety of lamps and lamp systems《灯具和灯具系统的光生物学安全[ CENELEC EN 60825-1]》.pdf(52页珍藏版)》请在麦多课文档分享上搜索。
1、Photobiological safety of lampsand lamp systemsBS EN 62471:2008raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI British StandardsNational forewordThis British Standard is the UK implementation of EN 62471:2008. It wasderived by CENELEC from IEC 624
2、71:2006. Together with BS EN 60825-1:2007,it supersedes BS EN 60825-1:1994 which is withdrawn.The CENELEC common modifications have been implemented at the appropriate places in the text and are indicated by tags (e.g. ).The UK participation in its preparation was entrusted to Technical CommitteeEPL
3、/76, Optical radiation safety and laser equipment.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2009ISBN 9
4、78 0 580 56886 2ICS 29.140.01Compliance with a British Standard cannot confer immunity fromlegal obligations.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 62471:2008This British Standard was published under the authority of the StandardsPolicy and Strategy Commi
5、ttee on 31 March 2009 EUROPEAN STANDARD EN 62471 NORME EUROPENNE EUROPISCHE NORM September 2008 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B
6、- 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 62471:2008 E ICS 29.140 Partially supersedes EN 60825-1:1994 + A1:2002 + A2:2001 English version Photobiological safety of lamps and lamp systems (IEC 62471:2006
7、, modified) Scurit photobiologique des lampes et des appareils utilisant des lampes (CEI 62471:2006, modifie) Photobiologische Sicherheit von Lampen und Lampensystemen (IEC 62471:2006, modifiziert) This European Standard was approved by CENELEC on 2008-09-01. CENELEC members are bound to comply with
8、 the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretaria
9、t or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the of
10、ficial versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portug
11、al, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 62471:2008 - 2 -Foreword The text of the International Standard IEC 62471:2006, prepared by IEC TC 76 “Optical radiation safety and laser equipment“, together with the common modifications prepared by the Technica
12、l Committee CENELEC TC 76, Optical radiation safety and laser equipment, was submitted to the formal vote and was approved by CENELEC as EN 62471 on 2008-09-01. This European Standard partially supersedes EN 60825-1:1994 + corrigendum February 1995 + A1:2002 + A2:2001 + A2:2001/corrigendum April 200
13、4. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2009-09-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2011-09-01 Annex Z
14、A has been added by CENELEC. _ BS EN 62471:200862471 IEC:2006 3 CONTENTS FOREWORD 5 INTRODUCTION. 7 1. SCOPE.8 2. NORMATIVE REFERENCES 8 3. DEFINITIONS, SYMBOLS AND ABBREVIATIONS.8 4. EXPOSURE LIMITS 14 5. MEASUREMENT OF LAMPS AND LAMP SYSTEMS.15 5.1 Measurement conditions 5.1.1 Lamp ageing (seasoni
15、ng) .15 5.1.2 Test environment16 5.1.3 Extraneous radiation.16 5.1.4 Lamp operation.16 5.1.5 Lamp system operation 16 5.2 Measurement procedure 16 5.2.1 Irradiance measurements.165.2.2 Radiance measurements18 5.2.3 Measurement of source size 20 5.2.4 Pulse width measurement for pulsed sources20 5.3
16、Analysis methods .205.3.1 Weighting curve interpolations .205.3.2 Calculations 205.3.3 Measurement uncertainty .206. LAMP CLASSIFICATION .236.1 Continuous wave lamps.6.1.1 Exempt group .23 6.1.2 Risk Group 1 (Low-Risk) 23 6.1.3 Risk Group 2 (Moderate-Risk)24 6.1.4 Risk Group 3 (High-Risk)24 6.2 Puls
17、ed lampsBS EN 62471:2008ANNEX A (informative) SUMMARY OF BIOLOGICAL EFFECTS 26Bioeffect datasheet #1: Infrared cataract .26Bioeffect datasheet #2: Photokeratitis26Bioeffect datasheet #3: Photoretinitis.27Bioeffect datasheet #4: Retinal thermal injury28Bioeffect datasheet #5: Ultraviolet cataract29Bi
18、oeffect datasheet #6: Ultraviolet erythema30ANNEX B (informative) MEASUREMENT METHOD 32B.1 Instrumentation 32 B.1.1 Double monochromator: Recommended instrument32 B.1.2 Broadband detectors 32152324.62471 IEC:2006 4 B.2 Instrument limitations .32 B.2.1 Noise equivalent irradiance 32 B.2.2 Instrument
19、spectral response .33 B.2.3 Wavelength accuracy .34 B.2.4 Stray radiant power.34 B.2.5 Input optics for spectral irradiance measurements: Recommendation 35B.2.6 Linearity 35 B.3 Calibration sources 35 ANNEX C (informative) UNCERTAINTY ANALYSIS 36 ANNEX D (informative) GENERAL REFERENCESBS EN 62471:2
20、0084. EXPOSURE LIMITS (ELS)404.1 General 404.2 Specific factors involved in the determination and application of retinal exposure limits.404.2.1 Pupil diameter.404.2.2 Angular subtense of source and measurement field-of-view .414.3 Hazard exposure limits.424.3.1 Actinic UV hazard exposure limit for
21、the skin and eye424.3.2 Near-UV hazard exposure limit for the eye.434.3.3 Retinal blue light hazard exposure limit 444.3.4 Retinal blue light hazard exposure limit - small source.464.3.5 Retinal thermal hazard exposure limit 474.3.6 Retinal thermal hazard exposure limit weak visual stimulus .474.3.7
22、 Infrared radiation hazard exposure limits for the eye484.3.8 Thermal hazard exposure limit for the skin.4838ANNEX (informative) .ZB 40ANNEX (normative) .ZA 3962471 IEC:2006 5 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ PHOTOBIOLOGICAL SAFETY OF LAMPS AND LAMP SYSTEMS FOREWORD 1) The International E
23、lectrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote interna-tional co-operation on all questions concerning standardization in the electrical and electronic fie
24、lds. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IE
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN624712008ENPHOTOBIOLOGICALSAFETYOFLAMPSANDLAMPSYSTEMS 灯具 系统 光生物学 安全 CENELECEN608251 PDF

链接地址:http://www.mydoc123.com/p-721376.html