EN 50441-3-2006 en Cables for indoor residential telecommunication installations Part 3 Screened cables - Grade 3《室内住宅通信装置用电缆 第3部分 3级屏蔽电缆》.pdf
《EN 50441-3-2006 en Cables for indoor residential telecommunication installations Part 3 Screened cables - Grade 3《室内住宅通信装置用电缆 第3部分 3级屏蔽电缆》.pdf》由会员分享,可在线阅读,更多相关《EN 50441-3-2006 en Cables for indoor residential telecommunication installations Part 3 Screened cables - Grade 3《室内住宅通信装置用电缆 第3部分 3级屏蔽电缆》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 50441-3:2006Cables for indoor residential telecommunication installations Part 3: Screened cables Grade 3The European Standard EN 50144-3:2006 has the status of a British StandardICS 33.120.10g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54
2、g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 50441-3:2006This British Standard was published under the authority of the Standards Policy and Strategy Committee on 29 September 2006 BSI 2006ISBN 0 580 49120 XNational forewordT
3、his British Standard was published by BSI. It is the UK implementation of EN 50441-3:2006.The UK participation in its preparation was entrusted to Technical Committee EPL/46, Cables, wires and waveguides, radio frequency connectors and accessories for communication and signalling. A list of organiza
4、tions represented on EPL/46 can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendmen
5、ts issued since publicationAmd. No. Date CommentsEUROPEAN STANDARD EN 50441-3 NORME EUROPENNE EUROPISCHE NORM June 2006 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat
6、: rue de Stassart 35, B - 1050 Brussels 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50441-3:2006 E ICS 33.120.10 English version Cables for indoor residential telecommunication installations Part 3: Screened cables - Grad
7、e 3 Cbles pour les installations rsidentielles de tlcommunications en intrieur Partie 3: Cbles crants - Classe 3 Innenkabel fr Telekommunikationseinrichtungen im Wohnbereich Teil 3: Geschirmte Innenkabel - Klasse 3 This European Standard was approved by CENELEC on 2005-12-06. CENELEC members are bou
8、nd to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the C
9、entral Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same
10、 status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
11、 Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 50441-3:2006 - 2 - Foreword This European Standard was prepared by SC 46XC, Multicore, Multipair and Quad Data communication cables, of Technical Committee CENELEC TC 46X, Communication cables. The text of
12、the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as EN 50441-3 on 2005-12-06. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2007-01-01
13、latest date by which the national standards conflicting with the EN have to be withdrawn (dow)2009-01-01 _ - 3 - EN 50441-3:2006 Contents 1 Scope 5 2 Normative references 5 3 Quality control 6 4 Cable construction 7 4.1 Conductors. 7 4.1.1 Conductor construction. 7 4.1.2 Conductor Type . 7 4.2 Insul
14、ation . 7 4.2.1 Insulation material 7 4.2.2 Thickness of the insulation 7 4.2.3 Colour of the insulated conductor 7 4.3 Cable element 7 4.4 Screening of the cable element 7 4.5 Cabling 7 4.6 Spare pairs 8 4.7 Colour code 8 4.8 Screening and wrapping of the core . 8 4.8.1 Core wrapping . 8 4.8.2 Scre
15、en 8 4.9 Sheath. 8 4.9.1 Sheath material 8 4.9.2 Sheath construction 8 4.9.3 Thickness of the sheath 8 4.10 Ripcord 9 4.11 Overall diameter . 9 4.12 Identification. 9 4.12.1 Sheath marking 9 4.12.2 Identification thread 9 4.13 Delivery length 10 4.13.1 Labelling 10 4.13.2 End caps. 10 5 Mechanical r
16、equirements. 10 5.1 Conductor 10 5.2 Insulation . 10 5.3 Sheath. 10 5.4 Finished cable 10 5.4.1 Sheath integrity 10 5.4.2 Static bending radius 10 5.4.3 Abrasion resistance of the sheath 11 5.4.4 Kink test 11 5.4.5 Cut-through test . 11 5.4.6 Adhesion of the sheath . 11 EN 50441-3:2006 - 4 - 5.4.7 I
17、nstallation capability. . 11 6 Environmental and climatic requirements 14 6.1 Insulation . 14 6.2 Sheath. 14 6.3 Fire behaviour 14 7 Electrical requirements 14 7.1 Conductor resistance 14 7.2 Dielectric strength. 14 7.3 Insulation resistance . 14 7.4 High frequency characteristics . 14 7.4.1 Impedan
18、ce. 15 7.4.2 Return loss 15 7.4.3 Attenuation 15 7.4.4 Crosstalk. 16 7.5 Electromagnetic behaviour 16 7.5.1 Transfer impedance 16 7.5.2 Coupling attenuation. 17 7.6 Unbalance attenuation 17 7.7 Environmental and safety aspects 17 Figure 1 - Test fixture12 Figure 2 - Installation test system 13 Table
19、 1 - Cable impedance15 Table 2 - Minimum NEXT 16 - 5 - EN 50441-3:2006 1 Scope These cables are for installation in indoor Residential Cabling Systems. They are specified up to 1 000 MHz. Their design is based on the requirements of the EN 50290-2-1. They are specifically designed for cabling in res
20、idential environment supporting ICT and BCT applications. (Telephone, Computer and TV services). This specification defines the constructional details as well as the specific performances of the cables. Unless otherwise specified, all cables covered by this standard may be subjected to voltages not
21、more than 300 V a.c. or 450 V d.c. and shall meet the essential requirements of the low voltage directive. Due to current limitation related to the conductor cross sectional area, they are not intended for direct connection to mains electricity supply. The maximum current rating per conductor is les
22、s than or equal to 3 A/mm unless otherwise specified in the relevant detail specification. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest editio
23、n of the referenced document (including any amendments) applies. Publication Title EN 50265-2-1 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable Part 2-1: Procedures - 1 kW pre-mixed flame EN 50289-1-2
24、Communication cables - Specifications for test methods Part 1-2:Electrical test methods - DC resistance EN 50289-1-3 Communication cables - Specifications for test methods Part 1-3: Electrical test methods - Dielectric strength EN 50289-1-4 Communication cables - Specifications for test methods Part
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN5044132006ENCABLESFORINDOORRESIDENTIALTELECOMMUNICATIONINSTALLATIONSPART3SCREENEDCABLESGRADE3 室内 住宅

链接地址:http://www.mydoc123.com/p-717154.html