EN 60318-6-2008 en Electroacoustics - Simulators of human head and ear - Part 6 Mechanical coupler for the measurement of bone vibrators《电声学 人头部和耳朵模拟器 第6部分 骨振动器测量用机械耦合器[替代 CENELEC .pdf
《EN 60318-6-2008 en Electroacoustics - Simulators of human head and ear - Part 6 Mechanical coupler for the measurement of bone vibrators《电声学 人头部和耳朵模拟器 第6部分 骨振动器测量用机械耦合器[替代 CENELEC .pdf》由会员分享,可在线阅读,更多相关《EN 60318-6-2008 en Electroacoustics - Simulators of human head and ear - Part 6 Mechanical coupler for the measurement of bone vibrators《电声学 人头部和耳朵模拟器 第6部分 骨振动器测量用机械耦合器[替代 CENELEC .pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 60318-6:2008Electroacoustics Simulators of human head and ear Part 6: Mechanical coupler for the measurement of bone vibratorsICS 17.140.50g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g4
2、4g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 60318-6:2008This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 September 2008 BSI 2008ISBN 978 0 580 55013 3National forewordThis British Standard is the UK implementation of
3、EN 60318-6:2008. It is identical to IEC 60318-6:2007. It supersedes BS 4009:1991 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee EPL/29, Electroacoustics.A list of organizations represented on this committee can be obtained on request to its secretary.
4、This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations. Amendments/corrigenda issued since publicationDate CommentsEUROPEAN STANDARD EN
5、 60318-6 NORME EUROPENNE EUROPISCHE NORM July 2008 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of
6、exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60318-6:2008 E ICS 17.140.50 Supersedes HD 590 S1:1991English version Electroacoustics - Simulators of human head and ear - Part 6: Mechanical coupler for the measurement of bone vibrators (IEC 60318-6:2007
7、) Electroacoustique - Simulateurs de tte et doreille humaines -Partie 6: Coupleur mcanique destin la mesure des ossivibrateurs (CEI 60318-6:2007) Akustik - Simulatoren des menschlichen Kopfes und Ohres - Teil 6: Mechanischer Kuppler fr Messungen an Knochenleitungshrern(IEC 60318-6:2007) This Europea
8、n Standard was approved by CENELEC on 2008-06-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references c
9、oncerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member i
10、nto its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ire
11、land, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Foreword The text of document 29/615/CDV, future edition 1 of IEC 60318-6, prepared by IEC TC 29, Electroacoustics, was submit
12、ted to the IEC-CENELEC parallel Unique Acceptance Procedure and was approved by CENELEC as EN 60318-6 on 2008-06-01. This European Standard supersedes HD 590 S1:1991. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical na
13、tional standard or by endorsement (dop) 2009-03-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2011-06-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 60318-6:2007 was approved by CENELEC as a E
14、uropean Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60118-9 NOTE Harmonized as HD 450.9 S1:1987 (not modified). IEC 60645-1 NOTE Harmonized as EN 60645-1:2001 (not modified). ISO 389-3 NOTE Harmon
15、ized as EN ISO 389-3:1998 (not modified). ISO 266 NOTE Harmonized as EN ISO 266:1997 (not modified). _ BS EN 60318-6:2008 2 CONTENTS 1 Scope.4 2 Normative reference .4 3 Terms and definitions .4 4 Construction.5 4.1 General .5 4.2 Mechanical impedance level6 4.3 Phase angle of mechanical impedance7
16、4.4 External geometry .7 5 Calibration7 5.1 Reference environmental conditions7 5.2 Calibration procedure 7 5.3 Force sensitivity level7 5.4 Mechanical impedance level8 5.5 Temperature dependence8 6 Marking and instruction manual 8 6.1 Marking of the mechanical coupler 8 6.2 Instruction manual.8 7 C
17、oupling of bone vibrator to the mechanical coupler.8 8 Maximum permitted expanded uncertainty of measurements 10 Annex A (informative) Example of a specific construction of a mechanical coupler.10 Annex B (informative) Guidance on the testing and calibration of mechanical couplers 13 Bibliography14
18、Figure A.1 Dimensions of mechanical impedance element base.11 Figure A.2 Dimensions of tungsten loading insert.11 Figure A.3 Assembly of the mechanical coupler .12 Table 1 Mechanical impedance level6 Table 2 Values of Umaxfor basic measurements 9 Annex ZA (normative) Normative references to internat
19、ional publications with theircorresponding European publications15BS EN 60318-6:2008 3 ELECTROACOUSTICS SIMULATORS OF HUMAN HEAD AND EAR Part 6: Mechanical coupler for the measurement of bone vibrators 1 Scope This part of IEC 60318 describes a mechanical coupler for the measurement of the output fo
20、rce of bone vibrators. The mechanical impedance of the coupler is specified in the frequency range 125 Hz to 8 000 Hz. The coupler is intended for calibration of audiometers using bone vibrators having a plane circular tip area of 175 mm 25 mm and for determining the performance of bone conduction h
21、earing aids. The vibratory force developed by a bone vibrator is not, in general, the same on the coupler as on a persons mastoid. However, the IEC recommends its use as a means for the calibration of specified vibrators used in audiometry and for the exchange of specifications and of data on bone c
22、onduction hearing aids. NOTE Some bone vibrators of hearing aids and some non-standardised bone vibrators still used in audiometry have a curved surface. Users should be aware that those vibrators in general will not be loaded on the mechanical coupler with the same mechanical impedance as the one s
23、pecified in Table 1 of this standard. 2 Normative reference The following referenced document is indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments)
24、applies. BIPM, IEC, ISO, IFCC, IUPAC, IUPAP and OIML:1995, Guide to the expression of uncertainty in measurement (GUM) 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 bone-conduction vibrator bone vibrator electro-mechanical transducer that t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN6031862008ENELECTROACOUSTICSSIMULATORSOFHUMANHEADANDEARPART6MECHANICALCOUPLERFORTHEMEASUREMENTOFBONEVIBRATORS

链接地址:http://www.mydoc123.com/p-717903.html