EN 60099-9-2014 en Surge arresters - Part 9 Metal-oxide surge arresters without gaps for HVDC converter stations.pdf
《EN 60099-9-2014 en Surge arresters - Part 9 Metal-oxide surge arresters without gaps for HVDC converter stations.pdf》由会员分享,可在线阅读,更多相关《EN 60099-9-2014 en Surge arresters - Part 9 Metal-oxide surge arresters without gaps for HVDC converter stations.pdf(94页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationSurge arrestersPart 9: Metal-oxide surge arresters without gaps for HVDC converter stationsBS EN 60099-9:2014National forewordThis British Standard is the UK implementation of EN 60099-9:2014. It isidentical to IEC 60099-9:2014.The UK participation in its preparation was ent
2、rusted to TechnicalCommittee PEL/37, Surge Arresters - High Voltage.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct applicati
3、on. The British Standards Institution 2014.Published by BSI Standards Limited 2014ISBN 978 0 580 73982 8ICS 29.120.50; 29.240.10Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy
4、Committee on 30 September 2014. Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 60099-9:2014EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 60099-9 September 2014 ICS 29.240.10; 29.120.50 English Version Surge arresters - Part 9: Metal-oxide surge arresters wi
5、thout gaps for HVDC converter stations (IEC 60099-9:2014) Parafoudres - Partie 9: Parafoudres oxyde mtalliquesans clateur pour postes de conversion CCHT (CEI 60099-9:2014) berspannungsableiter - Teil 9: Metalloxidableiter ohneFunkenstrecken fr HG-Stromrichterstationen (IEC 60099-9:2014) This Europea
6、n Standard was approved by CENELEC on 2014-07-31. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references c
7、oncerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELE
8、C member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Re
9、public of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,Turkey and the United Kingdom. European Committee for Electrotechnical Standardizat
10、ion Comit Europen de Normalisation ElectrotechniqueEuropisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 60099-9:2014 E
11、 EN 60099-9:2014 - 2 - Foreword The text of document 37/417/FDIS, future edition 1 of IEC 60099-9, prepared by IEC/TC 37 “Surge arresters“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60099-9:2014. The following dates are fixed: latest date by which the document has t
12、o be implemented at national level by publication of an identical national standard or by endorsement (dop) 2015-05-01 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2017-07-31 Attention is drawn to the possibility that some of the elements of th
13、is document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 60099-9:2014 was approved by CENELEC as a European Standard without any modification. In the
14、official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60071-1 NOTE Harmonized as EN 60071-1. IEC 60143-1 NOTE Harmonized as EN 60143-1. IEC 60633:1998 NOTE Harmonized as EN 60633:1999 (not modified). IEC 60507 NOTE Harmonized as EN 60507. IEC 62271
15、-1:2007 NOTE Harmonized as EN 62271-1:2008 (not modified). ISO 4892-1 NOTE Harmonized as EN ISO 4892-1. ISO 4892-2 NOTE Harmonized as EN ISO 4892-2. ISO 4892-3 NOTE Harmonized as EN ISO 4892-3. BS EN 60099-9:2014- 3 - EN 60099-9:2014 Annex ZA (normative) Normative references to international publica
16、tions with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced
17、 document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here: www
18、.cenelec.eu. Publication Year Title EN/HD Year IEC 60060-1 - High-voltage test techniques - Part 1: General definitions and test requirements EN 60060-1 - IEC 60060-2 - High-voltage test techniques - Part 2: Measuring systems EN 60060-2 - IEC 60068-2-11 1981 Environmental testing - Part 2: Tests - T
19、est Ka: Salt mist EN 60068-2-11 1999 IEC 60068-2-14 - Environmental testing - Part 2-14: Tests - Test N: Change of temperature EN 60068-2-14 - IEC 60068-2-17 - Environmental testing - Part 2: Tests - Test Q: Sealing EN 60068-2-17 - IEC 60071-2 1996 Insulation co-ordination - Part 2: Application guid
20、e EN 60071-2 1997 IEC 60099-4 (mod) 2004 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems EN 60099-4 2004 IEC 60143-2 - Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks EN 60143-2 - IEC 60270 - High-voltage test techniqu
21、es - Partial discharge measurements EN 60270 - IEC 60721-3-2 - Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation EN 60721-3-2 - IEC 62217 - Polymeric HV insulators for indoor and outdoor use - Ge
22、neral definitions, test methods and acceptance criteria EN 62217 - BS EN 60099-9:2014EN 60099-9:2014 - 4 - Publication Year Title EN/HD Year IEC 62271-200 2011 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and
23、 including 52 kV EN 62271-200 2012 IEC 62271-203 2011 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV EN 62271-203 2012 IEC/TS 60071-5 2002 Insulation co-ordination - Part 5: Procedures for high-voltage direct current (HVDC)
24、converter stations - - IEC/TS 60815-2 - Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems - - CISPR 16-1-1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN6009992014ENSURGEARRESTERSPART9METALOXIDESURGEARRESTERSWITHOUTGAPSFORHVDCCONVERTERSTATIONSPDF

链接地址:http://www.mydoc123.com/p-717612.html