EN 60584-3-2008 en Thermocouples - Part 3 Extension and compensating cables - Tolerances and identification system《热电偶 第3部分 外延和补偿缆线 公差和鉴定体系[替代 CENELEC HD 446 3 S1]》.pdf
《EN 60584-3-2008 en Thermocouples - Part 3 Extension and compensating cables - Tolerances and identification system《热电偶 第3部分 外延和补偿缆线 公差和鉴定体系[替代 CENELEC HD 446 3 S1]》.pdf》由会员分享,可在线阅读,更多相关《EN 60584-3-2008 en Thermocouples - Part 3 Extension and compensating cables - Tolerances and identification system《热电偶 第3部分 外延和补偿缆线 公差和鉴定体系[替代 CENELEC HD 446 3 S1]》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 60584-3:2008Thermocouples Part 3: Extension and compensating cables Tolerances and identification systemICS 17.200.20g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g
2、3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 60584-3:2008This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 March 2008 BSI 2008ISBN 978 0 580 54650 1National forewordThis British Standard is the UK implementation of EN 60584-3:2008. It is ide
3、ntical to IEC 60584-3:2007. It supersedes BS 4937-30:1993 which is withdrawn.The UK participation in its preparation was entrusted by Technical Committee GEL/65, Measurement and control, to Subcommittee GEL/65/2, Elements of systems.A list of organizations represented on this committee can be obtain
4、ed on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations. Amendments/corrigenda issued since publicationDa
5、te CommentsEUROPEAN STANDARD EN 60584-3 NORME EUROPENNE EUROPISCHE NORM January 2008 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brus
6、sels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60584-3:2008 E ICS 17.200.20 Supersedes HD 446.3 S1:1993English version Thermocouples - Part 3: Extension and compensating cables - Tolerances and identification system (IE
7、C 60584-3:2007) Couples thermolectriques - Partie 3: Cbles dextension et de compensation - Tolrances et systme didentification (CEI 60584-3:2007) Thermopaare - Teil 3: Thermoleitungen und Ausgleichsleitungen - Grenzabweichungen und Kennzeichnungssystem (IEC 60584-3:2007) This European Standard was a
8、pproved by CENELEC on 2007-12-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such n
9、ational standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own lang
10、uage and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Lat
11、via, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 60584-3:2008 Foreword The text of document 65B/642/FDIS, future edition 2 of IEC 60584-3, prepared by SC 65B, Devices and process analysis,
12、 of IEC TC 65, Industrial-process measurement, control and automation, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60584-3 on 2007-12-01. This European Standard supersedes HD 446.3 S1:1993. The main technical changes with regard to HD 446.3 S1:1993 are as follows
13、: addition of Subclause 5.4 Connectors; addition of Clauses 7 Dimensions and 8 Requirements. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2008-09-01 latest date by which th
14、e national standards conflicting with the EN have to be withdrawn (dow) 2010-12-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 60584-3:2007 was approved by CENELEC as a European Standard without any modification. _ 2 THERMOCOUPLES Part 3: Exten
15、sion and compensating cables Tolerances and identification system 1 Scope This part of IEC 60584 specifies manufacturing tolerances for extension and compensating cables (other than mineral insulated cables) provided directly to users of industrial processes. These tolerances are determined with res
16、pect to the e.m.f.-temperature relationship of Part 1 of the standard. The method for identification of insulated thermocouple extension and compensating cables other than mineral insulated cables is described. Furthermore, requirements for extension and compensating cables for use in industrial pro
17、- cess control are specified. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) appli
18、es. IEC 60584-1:1995, Thermocouples Part 1: Reference tables 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 extension and compensating cables are used for the electrical connection between the open ends of a thermocouple and the ref-erence j
19、unction in those installations where the conductors of the thermocouple are not di-rectly connected to the reference junction. The thermoelectric properties of extension and compensating cables shall be close to the properties of the corresponding thermocouple. 3.1.1 extension cables are manufacture
20、d from conductors having the same nominal composition as those of the cor-responding thermocouple. They are designated by the letter “X“ following the designation of the thermocouple, for example “JX“. 3.1.2 compensating cables are manufactured from conductors having a composition different from the
21、 corresponding thermocouple. They are designated by the letter “C“ following the designation of the thermo-couple, for example “KC“. In some cases different tolerances apply for the same thermocou-ple type over different temperature ranges. These are distinguished by additional letters such as, for
22、example, KCA and KCB. 3 EN 60584-3:20083.2 tolerance the tolerance of an extension or compensating cable is the maximum additional deviation in microvolts caused by the introduction of the extension or compensating cable into the meas-uring circuit. 4 Tolerance values Table 1 shows the specified tol
23、erance for extension and compensating cables when used at temperatures within the ranges indicated as “Cable temperature range“. Table 1 Tolerance classes for extension and compensating cables Tolerance class Type 1 2 Cable temperature range Measuring junctiontemperature JX 85 V (1,5 C) 140 V (2,5 C
24、) 25 C to +200 C 500 C TX 30 V (0,5 C) 60 V (1,0 C) 25 C to +100 C 300 C EX 120 V (1,5 C) 200 V (2,5 C) 25 C to +200 C 500 C KX 60 V (1,5 C) 100 V (2,5 C) 25 C to +200 C 900 C NX 60 V (1,5 C) 100 V (2,5 C) 25 C to +200 C 900 C KCA 100 V (2,5 C) 0 C to +150 C 900 C KCB 100 V (2,5 C) 0 C to +100 C 900
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN6058432008ENTHERMOCOUPLESPART3EXTENSIONANDCOMPENSATINGCABLESTOLERANCESANDIDENTIFICATIONSYSTEM 热电偶 部分

链接地址:http://www.mydoc123.com/p-718378.html