EN 60964-2010 en Nuclear power plants - Control rooms - Design《核电站 控制室 设计》.pdf
《EN 60964-2010 en Nuclear power plants - Control rooms - Design《核电站 控制室 设计》.pdf》由会员分享,可在线阅读,更多相关《EN 60964-2010 en Nuclear power plants - Control rooms - Design《核电站 控制室 设计》.pdf(44页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationNuclear Power Plants Control rooms DesignBS E 60964:20 0N 1National forewordThis British Standard is the UK implementation of EN 60964:2010. It is identicalThe UK participation i
2、n its preparation was entrusted to Technical CommitteeNCE/8, Reactor instrumentation.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its
3、correct application. BSI 2010ISBN 978 0 580 68112 7ICS 27.120.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and Strategy Committee on 30 June 2009Amendments issued since publicationDate
4、 Text affectedBRITISH STANDARDBS EN 60964:2010to IEC 60964:2009. It supersedes BS IEC 60964:2009 which is withdrawn./corrigenda30 June 2010 This corrigendum renumbers BS IEC 60964:2009 asBS EN 60964:2010.EUROPEAN STANDARD EN 60964 NORME EUROPENNE EUROPISCHE NORM March 2010 CENELEC European Committee
5、 for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: Avenue Marnix 17, B - 1000 Brussels 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC member
6、s. Ref. No. EN 60964:2010 E ICS 27.120.20 English version Nuclear power plants - Control rooms - Design (IEC 60964:2009) Centrales nuclaires de puissance - Salles de commande - Conception (CEI 60964:2009) Kernkraftwerke - Warten - Auslegung (IEC 60964:2009) This European Standard was approved by CEN
7、ELEC on 2010-03-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standa
8、rds may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notif
9、ied to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
10、Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Foreword The text of the International Standard IEC 60964:2009, prepared by SC 45A, Instrumentation and control of nuclear facilities, of IEC TC 45
11、, Nuclear instrumentation, was submitted to the CENELEC formal vote for acceptance as a European Standard and was approved by CENELEC as EN 60964 on 2010-03-01. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall
12、 not be held responsible for identifying any or all such patent rights. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2011-03-01 latest date by which the national standards
13、conflicting with the EN have to be withdrawn (dow) 2013-03-01 Annex ZA has been added by CENELEC. As stated in the nuclear safety Directive 2009/71/EURATOM, Chapter 1, Article 2, Item 2, Member States are not prevented from taking more stringent safety measures in the subject-matter covered by the D
14、irective, in compliance with Community law. In a similar manner, this European Standard does not prevent Member States from taking more stringent nuclear safety measures in the subject-matter covered by this European Standard.” _ Endorsement notice The text of the International Standard IEC 60964:20
15、09 was approved by CENELEC as a European Standard without any modification. _ BS EN 60964:2010EN 60964:2010 (E) 2 CONTENTS INTRODUCTION. 1 Scope and object 2 Normative references . 3 Terms and definitions . 4 Standard use11 5 Design principles for the main control room 15 5.1 Main objectives of the
16、main control room.15 5.2 Functional design objectives of the main control room.15 5.3 Safety principles15 5.4 Availability principles.15 5.5 Human factors engineering principles16 5.6 Utility operating principles .16 5.7 Relationship with other control and management centres 16 5.8 Operational exper
17、ience .17 6 Functional design of the main control room 17 6.1 General .17 6.2 Functional analysis17 6.2.1 General .17 6.2.2 Identification of functions.17 6.2.3 Information flow and processing requirements .17 6.3 Assignment of functions 18 6.3.1 General .18 6.3.2 Operator capabilities .18 6.3.3 I P
18、lanned - Deviations in process conditions or equipment status that are the expected response to but could be indicative of undesirable plant conditions. IEC 62241 3.2 auxiliary control (operating) systems operating systems that are installed outside the control room such as local-to-plant control po
19、ints and local-to-plant shutdown systems 3.3 control room staff a group of plant personnel stationed in the control room, who are responsible for achieving the plant operational goals by controlling the plant through the human-machine interface. BS EN 60964:2010EN 60964:2010 (E) 8 Typically, the con
20、trol room staff consists of supervisory operators, and operators who actually manipulate controls but may also include those staff members and experts who are authorized to be present in the control room, e.g. during long lasting event sequences 3.4 control room system an integration of the human-ma
21、chine interface, the control room staff, operating procedures, training programme, and associated facilities or equipment which together sustain the proper functioning of the control room 3.5 controls devices which the operator uses to send demand signals to control systems and plant items NOTE Cont
22、rols as defined in this standard (i.e. devices used for control actions) hold a different meaning from the one defined in the IAEA safety Glossary and are not replaceable. 3.6 displays devices used for monitoring plant conditions and status, e.g. process status, equipment status 3.7 format (display
23、format) a pictorial display of information on a visual display unit (VDU) such as message text, digital presentation, symbols, mimics, bar-charts, trend graphs, pointers, multi-angular presentation 3.8 function specific purpose or objective to be accomplished, that can be specified or described with
24、out reference to the physical means of achieving it IEC 61226 3.9 functional analysis the examination of the functional goals of a system with respect to available manpower, technology, and other resources, to provide the basis for determining how the function may be assigned and executed 3.10 funct
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN609642010ENNUCLEARPOWERPLANTSCONTROLROOMSDESIGN 核电站 控制室 设计 PDF

链接地址:http://www.mydoc123.com/p-719209.html