EN 60761-5-2004 en Equipment for continuous monitoring radioactivity in gaseous effluents Part 5 Specific requirements for tritium monitors《气态排出物放射性连续监控设备 第5部分 氚监测器的特殊要求 IEC 60761-.pdf
《EN 60761-5-2004 en Equipment for continuous monitoring radioactivity in gaseous effluents Part 5 Specific requirements for tritium monitors《气态排出物放射性连续监控设备 第5部分 氚监测器的特殊要求 IEC 60761-.pdf》由会员分享,可在线阅读,更多相关《EN 60761-5-2004 en Equipment for continuous monitoring radioactivity in gaseous effluents Part 5 Specific requirements for tritium monitors《气态排出物放射性连续监控设备 第5部分 氚监测器的特殊要求 IEC 60761-.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 60761-5:2004 Incorporating Amendment No. 1 to BS IEC 60761-5:2002 (renumbers the BS IEC as BS EN 60761-5:2004) Equipment for continuous monitoring radioactivity in gaseous effluents Part 5: Specific requirements for tritium monitors The European Standard EN 60761-5:2004 has th
2、e status of a British Standard ICS 13.280 BS EN 60761-5:2004 This British Standard, having been prepared under the direction of the Engineering Sector Policy and Strategy Committee, was published under the authority of the Standards Policy and Strategy Committee on 4 December 2002 BSI 10 March 2005
3、ISBN 0 580 40882 5 National foreword This British Standard is the official English language version of EN 60761-5:2004. The CENELEC common modifications have been implemented at the appropriate places in the text. The start and finish of each common modification is indicated in the text by tags . Wh
4、ere a common modification has been introduced by amendment, the tags carry the number of the amendment. For example, the common modifications introduced by CENELEC amendment A11 are indicated by . The UK participation in its preparation was entrusted to Technical Committee NCE/2, Health physics inst
5、rumentation, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogu
6、e under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correc
7、t application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests infor
8、med; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 16, the Annex ZA page and a back cover. The BSI copyright notice displayed in this document indicat
9、es when the document was last issued. Amendments issued since publication Amd. No. Date Comments 15423 10 March 2005 Implementation of the European StandardEUROPEAN STANDARD EN 60761-5 NORME EUROPENNE EUROPISCHE NORM December 2004 CENELEC European Committee for Electrotechnical Standardization Comit
10、 Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2004 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60761-5:2004 E ICS 13.280
11、English version Equipment for continuous monitoring radioactivity in gaseous effluents Part 5: Specific requirements for tritium monitors (IEC 60761-5:2002, modified) Equipements de surveillance en continu de la radioactivit dans les effluents gazeux Partie 5: Exigences particulires aux moniteurs de
12、 tritium (CEI 60761-5:2002, modifie) Einrichtungen zur kontinuierlichen berwachung von Radioaktivitt in gasfrmigen Ableitungen Teil 5: Besondere Anforderungen an Tritiummonitore (IEC 60761-5:2002, modifiziert) This European Standard was approved by CENELEC on 2004-11-01. CENELEC members are bound to
13、 comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Centra
14、l Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same stat
15、us as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Sl
16、ovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. NE 067-165:2004 2 Foreword The text of the International Standard IEC 60761-5:2002, prepared by SC 45B, Radiation protection instrumentation, of IEC TC 45, Nuclear instrumentation, together with the common modifications prepared by the
17、 CENELEC BTTF 111-3 Instrumentation for ionizing radiation measurement and protection, was submitted to the formal vote and was approved by CENELEC as EN 60761-5 on 2004-11-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an id
18、entical national standard or by endorsement (dop) 2005-11-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2007-11-01 Annex ZA has been added by CENELEC. _ Page2 EN607615:2004-167062002:CEI 5 5 EQUIPMENT FOR CONTINUOUS MONITORING OF RADIOACTIVITY IN G
19、ASEOUS EFFLUENTS Part 5: Specific requirements for tritium monitors 1 Scope and object This part of IEC 60761 is applicable to equipment intended for the simultaneous, delayed or discrete sequential measurement of tritium in any gaseous form in gaseous effluents dis- charged into the environment. It
20、 is applicable to equipment designed to fulfill the following functions: the measurement of the concentration of tritium in the gaseous effluents at the discharge point and its variation with time; the actuation of an alarm when a predetermined volumic activity or a predetermined total released radi
21、oactivity is exceeded. The equipment may also be used for the determination of the tritium activity discharge over a given period. The object of this standard is to establish specific standard requirements, including technical characteristics and general test conditions and to give examples of accep
22、table methods for the tritium effluent monitors defined in clause 4. The general requirements, technical characteristics, test procedures, radiation characteristics, electrical, mechanical, safety and environmental characteristics are given in IEC 60761-1. Unless otherwise stated, these requirements
23、 apply in this standard. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of IEC 60761. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. Howeve
24、r, parties to agreements based on this part of IEC 60761 are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies. Members of IEC and ISO mai
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN6076152004ENEQUIPMENTFORCONTINUOUSMONITORINGRADIOACTIVITYINGASEOUSEFFLUENTSPART5SPECIFICREQUIREMENTSFORTRITIUMMONITORS

链接地址:http://www.mydoc123.com/p-718849.html