EN 61019-2-2005 en Surface acoustic wave (SAW) resonators Part 2 Guide to the use《表面声波(SAW)谐振器 第2部分 使用指南》.pdf
《EN 61019-2-2005 en Surface acoustic wave (SAW) resonators Part 2 Guide to the use《表面声波(SAW)谐振器 第2部分 使用指南》.pdf》由会员分享,可在线阅读,更多相关《EN 61019-2-2005 en Surface acoustic wave (SAW) resonators Part 2 Guide to the use《表面声波(SAW)谐振器 第2部分 使用指南》.pdf(30页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 61019-2:2005Surface acoustic wave (SAW) resonators Part 2: Guide to the useThe European Standard EN 61019-2:2005 has the status of a British StandardICS 31.140g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g3
2、6g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 61019-2:2005This British Standard was published under the authority of the Standards Policy and Strategy Committee on 17 October 2005 BSI 17 October 2005ISBN 0 580 46399 0National forewordThis British Standard is
3、the official English language version of EN 61019-2:2005. It is identical with IEC 61019-2:2005. It supersedes BS EN 61019-2:1997 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee EPL/49, Piezo-electric devices for frequency control and selection, which
4、has the responsibility to:A list of organizations represented on this committee can be obtained on request to its secretary.Cross-referencesThe British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section en
5、titled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Complianc
6、e with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor related interna
7、tional and European developments and promulgate them in the UK.Summary of pagesThis document comprises a front cover, an inside front cover, the EN title page, pages 2 to 26, an inside back cover and a back cover.The BSI copyright notice displayed in this document indicates when the document was las
8、t issued.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARD EN 61019-2 NORME EUROPENNE EUROPISCHE NORM June 2005 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Ce
9、ntral Secretariat: rue de Stassart 35, B - 1050 Brussels 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61019-2:2005 E ICS 31.140 Supersedes EN 61019-2:1997English version Surface acoustic wave (SAW) resonators Part 2: Guide
10、 to the use (IEC 61019-2:2005) Rsonateurs ondes acoustiques de surface (OAS) Partie 2: Guide demploi (CEI 61019-2:2005) Oberflchenwellenresonatoren (OFW-Resonatoren) Teil 2: Leitfaden fr die Anwendung (IEC 61019-2:2005) This European Standard was approved by CENELEC on 2005-06-01. CENELEC members ar
11、e bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to
12、the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the
13、 same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Po
14、rtugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Foreword The text of document 49/714/FDIS, future edition 2 of IEC 61019-2, prepared by IEC TC 49, Piezoelectric and dielectric devices for frequency control and selection, was submitted to the IEC-CENELEC parallel vote and w
15、as approved by CENELEC as EN 61019-2 on 2005-06-01. This European Standard supersedes EN 61019-2:1997. The main changes with respect to EN 61019-2:1997 are listed below: at the end of 5.1, the edge reflector has been added. Its reference literature has been inserted in the bibliography; in Table 1,
16、the propagation properties of LiNbO3 (64 Y) have been added; in Table 3, the clause and subclause numbers have been corrected in order to be consistent with EN 61019-1:2005. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an ident
17、ical national standard or by endorsement (dop) 2006-03-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2008-06-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61019-2:2005 was approved by CENELEC
18、 as a European Standard without any modification. _ 2 EN 61019-2:2005 3 CONTENTS INTRODUCTION.4 1 Scope.5 2 Normative references .5 3 Technical considerations 5 4 Fundamentals of SAW resonators.6 4.1 Basic structure 6 4.2 Principle of operation 6 5 SAW resonator characteristics7 5.1 Reflector charac
19、teristics7 5.2 SAW resonator characteristics.9 5.3 Spurious modes 13 5.4 Substrate materials and their characteristics .14 5.5 Available characteristics16 6 Application guide18 6.1 Oscillator circuits and oscillation condition 18 6.2 Practical remarks for oscillator applications.20 7 Checklist of SA
20、W resonator parameters for drawing up specifications 21 Bibliography24Annex ZA (normative) Normative references to international publications with their corresponding European publications .26EN 61019-2:2005 4 INTRODUCTION This part of IEC 61019 gives practical guidance to the use of SAW resonators
21、which are used in telecommunications, radio equipments and consumer products. IEC 61019-1 can be referred to for general information, standard values and test conditions. The features of these SAW resonators are small size, light weight, adjustment-free and high stability. In addition, the operating
22、 frequency of SAW resonators extends to the VHF and UHF ranges. This part has been compiled in response to a generally expressed desire on the part of both users and manufacturers for a guide to the use of SAW resonators, so that the resonators may be used to their best advantage. To this end, gener
23、al and fundamental characteristics have been explained in this guide. EN 61019-2:2005 5 SURFACE ACOUSTIC WAVE (SAW) RESONATORS Part 2: Guide to the use 1 Scope SAW resonators are now widely used in a variety of applications: VCR RF-converters, CATV local oscillators, measuring equipment, remote cont
24、rol and so on. While SAW resonators are also applied to narrow bandwidth filters, the scope of this part of IEC 61019 is limited to SAW resonators for oscillator applications It is not the aim of this guide to explain theory, nor to attempt to cover all the eventualities which may arise in practical
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN6101922005ENSURFACEACOUSTICWAVESAWRESONATORSPART2GUIDETOTHEUSE 表面 声波 SAW 谐振器 部分 使用指南 PDF

链接地址:http://www.mydoc123.com/p-719352.html