EN 61391-1-2006 en Ultrasonics - Pulse-echo scanners Part 1 Techniques for calibrating spatial measurement systems and measurement of system point-spread function response (Incorpo.pdf
《EN 61391-1-2006 en Ultrasonics - Pulse-echo scanners Part 1 Techniques for calibrating spatial measurement systems and measurement of system point-spread function response (Incorpo.pdf》由会员分享,可在线阅读,更多相关《EN 61391-1-2006 en Ultrasonics - Pulse-echo scanners Part 1 Techniques for calibrating spatial measurement systems and measurement of system point-spread function response (Incorpo.pdf(50页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 61391-1:2006Ultrasonics Pulse-echo scanners Part 1: Techniques for calibrating spatial measurement systems and measurement of system point-spread function responseThe European Standard EN 61391-1:2006 has the status of a British StandardICS 17.140.50g49g50g3g38g50g51g60g44g49g4
2、2g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 61391-1:2006This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 J
3、anuary 2007 BSI 2007ISBN 978-0-580-49923-4National forewordThis British Standard was published by BSI. It is the UK implementation of EN 61391-1:2006. It is identical with IEC 61391-1:2006.The UK participation in its preparation was entrusted to Technical Committee EPL/87, Ultrasonics.A list of orga
4、nizations represented on EPL/87 can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amen
5、dments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARD EN 61391-1 NORME EUROPENNE EUROPISCHE NORM October 2006 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secr
6、etariat: rue de Stassart 35, B - 1050 Brussels 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61391-1:2006 E ICS 17.140.50 English version Ultrasonics - Pulse-echo scanners Part 1: Techniques for calibrating spatial measurem
7、ent systems and measurement of system point-spread function response (IEC 61391-1:2006) Ultrasons - Scanners impulsion et cho Partie 1: Techniques pour ltalonnage des systmes de mesure spatiaux et des mesures de la rponse de la fonction de dispersion ponctuelle du systme (CEI 61391-1:2006) Ultrascha
8、ll - Impuls-Echo-Scanner Teil 1: Verfahren fr die Kalibrierung von rumlichen Messsystemen und Messung der Charakteristik der Punktverwaschungsfunktion des Systems (IEC 61391-1:2006) This European Standard was approved by CENELEC on 2006-10-01. CENELEC members are bound to comply with the CEN/CENELEC
9、 Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENE
10、LEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.
11、 CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slo
12、venia, Spain, Sweden, Switzerland and the United Kingdom. Foreword The text of document 87/336/FDIS, future edition 1 of IEC 61391-1, prepared by IEC TC 87, Ultrasonics, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61391-1 on 2006-10-01. The following dates were f
13、ixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2007-07-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2009-10-01 Terms in bold in the text are define
14、d in Clause 3. Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61391-1:2006 was approved by CENELEC as a European Standard without any modification. _ 2 EN 61391-1:2006CONTENTS INTRODUCTION.4 1 Scope.5 2 Normative references5 3 Terms and definition
15、s .5 4 Symbols .11 5 General conditions11 6 Techniques for calibrating 2D-measurement systems13 6.1 Test methods 13 6.2 Instruments .13 6.3 Test settings14 6.4 Test parameters 15 7 Methods for calibrating 3D-measurement systems.17 7.1 General .17 7.2 Types of 3D-reconstruction methods18 7.3 Test par
16、ameters associated with reconstruction problems19 7.4 Test methods for measurement of 3D-reconstruction accuracy.20 8 Measurement of point-spread and line-spread functions (high-contrast spot size) 24 8.1 General .24 8.2 Test methods 25 8.3 Instruments .25 8.4 Test settings25 8.5 Test parameters 28
17、Annex A (normative) Test objects Calibration of 2D-spatial measurement systems.33 Annex B (normative) Test objects Measurement and calibration of 3D-image reconstruction accuracy 36 Annex C (normative) Test objects Measurement of point-spread function response39 Bibliography44 3 EN 61391-1:2006Annex
18、 ZA (normative) Normative references to international publications with their corresponding European publications.46 INTRODUCTION An ultrasonic pulse-echo scanner produces images of tissue in an ultrasonic scan plane by sweeping a narrow pulsed beam of ultrasound through the section of interest and
19、detecting the echoes generated at tissue boundaries. A variety of ultrasonic transducer types are employed to operate in a transmit/receive mode for the ultrasonic signals. Ultrasonic scanners are widely used in medical practice to produce images of many soft-tissue organs throughout the human body.
20、 This standard describes test procedures that should be widely acceptable and valid for a wide range of types of equipment. Manufacturers should use the standard to prepare their specifications; the users should employ the standard to check specifications. The measurements can be carried out without
21、 interfering with the normal working conditions of the machine. Typical test objects are described in the annexes. The structures of the test objects have not been specified in detail, rather suitable types of overall and internal structures are described. The specific structure of a test object sho
22、uld be reported with the results obtained using it. Similar commercial versions of these test objects are available. The performance parameters specified and the corresponding methods of measurement have been chosen to provide a basis for comparison with the manufacturers specification and between s
23、imilar types of apparatus of different makes, intended for the same kind of diagnostic application. The manufacturers specification should allow comparison with the results obtained from the tests in this standard. Furthermore, it is intended that the sets of results and values obtained from the use
24、 of the recommended methods will provide useful criteria for predicting the performance of equipment in appropriate diagnostic applications. This standard concentrates on measurements of images by digital techniques. Methods suitable for inspection by eye are covered here as well. Discussion of othe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN6139112006ENULTRASONICSPULSEECHOSCANNERSPART1TECHNIQUESFORCALIBRATINGSPATIALMEASUREMENTSYSTEMSANDMEASUREMENTOFSYSTEMPOINTSPREADFUNCTIONRESPONSEINCORPOPDF

链接地址:http://www.mydoc123.com/p-720182.html