EN 16016-2-2011 en Non destructive testing - Radiation methods - Computed tomography - Part 2 Principle equipment and samples《非破坏性试验 辐射方法 计算机断层扫描 第2部分 原理 设备和样品》.pdf
《EN 16016-2-2011 en Non destructive testing - Radiation methods - Computed tomography - Part 2 Principle equipment and samples《非破坏性试验 辐射方法 计算机断层扫描 第2部分 原理 设备和样品》.pdf》由会员分享,可在线阅读,更多相关《EN 16016-2-2011 en Non destructive testing - Radiation methods - Computed tomography - Part 2 Principle equipment and samples《非破坏性试验 辐射方法 计算机断层扫描 第2部分 原理 设备和样品》.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 16016-2:2011Non destructive testing Radiation methods Computed tomographyPart 2: Principle, equipment and samplesBS EN 16016-2:2011 BRITISH STANDARDNational forewordThis Br
2、itish Standard is the UK implementation of EN 16016-2:2011.The UK participation in its preparation was entrusted to TechnicalCommittee WEE/46, Non-destructive testing.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to
3、 include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. BSI 2011ISBN 978 0 580 62739 2ICS 19.100Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy
4、 and Strategy Committee on 30 September 2011.Amendments issued since publicationDate Text affectedBS EN 16016-2:2011EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 16016-2 August 2011 ICS 19.100 English Version Non destructive testing - Radiation methods - Computed tomography - Part 2: Principl
5、e, equipment and samples Essais non destructifs - Mthodes par rayonnements - Tomographie numrise - Partie 2 : Principes, quipementset chantillons Zerstrungsfreie Prfung - Durchstrahlungsverfahren - Computertomographie - Teil 2: Grundlagen, Gerte und Proben This European Standard was approved by CEN
6、on 29 July 2011. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may
7、 be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified t
8、o the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Lux
9、embourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2011 CEN All ri
10、ghts of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 16016-2:2011: EBS EN 16016-2:2011EN 16016-2:2011 (E) 2 Contents Page Foreword 3Introduction .41 Scope 52 Normative references 53 Terms and definitions .54 General principles54.1 Basic principle
11、s .54.2 Advantages of CT 54.3 Limitations of CT64.4 Main CT process steps 64.4.1 Acquisition .64.4.2 Reconstruction .74.4.3 Visualisation and analysis 74.5 Artefacts in CT images 85 Equipment and apparatus .85.1 General 85.2 Radiation sources 95.3 Detectors . 105.4 Manipulation 105.5 Acquisition, re
12、construction, visualisation and storage system 106 CT system stability . 116.1 General . 116.2 X-Ray Stability . 116.3 Manipulator stability . 117 Geometric alignment 128 Sample considerations 128.1 Size and shape of sample 128.2 Materials (including table voltage / thickness of penetration) . 12Ann
13、ex A (informative) CT system components 15A.1 Radiation sources . 15A.1.1 Open Tube X-ray sets . 15A.1.2 Sealed Tube X-ray Sets 16A.1.3 Linear Accelerators 16A.1.4 X-ray target assemblies . 17A.2 Detectors . 18A.2.1 Ionisation detectors 18A.2.2 Scintillation detectors 18A.2.3 Semiconductor detectors
14、 19A.3 Manipulation 19A.4 Acquisition, reconstruction, visualisation and storage system 19A.4.1 Acquisition system . 19A.4.2 Reconstruction system 20A.4.3 Visualisation system 20A.4.4 Storage system . 20Bibliography . 21BS EN 16016-2:2011EN 16016-2:2011 (E) 3 Foreword This document (EN 16016-2:2011)
15、 has been prepared by Technical Committee CEN/TC 138 “Non-destructive testing”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2012, and confli
16、cting national standards shall be withdrawn at the latest by February 2012. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. EN 16016 c
17、onsists of the following parts: Non destructive testing Radiation methods Computed tomography Part 1: Terminology; Non destructive testing Radiation methods Computed tomography Part 2: Principle, equipment and samples; Non destructive testing Radiation methods Computed tomography Part 3: Operation a
18、nd interpretation; Non destructive testing Radiation methods Computed tomography Part 4: Qualification. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croati
19、a, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 16016-2:2011EN 16016-2:2
20、011 (E) 4 Introduction This document gives guidelines for the general principles of X-ray computed tomography (CT) applicable to industrial imaging (in the context of this standard, industrial means non-medical applications); it also gives a consistent set of CT performance parameter definitions, in
21、cluding how these performance parameters relate to CT system specifications. This document deals with computed axial tomography and excludes other types of tomography such as translational tomography and tomosynthesis. BS EN 16016-2:2011EN 16016-2:2011 (E) 5 1 Scope This European Standard specifies
22、the general principles of computed tomography (CT), the equipment used and basic considerations of sample, materials and geometry. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. F
23、or undated references, the latest edition of the referenced document (including any amendments) applies. EN 473, Non-destructive testing Qualification and certification of NDT personnel General principles EN 16016-1:2011, Non destructive testing Radiation method Computed tomography Part 1: Terminolo
24、gy EN 16016-3:2011, Non destructive testing Radiation methods Part 3: Operation and interpretation EN 16016-4:2011, Non destructive testing Radiation methods Part 4: Qualification 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 16016-1:2011 apply. 4 G
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN1601622011ENNONDESTRUCTIVETESTINGRADIATIONMETHODSCOMPUTEDTOMOGRAPHYPART2PRINCIPLEEQUIPMENTANDSAMPLES

链接地址:http://www.mydoc123.com/p-715538.html