EN 60645-2-1997 en Audiometers Part 2 Equipment for Speech Audiometry《听力计 第2部分 语言测听装置 IEC 645-2-1993》.pdf
《EN 60645-2-1997 en Audiometers Part 2 Equipment for Speech Audiometry《听力计 第2部分 语言测听装置 IEC 645-2-1993》.pdf》由会员分享,可在线阅读,更多相关《EN 60645-2-1997 en Audiometers Part 2 Equipment for Speech Audiometry《听力计 第2部分 语言测听装置 IEC 645-2-1993》.pdf(23页珍藏版)》请在麦多课文档分享上搜索。
1、STD*BSI BS EN bOb45-2-ENGL 1797 = Lb24bb7 Ob38bb5 79T M BRITISH STANDARD Audiometers Part 2. Equipment for speech audiometry The European Standard EN 606452 : 1997 has the status of a British Standard ICs 17.140.50 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BS EN 50645-2
2、: 1997 EC 60645-2 : 1993 BS EN 60645-2 : 1997 Amd.No. National foreword Date Text affected This British Standard is the English language version of EN 606452 : 1997. It is identical with IEC 60645-2 : 1993. The UK participation in its preparation was entrusted to Technical Committee EPM9, Electroaco
3、ustics, which has the responsibility to: - aid enquirers to understand the text, - present to the responsible internationalEuropean committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; - monitor related international and European developments an
4、d promulgate them in the UK A iist of organizations represented on this committee can be obtained on request to its secretary. From 1 January 1997, all lEC publications have the number 60000 added to the old number. For instance, IEC 27-1 has been renumbered as LEX 60027-1. For a period of time duri
5、ng the change over from one numbering system to the other, publications may contain identifiers from both systems. Cross-references Attention is drawn to the fact that CEN and CENELEC Standards normally include an annex which lists normative references to international publications with their corres
6、ponding European publications. The British Standards which implement these international or European publications may be found in the BSI Standards Catalogue under the section entitled International Standards Correspondence Index, or using the Find facility of the BSI Standards Electronic Catalogue.
7、 Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 20, an inside back cover and a back cover. This British Standard, having been prepared under the
8、 direction of the Electrotechnicai Sector Board, was published under the authority of the Standards Board and comes into effect on 15 September 1997 O BSI 1997 ISBN O 580 27794 1 EUROPEAN STANDARD NORME EUROPEENNE EUROPISCHE NORM EN 60645-2 January 1997 ICs 17.140.60 Descriptors: Acoustics, audiomet
9、ry, audiometers, measurements, auditory perception, clwsification, testing con 1997 CONTENTS INTRODUCTION clause 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Scope and object . Normative references Definitions . General requirements . Minimum requirements for specific types of audiometers Reference con
10、ditions for specification . testing and calibration of speech audiometers Signal level indicator . Output levei control for speech signals . Output sound-pressure level and vibratory force level . Frequency response Harmonic distortion . Signal-to-noise ratio Masking sound . Monitor earphone or loud
11、speaker Talkback system Interrupter switches . Marking and instruction manual . 4 5 5 6 8 0 8 10 10 10 11 12 13 13 14 14 14 14 Annex A . Correction figures for free-field equivalent output for certain types of commonly used earphones . 16 Annex ZA (normative) Normative references to international pu
12、blications with their corresponding European publications . 20 O BSI 1997 - STD.BSI BS EN bOb45-2-ENGL 1997 Lb2qbbS Ob38b70 257 = Page 4 EN 60645-2 : 1997 INTRODUCTION Part 1 of IEC 645 details the requirements for pure-tone audiometers in terms of per- formance characteristics of component modules.
13、 Some of these modules are common to speech audiometers for example the output level control, transducers, etc. This part 2 of IEC 645 specifies the requirements for speech audiometers- However, to avoid duplication, it only makes reference to pari I of IEC 645-1 where common elements are concerned
14、. Performance requirements are given for both live voice and recorded speech inputs. Although live voice speech audiometry may not be capable of meeting the object of this standard. it is widely practised, particularly with children, and therefore a specification is included in order to ensure as hi
15、gh a degree of reliability as possible. This standard does not specify the speech material that is used for test purposes or the required acoustic properties of the test room. Speech audiometers use earphones, bone vibrators or loudspeakers to present signals to the test subject. In order to relate
16、earphone or bone vibrator listening to sound field listening, the concept of a free-field equivalent output level of an earphone or a bone vibrator as described in IEC 268-7 is used for specification and measurement purposes. The free-field equivalent output method is fundamental in relating earphon
17、e or bone vibrator output level to sound-field measurements and for the comparison of different types of transducers. For audiometric purposes where only earphone measurements with one specific type are made, a requirement may not exist to maintain the free-fieid ear- phone relationship. Therefore,
18、in this standard, specifications of the performance charac- teristics of speech audiometers and relevant calibration and test methods are given with respect to both a free-field equivalent output level method and an uncorrected coupler out- put level method. * * 10 Page 5 EN 60645-2 : 1997 AU DIOMET
19、ERS Part 2: Equipment for speech audiometry 1 Scope and object This part of IEC 645 specifies requirements for audiometers or parts thereof designed to provide a means of presenting speech sounds to a subject in a standardized manner, for example for the measurement of speech recognition. Audiometer
20、s are classified into four types: type A instruments provide a wide range of facilities, while type i3 provides only basic facilities. For both types, the audiometer may be calibrated in terms of a free-field equivalent output level of the earphones and then be des- ignated as type A-E or B-E. This
21、standard excludes the requirements for speech audiometers provided with frequency response adjustments intended to determine an optimal intelligibility frequency response curve for each subject. The purpose of this standard is to ensure that tests of hearing using speech as the test stimulus, on a g
22、iven human ear performed with different audiometers which comply with this standard, shall give substantially the same resulis for a given caiibration method. Two methods of specification, calibration and testing are given for the output levels generated by the earphones and the bone vibrator: a) a
23、free-field equivalent output level method with audiometers of types A-E and B-E; b) an uncorrected coupler output level method with audiometers of types A and B. NOTE - The results will also depend on factors other than the audiometer for example test materid, test room, speakers, etc. 2 Normative r
24、eferences The following normative documents contain provisions which. through reference in this text, constitute provisions of this part of IEC 645. At the time of publication, the editions indicated were valid. All normative documents are subject to revision, and parties to agreements based on this
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN6064521997ENAUDIOMETERSPART2EQUIPMENTFORSPEECHAUDIOMETRY 听力 部分 语言 装置 IEC64521993PDF

链接地址:http://www.mydoc123.com/p-718531.html