EN 50193-2-2-2016 en Electric instantaneous water heaters - Part 2-2 Performance requirements - Single point of use electric instantaneous showers - Efficiency.pdf
《EN 50193-2-2-2016 en Electric instantaneous water heaters - Part 2-2 Performance requirements - Single point of use electric instantaneous showers - Efficiency.pdf》由会员分享,可在线阅读,更多相关《EN 50193-2-2-2016 en Electric instantaneous water heaters - Part 2-2 Performance requirements - Single point of use electric instantaneous showers - Efficiency.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN 50193-2-2:2016Electric instantaneous water heatersPart 2-2: Performance requirements Single point of use electric instantaneous showers EfficiencyBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS EN 50193-2-2:2016 BRITISH STANDARDNational forewordThis British
2、Standard is the UK implementation of EN 50193-2-2:2016.The UK participation in its preparation was entrusted to Technical Committee CPL/59, Performance of household electrical appliances.A list of organizations represented on this committee can be obtained on request to its secretary.This publicatio
3、n does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2017.Published by BSI Standards Limited 2017ISBN 978 0 580 83189 8 ICS 91.140.65 Compliance with a British Standard cannot confer immunity fr
4、om legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2017.Amendments/corrigendum issued since publicationDate T e x t a f f e c t e dBS EN 50193-2-2:2016EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 50193-2-2
5、 December 2016 ICS 91.140.65 English Version Electric instantaneous water heaters - Part 2-2: Performance requirements - Single point of use electric instantaneous showers - Efficiency Chauffe-eau lectriques instantans - Partie 2-2 : Exigences daptitude la fonction - Chauffe-eau instantans de douche
6、s un seul point dutilisation - Efficacit. Elektro-Durchfluss-Wassererwrmer - Teil 2-2: Anforderungen an die Gebrauchseigenschaften - Durchfluss-Wassererwrmer fr eine einzelne Zapfstelle - Effizienz This European Standard was approved by CENELEC on 2016-10-10. CENELEC members are bound to comply with
7、 the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Managem
8、ent Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the sa
9、me status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Li
10、thuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnis
11、che Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 50193-2-2:2016 EBS EN 50193-2-2:2016EN 50193-2-2:20162 Contents Page European foreword . 3 1 Scope . 4
12、 2 Normative references . 4 3 Terms and definitions. 4 4 General test conditions 4 5 Energy efficiency 4 5.1 Test method . 4 Annex A (normative) Load pattern 6 Annex B (normative) Test Set Up. 7 Annex ZZA (informative) Relationship between this European Standard and the energy labelling requirements
13、 of Commission Delegated Regulation (EU) No 812/2013 aimed to be covered 9 Annex ZZB (informative) Relationship between this European Standard and the ecodesign requirements of Commission Regulation (EU) No 814/2013 aimed to be covered 10 Bibliography 11 BS EN 50193-2-2:2016EN 50193-2-2:20163 Europe
14、an foreword This document (EN 50193-2-2) has been prepared by CLC/TC 59X “Performance of household and similar electrical appliances”. The following dates are fixed: latest date by which this document hasto be implemented at national level bypublication of an identical nationalstandard or by endorse
15、ment(dop) 2017-10-10 latest date by which the nationalstandards conflicting with thisdocument have to be withdrawn(dow) 2019-10-10 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC shall not be held responsible for identifyi
16、ng any or all such patent rights. For the relationship with EU Directive(s) see informative Annexes ZZA and ZZB, which are an integral part of this document. This document has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Association, and suppo
17、rts essential requirements of EU Directive(s). BS EN 50193-2-2:2016EN 50193-2-2:20164 1 Scope This clause of part 1 is applicable except as follows. Addition: This standard applies to open outlet, single point of use, electric instantaneous water heaters intended for household or similar use, for sh
18、owering purposes without downstream mixing. This standard only specifies tests for the assessment of energy efficiency. This standard does not apply to electrical instantaneous water heaters covered by other parts of this series of standards. 2 Normative references This clause of Part 1 is applicabl
19、e. 3 Terms and definitions This clause of Part 1 is applicable. 4 General test conditions This clause of Part 1 is applicable except as follows. 4.3 General conditions Addition: 4.3.101 Pressure, temperature, flow and power conditions Pressure, temperature and flow measurements should be maintained
20、during testing to the tolerance detailed in Table 1. Any deviations from these tolerances will result an invalid test. All testing should be performed at the rated power for the appliance (based on a rating at 230V/400V as applicable). 4.4 Test Setup Replacement: The appliance shall be fixed in acco
21、rdance with the installation instructions except that the shower hose shall not be connected. Products covered by this standard are only to be tested to the XS load pattern detailed in Annex A, Table A.1. The measurement setup shall correspond to Annex B. 5 Energy efficiency This clause of Part 1 is
22、 applicable except as follows. 5.1 Test method 5.1.1 General Addition It is allowable to decrease the time between draw offs in order to accelerate the load pattern detailed in Annex A, as long as it can be demonstrated that results are not affected. BS EN 50193-2-2:2016EN 50193-2-2:20165 Addition 5
23、.1.1.101 Set Points The appliance shall be set to achieve minimum flow (f) as specified in Annex A for all efficiency tests. This can be increased if the appliance is unable to operate continuously and the flow rate used recorded. This flow rate is used for all individual draw offs within the prescr
24、ibed load pattern. 5.1.2 Static efficiency Addition The loss adjustment for semiconductor power switches of open outlet electronic instantaneous water heaters is not applicable for this type of appliance. 5.1.3 Start up losses Replacement The start up loss istartQ is the total energy in kWh that is
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN50193222016ENELECTRICINSTANTANEOUSWATERHEATERSPART22PERFORMANCEREQUIREMENTSSINGLEPOINTOFUSEELECTRICINSTANTANEOUSSHOWERSEFFICIENCYPDF

链接地址:http://www.mydoc123.com/p-716798.html