EN 50216-8-2005 en Power transformer and reactor fittings Part 8 Butterfly valves for insulating liquid circuits (Incorporates Amendment A1 2006)《电源变压器及电抗器配件 第8部分 绝缘液体电路用蝶阀 包含修改件1-.pdf
《EN 50216-8-2005 en Power transformer and reactor fittings Part 8 Butterfly valves for insulating liquid circuits (Incorporates Amendment A1 2006)《电源变压器及电抗器配件 第8部分 绝缘液体电路用蝶阀 包含修改件1-.pdf》由会员分享,可在线阅读,更多相关《EN 50216-8-2005 en Power transformer and reactor fittings Part 8 Butterfly valves for insulating liquid circuits (Incorporates Amendment A1 2006)《电源变压器及电抗器配件 第8部分 绝缘液体电路用蝶阀 包含修改件1-.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 50216-8:2005Incorporating amendment no. 1Power transformer and reactor fittings Part 8: Butterfly valves for insulating liquid circuitsThe European Standard EN 50216-8:2005, incorporating amendment A1:2006, has the status of a British StandardICS 23.060.30; 29.180g49g50g3g38g50
2、g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 50216-8:2005This British Standard was published under the authority of the Standards Policy and Strategy Com
3、mittee on 21 February 2006 BSI 2007ISBN 0 580 47665 0National forewordThis British Standard was published by BSI. It is the UK implementation of EN 50216-8:2005, incorporating amendment A1:2006.The start and finish of text introduced or altered by amendment is indicated in the text by tags !“. Tags
4、indicating changes to CEN text carry the number of the CEN amendment. For example, text altered by CEN amendment A1 is indicated by !“.The UK participation in its preparation was entrusted to Technical Committee PEL/14, Power transformers.A list of organizations represented on PEL/14 can be obtained
5、 on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments issued since publicationAmd. No. Date Co
6、mments16826 31 January 2007 See national forewordEUROPEAN STANDARD EN 50216-8 NORME EUROPENNE EUROPISCHE NORM May 2005 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat:
7、 rue de Stassart 35, B - 1050 Brussels 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50216-8:2005 E ICS 23.060.30; 29.180 English version Power transformer and reactor fittings Part 8: Butterfly valves for insulating liquid
8、 circuits Accessoires pour transformateurs de puissance et bobines dinductance Partie 8: Vannes papillon pour circuits liquides isolants Zubehr fr Transformatoren und Drosselspulen Teil 8: Drosselklappen fr Rohrleitungs-kreise mit Isolierflssigkeit This European Standard was approved by CENELEC on 2
9、004-12-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may b
10、e obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to th
11、e Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Ne
12、therlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. + A1 October 2006 EN 50216-8:2005 2 Foreword This European Standard was prepared by the Technical Committee CENELEC TC 14, Power transformers. The text of the draft was submitted to the Unique Acc
13、eptance Procedure and was approved by CENELEC as EN 50216-8 on 2004-12-01. This EN 50216-8 is to be read in conjunction with EN 50216-1. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsem
14、ent (dop) 2005-12-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2007-12-01 _ Foreword to amendment A1This amendment to the European Standard EN 50216-8:2005 was prepared by the Technical Committee CENELEC TC 14, Power transformers. The text of the
15、draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as amendment A1 to EN 50216-8:2005 on 2006-09-01. The following dates were fixed: latest date by which the amendment has to be implementedat national level by publication of an identical national standard or by endors
16、ement (dop) 2007-09-01 latest date by which the national standards conflicting with the amendment have to be withdrawn (dow) 2009-09-01 _ 3 EN 50216-8:2005 Contents 1 Scope 4 2 Normative references 4 3 Requirements and characteristics .4 3.1 Description 4 3.2 Operating characteristics.4 3.3 Componen
17、ts characteristics4 4 Assembly arrangements and dimensions .6 4.1 Types of assembly 6 4.2 Overall dimensions6 5 Dimensions and types of gaskets, dimensions of gasket seats 6 5.1 General6 5.2 Gaskets and gasket material.6 5.3 Admissible operating conditions7 5.4 Design criteria for gasket seats Choic
18、e of flange gaskets .7 6 Performances 9 6.1 Tightness of the mounted valve 9 6.2 Tightness of the butterfly blade .9 6.3 Operating torque .9 6.4 Maximum working overpressure with the butterfly valve in open and closed position 9 7 Tests10 7.1 Tightness of the mounted valve 10 7.2 Tightness of the bu
19、tterfly blade .10 7.3 Operating torque .10 7.4 Maximum working overpressure with the butterfly valve in open and closed position 10 8 Supply conditions.10 Figure 1 Assembly layout of butterfly valves type A1 and A2 11 Figure 2 Assembly layout of butterfly valves type B1 and B2 12 Figure 3 Assembly l
20、ayout of butterfly valves type C1 and C213 Figure 4 Dimensions of butterfly valves type A1 and A2 .14 Figure 5 Dimensions of butterfly valves type B115 Figure 6 Dimensions of butterfly valves type B216 Figure 7 Dimensions of butterfly valves type C117 Table 1 Flange gasket types and dimensions mm .8
21、 Table 2 Maximum admissible leakage value.9 Table 3 Operating torque.9 EN 50216-8:2005 4 1 Scope This standard covers the butterfly valves used on the pipelines, in which the insulating liquid of power transformers or reactors flows, in order to allow the replacement of components, without removing
22、the whole or a large amount of the insulating liquid from the conservator and the tank. This standard defines the general overall dimensions and some functional and manufacturing characteristics to guarantee interchangeability. 2 Normative references Addition to EN 50216-1: EN 1092-1 2001 Flanges an
23、d their joints Circular flanges for pipes, valves, fittings and accessories, PN designated Part 1: Steel flanges 3 Requirements and characteristics 3.1 Description The main components of a butterfly valve are: a flanged body, which allows the mounting on the pipe according to one of the assembly lay
24、outs listed in Clause 4. The free passage in the body gives the nominal dimension of the valve, which should be preferably within the range shown in the attached dimension tables. Except for the few exceptions shown in the tables, the flanged body has PN10 fixing dimensions, according to EN 1092-1;
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN5021682005ENPOWERTRANSFORMERANDREACTORFITTINGSPART8BUTTERFLYVALVESFORINSULATINGLIQUIDCIRCUITSINCORPORATESAMENDMENTA12006

链接地址:http://www.mydoc123.com/p-716823.html