EN 16714-2-2016 en Non-destructive testing - Thermographic testing - Part 2 Equipment《无损检验-温度记录试验-第2部分 设备》.pdf
《EN 16714-2-2016 en Non-destructive testing - Thermographic testing - Part 2 Equipment《无损检验-温度记录试验-第2部分 设备》.pdf》由会员分享,可在线阅读,更多相关《EN 16714-2-2016 en Non-destructive testing - Thermographic testing - Part 2 Equipment《无损检验-温度记录试验-第2部分 设备》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN 16714-2:2016Non-destructive testing Thermographic testingPart 2: EquipmentBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS EN 16714-2:2016 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 16714-2:2016. The UK participation
2、 in its preparation was entrusted to TechnicalCommittee WEE/46, Non-destructive testing.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for
3、 its correct application. The British Standards Institution 2016.Published by BSI Standards Limited 2016ISBN 978 0 580 86967 9 ICS 19.100 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy a
4、nd Strategy Committee on 31 August 2016.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dBS EN 16714-2:2016EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 16714-2 August 2016 ICS 19.100 English Version Non-destructive testing - Thermographic testing - Part 2: Equipment
5、Essais non destructifs - Analyses thermographiques - Partie 2: Equipement Zerstrungsfreie Prfung - Thermografische Prfung - Teil 2: Gerte This European Standard was approved by CEN on 25 June 2016. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditio
6、ns for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in
7、 three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standard
8、s bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Sloven
9、ia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CEN All rights of exploitation in any form and by any means reserved w
10、orldwide for CEN national Members. Ref. No. EN 16714-2:2016 EBS EN 16714-2:2016EN 16714-2:2016 (E) 2 Contents Page European foreword . 4 1 Scope 5 2 Normative references 5 3 Terms and definitions . 5 4 Equipment . 5 4.1 Selection of infrared camera . 5 4.2 Classification of IR cameras . 5 4.2.1 Gene
11、ral 5 4.2.2 Temperature range 6 4.2.3 Thermal resolution. 6 4.2.4 Spatial resolution and lenses 7 4.2.5 Frame rate and temporal resolution 7 4.2.6 Operating temperature range 7 4.2.7 Storage temperature range . 7 4.2.8 Spectral filter 7 4.3 Accessories 8 4.3.1 Interchangeable lenses . 8 4.3.2 IR mir
12、rors 8 4.3.3 IR protective windows . 8 4.3.4 IR camera protective housing . 8 4.3.5 Examples of excitation sources for active thermography 8 5 Function check and traceability . 9 5.1 General remarks 9 5.2 Checks by the user 9 5.3 Additional checks by the camera supplier . 9 5.4 Frequency of function
13、 checks . 9 Annex A (normative) Parameters and measuring methods for characterizing IR cameras . 10 A.1 Instantaneous field of view (IFOV) 10 Figure A.1 Instantaneous field of view (IFOV) 11 A.2 Field of view (FOV). 12 Figure A.2 Field of view (FOV) 12 A.3 Slit response function (SRF) . 13 Figure A.
14、3 Principle for the determination of the slit response function (SRF) . 14 Figure A.4 Slit response function (SRF). 15 A.4 Hole response function (HRF) . 15 A.5 Noise Equivalent Temperature Difference (NETD) . 16 A.6 Minimum resolvable temperature difference (MRTD) 16 Annex B (informative) Examples
15、for accessories . 17 BS EN 16714-2:2016EN 16714-2:2016 (E) 3 B.1 Thermometer . 17 B.2 Moisture measuring devices . 17 B.3 Anemometer . 17 B.4 Clamp-on ammeter . 17 B.5 Cameras in the visible range 17 B.6 Endoscope . 17 Bibliography . 18 BS EN 16714-2:2016EN 16714-2:2016 (E) 4 European foreword This
16、document (EN 16714-2:2016) has been prepared by Technical Committee CEN/TC 138 “Non-destructive testing”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by
17、 February 2017, and conflicting national standards shall be withdrawn at the latest by February 2017. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
18、 EN 16714, Non-destructive testing Infrared thermographic testing consists of the following parts: Part 1: General principles Part 2: Equipment Part 3: Terms and definitions According to the CEN-CENELEC Internal Regulations, the national standards organisations of the following countries are bound t
19、o implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, R
20、omania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 16714-2:2016EN 16714-2:2016 (E) 5 1 Scope This European Standard describes properties and requirements of infrared cameras used for thermographic testing for non-destructive testing. This document gives also
21、 examples of excitation sources, the properties and requirements are described in application standards for active thermography. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated refer
22、ences, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 16714-3, Non-destructive testing Infrared thermographic testing Part 3: Terms and definitions 3 Terms and definitions For the purposes of this document,
23、 the terms and definitions given in EN 16714-3 apply. 4 Equipment 4.1 Selection of infrared camera The infrared camera (IR camera) has to be selected according to the application and the temperature of the inspected object. IR camera relevant parameters are: spectral sensitivity; temperature range;
24、thermal resolution; spatial resolution; frame rate; temporal resolution. These parameters shall be provided by the manufacturer. 4.2 Classification of IR cameras 4.2.1 General IR cameras are classified according to detector arrangement and working principle. The classification according to the detec
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN1671422016ENNONDESTRUCTIVETESTINGTHERMOGRAPHICTESTINGPART2EQUIPMENT 无损 检验 温度 记录 试验 部分 设备 PDF

链接地址:http://www.mydoc123.com/p-716105.html