EN 60300-3-12-2011 en Dependability management - Part 3-12 Application guide - Integrated logistic support《可靠性管理 第3-12部分 应用指南 集成逻辑支持》.pdf
《EN 60300-3-12-2011 en Dependability management - Part 3-12 Application guide - Integrated logistic support《可靠性管理 第3-12部分 应用指南 集成逻辑支持》.pdf》由会员分享,可在线阅读,更多相关《EN 60300-3-12-2011 en Dependability management - Part 3-12 Application guide - Integrated logistic support《可靠性管理 第3-12部分 应用指南 集成逻辑支持》.pdf(56页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationDependability managementPart 3-12: Application guide Integrated logistic supportBS EN 60300-3-12:2011National forewordThis British Standard is the UK implementation of EN 60300-3
2、-12:2011. It is identical to IEC 60300-3-12:2011. It supersedes BS EN 60300-3-12:2004 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee DS/1, Dependability and value management.A list of organizations represented on this committee can be obtained on requ
3、est to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. BSI 2011ISBN 978 0 580 63342 3 ICS 03.120.30; 21.020 Compliance with a British Standard cannot confer immunity from legal obligations.This
4、British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 July 2011.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 60300-3-12:2011EUROPEAN STANDARD EN 60300-3-12 NORME EUROPENNE EUROPISCHE NORM March 2011 CENELEC Euro
5、pean Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CE
6、NELEC members. Ref. No. EN 60300-3-12:2011 E ICS 03.120.30; 21.020 Supersedes EN 60300-3-12:2004English version Dependability management - Part 3-12: Application guide - Integrated logistic support (IEC 60300-3-12:2011) Gestion de la sret de fonctionnement - Partie 3-12: Guide dapplication - Soutien
7、 logistique intgr (CEI 60300-3-12:2011) Zuverlssigkeitsmanagement - Teil 3-12: Anwendungsleitfaden - Integrierte logistische Untersttzung (IEC 60300-3-12:2011) This European Standard was approved by CENELEC on 2011-03-24. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations
8、which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This Europ
9、ean Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are t
10、he national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Sloven
11、ia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 60300-3-12:2011EN 60300-3-12:2011 - 2 - Foreword The text of document 56/1398/FDIS, future edition 2 of IEC 60300-3-12, prepared by IEC TC 56, Dependability, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN
12、60300-3-12 on 2011-03-24. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. This European Standard supersedes EN 60300-3-12:2004. EN 60300-
13、3-12:2011 includes the following significant technical changes with respect to EN 60300-3-12:2004: provision of a better overview of the whole ILS process; updating of the document to align with associated dependability standards that were introduced after EN 60300-3-12:2004. The following dates wer
14、e fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2011-12-24 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2014-03-24 Annex ZA has been added by CENELE
15、C. _ Endorsement notice The text of the International Standard IEC 60300-3-12:2011 was approved by CENELEC as a European Standard without any modification. _ BS EN 60300-3-12:2011- 3 - EN 60300-3-12:2011 Annex ZA (normative) Normative references to international publications with their corresponding
16、 European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international
17、 publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60050-191 - International Electrotechnical Vocabulary (IEV) - Chapter 191: Dependability and quality of service - - IEC 60300-3-1 - Dependability management -
18、 Part 3-1: Application guide - Analysis techniques for dependability - Guide on methodology EN 60300-3-1 - IEC 60300-3-2 - Dependability management - Part 3-2: Application guide - Collection of dependability data from the field EN 60300-3-2 - IEC 60300-3-3 - Dependability management - Part 3-3: Appl
19、ication guide - Life cycle costingEN 60300-3-3 - IEC 60300-3-4 - Dependability management - Part 3-4: Application guide - Guide to the specification of dependability requirements EN 60300-3-4 - IEC 60300-3-10 - Dependability management - Part 3-10: Application guide - Maintainability - - IEC 60300-3
20、-11 - Dependability management - Part 3-11: Application guide - Reliability centred maintenance EN 60300-3-11 - IEC 60300-3-14 - Dependability management - Part 3-14: Application guide - Maintenance and maintenance support EN 60300-3-14 - IEC 60300-3-16 - Dependability management - Part 3-16: Applic
21、ation guide - Guidelines for specification of maintenance support servicesEN 60300-3-16 - IEC 60706-2 - Maintainability of equipment - Part 2: Maintainability requirements and studies during the design and development phase EN 60706-2 - IEC 60706-3 - Maintainability of equipment - Part 3: Verificati
22、on and collection, analysis and presentation of data EN 60706-3 - IEC 60706-5 - Maintainability of equipment - Part 5: Testability and diagnostic testing EN 60706-5 - IEC 60812 - Analysis techniques for system reliability - Procedure for failure mode and effects analysis (FMEA) EN 60812 - IEC 61160
23、- Design review EN 61160 - BS EN 60300-3-12:2011EN 60300-3-12:2011 - 4 - Publication Year Title EN/HD Year IEC 62402 - Obsolescence management - Application guide EN 62402 - IEC 62508 - Guidance on human aspects of dependability EN 62508 - BS EN 60300-3-12:2011 60300-3-12 IEC:2011 2 CONTENTS INTRODU
24、CTION . 7 1 Scope . 8 2 Normative references . 8 3 Terms, definitions and abbreviations 9 3.1 Terms and definitions 9 3.2 Abbreviations 10 4 Principles of integrated logistic support (ILS) 11 4.1 ILS objectives 11 4.2 Application of ILS 11 4.3 Elements of ILS . 12 4.4 Structure of ILS . 13 5 Plannin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN603003122011ENDEPENDABILITYMANAGEMENTPART312APPLICATIONGUIDEINTEGRATEDLOGISTICSUPPORT 可靠性 管理 312 部分

链接地址:http://www.mydoc123.com/p-717816.html