EN 55016-2-3-2010 en Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3 Methods of measurement of disturbances and immunity - Radiated dist.pdf
《EN 55016-2-3-2010 en Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3 Methods of measurement of disturbances and immunity - Radiated dist.pdf》由会员分享,可在线阅读,更多相关《EN 55016-2-3-2010 en Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3 Methods of measurement of disturbances and immunity - Radiated dist.pdf(104页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationSpecification for radio disturbance and immunity measuring apparatus and methodsPart 2-3: Methods of measurement of disturbances and immunity Radiated disturbance measurementsBS EN 55016-2-3:2010+A1:2010BS EN 55016-2-3:2010+A2:2014Incorporating corrigendum September 2013BS E
2、N 55016-2-3:2010+A2:2014National forewordThis British Standard is the UK implementation of EN 55016-2-3:2010+A2:2014. It is identical to CISPR 16-2-3:2010, incorporating amendments 1:2010 and 2:2014. It supersedes BS EN 55016-2-3:2010+A1:2010, which will be withdrawn on 18 April 2017.BSI as a member
3、 of CENELEC, is obliged to publish the second amendment to EN 55016-2-3:2010+A2 as a British Standard. However, attention is drawn to the fact that during the development of this European Standard, the UK committee voted against its approval as a European Standard. The concern in amendment 2 clause
4、7.3.6.3 is that it does not provide a representative simulation of mains cabling. The UK will continue to work to improve this standard and its application to dependent standards. Technical justification was presented at the Tokyo EMC conference in May 2014 in the paper: ”Measurement Method, Uncerta
5、inty and Cable Balance - with Implications for the CDNE-M” by D M Lauder 33.100.20Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 May 2011.Amendments/corrigen
6、da issued since publicationDate Text affected30 June 2011 Implementation of CISPR Amendment 1:2010 with CENELEC endorsement A1:201030 September 2013 Supersession information removed from EN title page30 September 2014 Implementation of CISPR amendment 2:2014 with CENELEC endorsement A2:2014BRITISH S
7、TANDARDEUROPEAN STANDARD EN 55016-2-3NORME EUROPENNE EUROPISCHE NORM CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2010 CENELEC -
8、All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 55016-2-3:2010 E ICS 33.100.10; 33.100.20 Supersedes EN 55016-2-3:2006English version Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of me
9、asurement of disturbances and immunity - Radiated disturbance measurements (CISPR 16-2-3:2010) Spcifications des mthodes et des appareils de mesure des perturbations radiolectriques et de limmunit aux perturbations radiolectriques - Partie 2-3: Mthodes de mesure des perturbations et de limmunit - Me
10、sures des perturbations rayonnes (CISPR 16-2-3:2010) Anforderungen an Gerte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Straussendung (Funkstrungen) und Strfestigkeit - Teil 2-3: Verfahren zur Messung der hochfrequenten Straussendung (Funkstrungen) und Strfestigke
11、it - Messung der gestrahlten Straussendung(CISPR 16-2-3:2010) This European Standard was approved by CENELEC on 2010-06-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard
12、 without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other l
13、anguage made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech
14、Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. :2010+A2 June 2014 Foreword The text of doc
15、ument CISPR/A/886/FDIS, future edition 3 of CISPR 16-2-3, prepared by CISPR SC A, Radio-interference measurements and statistical methods, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 55016-2-3 on 2010-06-01. This European Standard supersedes EN 55016-2-3:2006. Th
16、is EN 55016-2-3:2010 includes the following significant technical changes with respect to EN 55016-2-3:2006: addition of the measurand for radiated emissions measurements in an OATS and a SAC in the range of 30 MHz to 1 000 MHz, and addition of a new normative annex on the determination of suitabili
17、ty of spectrum analysers for compliance tests. Also, numerous maintenance items are addressed to make the standard current with respect to other parts of the EN 55016 series. It has the status of a basic EMC publication in accordance with IEC Guide 107, Electromagnetic compatibility Guide to the dra
18、fting of electromagnetic compatibility publications. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following dates were fixed: late
19、st date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2011-03-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2013-06-01 Annex ZA has been added by CENELEC. _ Endorsem
20、ent notice The text of the International Standard CISPR 16-2-3:2010 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: 1 CISPR 11:2009 NOTE Harmonized as EN 55011:2009 (
21、modified). 3 CISPR 22:2008 NOTE Harmonized as EN 55022:200X 1)(modified). 4 IEC 61140:2001 NOTE Harmonized as EN 61140:2002 (not modified). 6 ISO/IEC 17000:2004 NOTE Harmonized as EN ISO/IEC 17000:2004 (not modified). 7 IEC 61000-4-21 NOTE Harmonized as EN 61000-4-21. _ 1)At draft stage.Foreword to
22、amendment A1 The text of document CISPR/A/878/CDV, future amendment 1 to CISPR 16-2-3:2010, prepared by CISPR SC A, Radio-interference measurements and statistical methods, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as amendment A1 to EN 55016-2-3:2010 on 2010-10-01.
23、Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following dates were fixed: latest date by which the amendment has to be implemented
24、at national level by publication of an identical national standard or by endorsement (dop) 2011-07-01 latest date by which the national standards conflicting with the amendment have to be withdrawn (dow) 2013-10-01 _ Endorsement notice The text of amendment 1:2010 to the International Standard IEC 5
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN55016232010ENSPECIFICATIONFORRADIODISTURBANCEANDIMMUNITYMEASURINGAPPARATUSANDMETHODSPART23METHODSOFMEASUREMENTOFDISTURBANCESANDIMMUNITYRADIATEDDISTPDF

链接地址:http://www.mydoc123.com/p-717390.html