EN 50083-8-2013 en Cable networks for television signals sound signals and interactive services - Part 8 Electromagnetic compatibility for networks.pdf
《EN 50083-8-2013 en Cable networks for television signals sound signals and interactive services - Part 8 Electromagnetic compatibility for networks.pdf》由会员分享,可在线阅读,更多相关《EN 50083-8-2013 en Cable networks for television signals sound signals and interactive services - Part 8 Electromagnetic compatibility for networks.pdf(38页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationBS EN 50083-8:2013Cable networks for televisionsignals, sound signals andinteractive services -Part 8: Electromagnetic compatibility fornetworksBS EN 50083-8:2013 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 50083-8:2013.It supersedes
2、 BS EN 50083-8:2002+A11:2008 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee EPL/100/4, Cable distribution equipment and systems.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not p
3、urport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2014. Published by BSI StandardsLimited 2014ISBN 978 0 580 78430 9ICS 33.060.40; 33.100.01Compliance with a British Standard cannot confer immunity fromleg
4、al obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 January 2014.Amendments issued since publicationDate Text affectedBS EN 50083-8:2013EUROPEAN STANDARD EN 50083-8 NORME EUROPENNE EUROPISCHE NORM December 2013 CENELEC European C
5、ommittee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide
6、for CENELEC members. Ref. No. EN 50083-8:2013 E ICS 33.060.40; 33.100.01 Supersedes EN 50083-8:2002 + A11:2008 English version Cable networks for television signals, sound signals and interactive services - Part 8: Electromagnetic compatibility for networks Rseaux de distribution par cbles pour sign
7、aux de tlvision, signaux de radiodiffusion sonore et services interactifs - Partie 8: Compatibilit lectromagntique des rseaux Kabelnetze fr Fernsehsignale, Tonsignale und interaktive Dienste - Teil 8: Elektromagnetische Vertrglichkeit von Kabelnetzen This European Standard was approved by CENELEC on
8、 2013-11-11. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may
9、 be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and no
10、tified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany
11、, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 50083-8:2013EN 50083-8:2013 2 Contents Page Foreword . 4 1 Scope 5 1.1 General .
12、5 1.2 Specific scope of EN 50083-8 . 5 2 Normative references 6 3 Terms, definitions, symbols and abbreviations . 6 3.1 Terms and definitions . 6 3.2 Symbols 9 3.3 Abbreviations . 9 4 Methods of measurement . 10 4.1 Basic principles . 10 4.2 Radiation from cable networks 10 4.2.1 General . 10 4.2.2
13、Field strength method . 11 4.2.3 Subcarrier measurement procedure . 12 4.2.4 GPS based leakage detection system . 13 4.3 Immunity of cable networks . 13 4.3.1 General . 13 4.3.2 Measurement procedure for interference caused by high-power local transmitter . 13 5 Performance requirements . 14 5.1 Gen
14、eral conditions 14 5.2 Radiation from cable networks and other sources 14 5.2.1 General . 14 5.2.2 Measurement of the total radiation 14 5.2.3 Measurement of narrowband radiation . 15 5.3 Immunity of cable networks . 16 Annex A (informative) A-deviations 18 A.1 United Kingdom . 18 A.1.1 Regulation 1
15、8 A.1.2 Principle . 18 A.1.3 Equipment 18 A.1.4 Measurement frequencies 18 A.1.5 Procedure . 19 A.1.6 Expression of results 19 A.1.7 Permitted limits 20 A.1.8 Interpretation . 20 A.1.9 Bibliography of A.1 22 A.2 United Kingdom . 22 A.2.1 Regulation 22 A.2.2 Principle . 22 A.2.3 Equipment 22 A.2.4 Me
16、asurement frequencies 22 A.2.5 Procedure . 23 A.2.6 Permitted limits 23 A.2.7 Interpretation . 24 A.2.8 Bibliography of A.2 24 A.3 Finland 25 A.4 Germany . 25 BS EN 50083-8:2013 3 EN 50083-8:2013 Annex B (informative) Frequency ranges of typical safety of life services 28 Annex C (informative) Inter
17、dependence between the maximum allowable field strength and the minimum signal level at system outlet 29 Annex D (informative) Measurements in other distances than the standard distance of 3 m 31 D.1 Measurement at a reduced distance below 3 m . 31 D.2 Measurement at measurement distances above 3 m
18、31 Annex E (informative) GPS based leakage detection system for cable networks . 32 E.1 General . 32 E.2 Automated data collection by driving through the HFC network . 32 E.3 Tagging of the signal 32 E.4 Post processing the collected data and visualisation of leakages 32 E.5 On site location of the
19、leak . 32 Bibliography 33 Figure A.1 Arrangement of test equipment for the measurement of radiation from complete systems 20 Table 1 Limits of total radiation . 15 Table 2 Narrowband radiation limits . 15 Table 3 Maximum expected field strength 16 Table 4 Required carrier-to-interference ratio 17 Ta
20、ble A.1 Radiation from complete systems: maximum permitted field strengths . 21 Table A.2 Distance correction factor . 22 Table A.3 Radiation from complete systems: maximum permitted field strengths . 24 Table A.4 Distance correction factor . 24 Table A.5 Protection of particular frequency ranges ac
21、cording to 3 of the Order 25 Table A.6 Field strength limit values at 3 m distance from line-bound telecommunications facilities and networks 27 Table B.1 Frequency ranges of typical safety of life services 28 BS EN 50083-8:2013EN 50083-8:2013 4 Foreword This document (EN 50083-8:2013) has been prep
22、ared by CLC/TC 209 “Cable networks for television signals, sound signals and interactive services“. The following dates are fixed: latest date by which this document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2014-11-08 latest dat
23、e by which the national standards conflicting with this document have to be withdrawn (dow) 2016-11-08 This document supersedes EN 50083-8:2002 + A11:2008. EN 50083-8:2013 includes the following significant technical changes with respect to EN 50083-8:2002 and EN 50083-8/A11:2008. EN 50083-8 with it
24、s methods of measurement and EMC performance requirements is explicitly dedicated to “under operating conditions (in situ)” to ensure the ongoing EMC integrity of cable networks. The harmonized standard EN 50529-2 is dedicated for the provision of presumption of conformance to the EMC Directive. The
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN5008382013ENCABLENETWORKSFORTELEVISIONSIGNALSSOUNDSIGNALSANDINTERACTIVESERVICESPART8ELECTROMAGNETICCOMPATIBILITYFORNETWORKSPDF

链接地址:http://www.mydoc123.com/p-716628.html