EN 62192-2009 en Live working - Insulating ropes《带电作业 绝缘绳索》.pdf
《EN 62192-2009 en Live working - Insulating ropes《带电作业 绝缘绳索》.pdf》由会员分享,可在线阅读,更多相关《EN 62192-2009 en Live working - Insulating ropes《带电作业 绝缘绳索》.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationLive working Insulating ropesBS EN 62192:2009National forewordThis British Standard is the UK implementation of EN 62192:2009. It is identical to IEC 62192:2009.The UK participat
2、ion in its preparation was entrusted to Technical CommitteePEL/78, Tools for live working.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for
3、 its correct application. BSI 2010ISBN 978 0 580 57283 8ICS 13.260; 29.240.20; 29.260.99Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and Strategy Committee on 31 May 2010.Amendments issu
4、ed since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 62192:2009EUROPEAN STANDARD EN 62192 NORME EUROPENNE EUROPISCHE NORM June 2009 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische
5、 Normung Central Secretariat: Avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 62192:2009 E ICS 13.260; 29.240.20; 29.260.99 English version Live working - Insulating ropes (IEC 62192:2009)
6、Travaux sous tension - Cordes isolantes (CEI 62192:2009) Arbeiten unter Spannung - Isolierende Seile (IEC 62192:2009) This European Standard was approved by CENELEC on 2009-05-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving
7、this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official vers
8、ions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of
9、 Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingd
10、om. BS EN 62192:2009EN 62192:2009 2 Foreword The text of document 78/773/FDIS, future edition 1 of IEC 62192, prepared by IEC TC 78, Live working, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 62192 on 2009-05-01. The following dates were fixed: latest date by whic
11、h the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2010-02-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2012-05-01 Annex ZA has been added by CENELEC. _ Endorsement notice The
12、text of the International Standard IEC 62192:2009 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following note has to be added for the standard indicated: IEC 60743 + A1 NOTE Harmonized as EN 60743:2001 + A1:2008 (not modified
13、). _ BS EN 62192:2009 3 EN 62192:2009 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies
14、. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60060-1 - 1)High-voltage
15、 test techniques - Part 1: General definitions and test requirements HD 588.1 S1 1991 2)IEC 60212 1971 Standard conditions for use prior to and during the testing of solid electrical insulating materials HD 437 S1 1984 IEC 60417 Data- base Graphical symbols for use on equipment - - IEC 61318 2007 Li
16、ve working - Conformity assessment applicable to tools, devices and equipment EN 61318 2008 IEC 61477 - 1)Live working - Minimum requirements for the utilization of tools, devices and equipment EN 61477 2009 2)ISO 2307 - 1)Fibre ropes - Determination of certain physical and mechanical properties EN
17、ISO 2307 2005 2)1)Undated reference. 2)Valid edition at date of issue. BS EN 62192:2009 2 62192 IEC:2009 CONTENTS INTRODUCTION.5 1 Scope.6 2 Normative references .6 3 Terms and definitions .6 4 Requirements .7 4.1 Physical and dimensional 7 4.1.1 Physical.7 4.1.2 Dimensional 7 4.2 Electrical .7 4.3
18、Mechanical7 4.4 Marking .8 4.5 Instructions for use and care .8 5 Tests 9 5.1 General .9 5.2 Atmospheric conditions .9 5.3 Visual verification and dimensional checking .9 5.3.1 Visual verification 9 5.3.2 Dimensional check 9 5.4 Electrical tests.9 5.4.1 Leakage current under dry conditions 9 5.4.2 T
19、ests after water conditioning13 5.5 Mechanical tests .14 5.5.1 Water absorption .14 5.5.2 Capillary14 5.5.3 Elongation and creep.14 5.6 Durability of marking .15 5.7 Verification of the required instructions for use15 6 Conformity assessment of insulating ropes having completed the production phase
20、.15 7 Modifications 15 Annex A (normative) Suitable for live working; double triangle (IEC 60417-5216 (2002-10).16 Annex B (normative) Chronology of type tests .17 Annex C (normative) Classification of defects 18 Annex D (informative) Recommendations for in-service care and periodic testing 19 Bibli
21、ography21 Figure 1 Example of test set up to measure leakage current 10 Figure 2 Electrode arrangement on rope test piece 12 Table B.1 Chronology of type tests 17 Table C.1 Classification of defects and associated requirements and tests 18 BS EN 62192:200962192 IEC:2009 5 INTRODUCTION Insulating rop
22、es designed and manufactured according to this standard contribute to the safety of the users, provided they are used by skilled persons, in accordance with safe methods of work and the instructions for use. This International Standard defines the required electrical properties of insulating ropes w
23、hich already meet other specifications relating to mechanical strength, physical and construction properties, for use in live working at the power frequency system voltages up to and including 800 kV r.m.s. This standard does not propose to address all the safety factors associated with the use of t
24、he insulating rope. It is the responsibility of the user to establish appropriate safety practices. Ropes which meet this standard can bridge two or more live phase conductors, or one phase conductor and earth as required during live working. Effects of the use of insulating ropes on the dielectric
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN621922009ENLIVEWORKINGINSULATINGROPES 带电作业 绝缘 绳索 PDF

链接地址:http://www.mydoc123.com/p-721041.html