EN 61329-1996 en Sound System Equipment Methods of Measuring and Specifying the Performance of Sounders (Electroacoustic Transducers for Tone Production)《音响系统设备 测量和规范发声器性能的方法(发声用电解.pdf
《EN 61329-1996 en Sound System Equipment Methods of Measuring and Specifying the Performance of Sounders (Electroacoustic Transducers for Tone Production)《音响系统设备 测量和规范发声器性能的方法(发声用电解.pdf》由会员分享,可在线阅读,更多相关《EN 61329-1996 en Sound System Equipment Methods of Measuring and Specifying the Performance of Sounders (Electroacoustic Transducers for Tone Production)《音响系统设备 测量和规范发声器性能的方法(发声用电解.pdf(25页珍藏版)》请在麦多课文档分享上搜索。
1、CENELEC EN*bL*329 96 3404583 OL7LO4 BT9 BRITISH STANDARD Sound system equipment - Methods of measuring and specifying the performance of sounders (electroacoustic transducers for tone production) The European Standard EN 61329 : 1996 has the status of a British Standard ICs 33.160.30 NO COPYING WITH
2、OUT BSI PERMISSION EXCEPT AS PERMITED BY COPYJtIGHT LAW BS EN 61329 : 1996 IEC 1329 : 1995 CENELEC EN*b1*329 96 = 3404583 0177105 735 BS EN 61329 : 1996 This British Standard, having been prepared under the direction of the Eleclx In figures 4 and 5 (see 5.6.1) has been replaced by (see 5.5.1). Comp
3、liance with a British Standard does not of itself confer immunity from legal obligations. ii O BSI 1996 CENELEC EN*bl*329 b m 3404583 0177108 444 EUROPEAN STANDARD EN 61329 NORME EUROPENNE EUROP piezoelectric ceramic disc: Thin plate made of a piezoelectric ceramic, for example lead zirconate titana
4、te (PT) ceramic, of which each side is metallized. The ceramic plate is polarized so as to deform radially when a voltage is applied across it. 3.2 Characteristics, symbols and units 3.2.1 sounder or a piezoelectric diaphragm. Symbol: Urms, unit: V. input voltage (sinusoidal signal): RMS voltage of
5、a sinusoidal signal applied to a 3.2.2 applied to a sounder. Symbol: Upp, unit: V. input voltage (square wave signal): Peak-to-peak voltage of a square-wave signal NOTE - The sounder or piezoelectric diaphragm may require, or tolerate, a d.c. component in addition to the square wave, in which case t
6、he required or tolerated signal waveform will be specified, as illustrated in figure 1. 3.2.3 d.c. polarity (of an electromagnetic or an electrodynamic sounder): Direction of the d.c. component applied to an electromagnetic or electrodynamic sounder which is designed to be driven by a positively-bia
7、sed or negatively-biased square-wave input voltage. CENELEC EN*bl*32 b = 3404583 OL77LL2 975 = Page 6 EN 61329 : 1996 3.2.4 voltage, applied for polarization of the piezoelectric ceramic during production. direction of polarization (of a piezoelectric ceramic plate): Direction of the d.c. 3.2.5 reso
8、nant frequency (of a sounder): Frequency within the rated frequency range, at which the output sound pressure of a sounder shows a local maximum. Symbol: fr, unit: Hz. 3.2.6 resonant frequency (of a piezoelectric diaphragm): Frequency close to the eigenfrequency of the first symmetrical vibration mo
9、de for the free boundary condition, at which the electrical impedance of the piezoelectric diaphragm shows a local minimum. Symbol: fr, unit: Hz. 3.2.7 anti-resonant frequency (of a piezoelectric diaphragm): Frequency close to the eigenfrequency of the first symmetrical vibration mode for the free b
10、oundary condition, at which the electrical impedance of a piezoelectric diaphragm shows a local maximum. Symbol: fa, unit: Hz. 3.2.8 sensitivity level to voltage (with A-weighting): Output sound pressure level of a sounder measured using a sound level meter with A-weighting, referred to an input vol
11、tage of 1 V and to a distance of 1 m. The measuring frequency and input signal waveform are as specified by the manufacturer. Symbol: SA, unit: dB ref. 20 pPa. NOTE - The A-weighting characteristic is specified in IEC 651. 3.2.9 distance to measuring point: Distance between the reference point of a
12、sounder to be measured and the reference point of the microphone used for the measurements, specified as one of the measuring conditions. Symbol: r, unit: m. 3.2.1 O principal axis (of microphone): Line through the geometrical centre, and perpendicular to the reference plane, of the microphone used
13、for measurement. NOTE - The front surface of the microphone should be taken as the reference plane, if the reference plane of the microphone is not specified by the manufacturer. 3.2.11 reference point (of microphone): Point where the principal axis of the microphone intersects the reference plane.
14、For additional information, see note to 3.2.10. 4 Rated conditions For a full explanation of the terms rated value and rated condition, see IEC 268-2. The following conditions shall be specified by the manufacturer of the sounder. 4.1 Rated input voltage The continuous input voltage at which the sou
15、nder operates normally for the specified period of time. The frequency and waveform of the input signal shall be specified. Symbol: Ur, unit: V. CENELEC EN*bL*329 96 = 3404583 OL77LL3 801 M Page 6 EN 61329 : 1996 4.2 Rated maximum input voltage The maximum voltage which can be applied to the sounder
16、 for a specified short time. The frequency and waveform of the input signal shall be specified. Symbol: Um, unit: V. 4.3 Rated frequency range The frequency range for continuous sinusoidal input signal over which the sounder can operate normally. The input voltage shall be specified. 4.4 Rated resis
17、tance The d.c. resistance of an electromagnetic or electrodynamic sounder specified for matching purposes. Symbol: Rr, unit: i2 4:5 Rated capacitance The electrical capacitance of the piezoelectric sounder specified for matching purposes. Symbol: Cr , unit: nF. 4.6 Principal axis (of sounder) The li
18、ne through the geometrical centre of the sound hole(s), perpendicular to the front surface of the sounder. For additional information, see note to 4.7. 4.7 Reference point (of sounder) The point where the principal axis of the sounder intersects the front surface. NOTE - Strictly. this term and that
19、 defined in the previous subclause should include the word rated (for example. rated reference point), since they are specified by the manufacturer in accordance with these definitions and cannot be measured, but confusion is unlikely even if the shorter terms are used. 4.8 Rated working temperature
20、 range The environmental temperature range over which a sounder can operate normally. 5 Characteristics and measuring methods 5.1 Measuring conditions 5.1 .l Environmental noise and other interferences The disturbance of measured sound pressure level due to environmental or other noises shall not ex
21、ceed 1 dB. 5.1.2 Climatic and environmental conditions Unless otherwise specified by the manufacturer, measurements shall be made under the following environmental conditions: 15 OC to 35 “C, preferably at 20 OC; - ambient temperature: CENELEC EN*bL*32 b = 3404583 0177114 746 Page 7 EN 61329 : 1996
22、- relative humidity: 25 Yo to 75 Yo - air pressure: 86 kPa to 106 kPa. NOTE - For further information, see IEC 268-1, IEC 68 and IEC guide 106. 5.1.3 Acoustic environment for measurement In the frequency range 500 Hz to 10 kHz, the variation, due to acoustic reflections or reverberation, of sound pr
23、essure level with distance shall not deviate by more than 1 dB from the response in an ideal free sound field, in the range of distance from 0,l m to that of the measuring point. 5.1.4 Measuring signal waveform The waveform of the signal for measurement shall be sinusoidal or square. The signal volt
24、age shall be stated as the r.rn.s. value for a sinusoidal signal and as the peak-to-peak value for a square wave signal. For a square-wave signal, information on any necessary d.c. component shall be given (see figure 1). 5.2 Measuring equipment 5.2.1 Sound level meter A sound level meter conforming
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN613291996ENSOUNDSYSTEMEQUIPMENTMETHODSOFMEASURINGANDSPECIFYINGTHEPERFORMANCEOFSOUNDERSELECTROACOUSTICTRANSDUCERSFORTONEPRODUCTION

链接地址:http://www.mydoc123.com/p-720095.html