EN 60512-11-2-2002 en Connectors for Electronic Equipment - Tests and Measurements Part 11-2 Climatic Tests - Test 11b Combined Sequential Cold Low Air Pressure and Damp Heat《电子设备用.pdf
《EN 60512-11-2-2002 en Connectors for Electronic Equipment - Tests and Measurements Part 11-2 Climatic Tests - Test 11b Combined Sequential Cold Low Air Pressure and Damp Heat《电子设备用.pdf》由会员分享,可在线阅读,更多相关《EN 60512-11-2-2002 en Connectors for Electronic Equipment - Tests and Measurements Part 11-2 Climatic Tests - Test 11b Combined Sequential Cold Low Air Pressure and Damp Heat《电子设备用.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD Connectors for electronic equipment Tests and measurements Part 11-2: Climatic tests- Test 1 1 b: Combined/sequential cold, low air pressure and damp heat The European Standard EN 605 12-1 1-2:2002 has the status of a British Standard ICs 31.220.10 BS EN 605 12-1 1-21 2002 WkNb A%“
2、U- rn% E rn NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW $ present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments a
3、nd promulgate them in the UK. - A list of organizations represented on this subcommittee can be obtained on request to its secretary. From 1 January 1997, all IEC publications have the number 60000 added to the old number. For instance, IEC 27-1 has been renumbered as IEC 60027-1. For a period oftim
4、e during the change over from one numbering system to the other, publications may contain identifiers from both systems. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the se
5、ction entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct applicatio
6、n. Compliance with a British Standard does not ofitself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 5 and a back cover. The BSI copyright date displayed in this document indicates when the docume
7、nt was last issued. O BSI 23 May 2002 ISBN O 580 39703 3 EUROPEAN STANDARD EN 60512-1 1-2 NORME EUROPENNE EUROPISCHE NORM April 2002 ICs 31.220.10 English version Connectors for electronic equipment - Tests and measurements Part 11-2: Climatic tests - Test 11 b: Combined/sequential cold, low air pre
8、ssure and damp heat (IEC 6051 2-1 1-212002) Connecteurs pour quipements lectroniques - Essais et mesures Partie 11-2: Essais climatiques - Essai 11 b: Essai combin squentiel de froid, basse pression atmosphrique et chaleur humide (CE1 60512-1 1-212002) Steckverbinder fr elektronische Einrichtungen -
9、 Mess- und Prfverfahren Teil 11 -2: Klimatische Prfungen - Prfung 11 b: Kombinierte Prfung Klte, Unterdruck und feuchte Wrme (IEC 60512-1 1-212002) This European Standard was approved by CENELEC on 2002-04-01. CENELEC members are bound to comply with the CENKENELEC Internal Regulations which stipula
10、te the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard
11、exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national e
12、lectrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit E
13、uropen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels O 2002 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60512-11-2:2002 E Page 2 E
14、N 60512-11-22002 Foreword The text of document 48B/1143/FDIS, future edition 1 of IEC 60512-1 1-2, prepared by SC 48B, Connectors, of IEC TC 48, Electromechanical components and mechanical structures for electronic equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC
15、 as EN 60512-1 1-2 on 2002-04-01. The following dates were fixed: - latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement - latest date by which the national standards conflicting with the EN have to be withdrawn Annexe
16、s designated “normative“ are part of the body of the standard. In this standard, annex ZA is normative. Annex ZA has been added by CENELEC. (dop) 2003-01-01 (dow) 2005-04-01 Endorsement notice The text of the International Standard IEC 60512-11-2:2002 was approved by CENELEC as a European Standard w
17、ithout any modification. O BSI 23 May 2002 Page 3 EN 60512-11-22002 CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - Part 11-2: Climatic tests - Test 11 b: Combined/sequential cold, low air pressure and damp heat 1 General 1.1 Scope and object This part of IEC 60512, when required by t
18、he detail specification, is used for testing electromechanical components within the scope of IEC technical committee 48. This test may also be used for similar devices when specified in a detail specification. The object of this test is to define a standard test method to assess the ability of comp
19、onents to function in a specified manner, during and after subjection to the conditions which prevail to some extent everywhere in an aircraft during ascent and descent, but which are particularly severe in unheated andlor unpressurized zones. 1.2 Normative references The following referenced docume
20、nts are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60068-2-39:1976, Environmenfal fesfing - Parf 2: Tesfs - Tesf ZIAMD: Combine
21、d sequenfial cold, low air pressure, and damp heaf fesf 2 Preparation 2.1 Preparation of the specimen When required by the detail specification, the specimen shall be mated and unmated as many times as specified prior to testing. For each test carried out, the detail specification shall specify the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN605121122002ENCONNECTORSFORELECTRONICEQUIPMENTTESTSANDMEASUREMENTSPART112CLIMATICTESTSTEST11BCOMBINEDSEQUENTIALCOLDLOWAIRPRESSUREANDDAMPHEAT

链接地址:http://www.mydoc123.com/p-718222.html