EN 15882-2-2015 en Extended application of results from fire resistance tests for service installations - Part 2 Fire dampers《用于服务安装的防火性测试结果的拓展性应用 第2部分 防火挡板》.pdf
《EN 15882-2-2015 en Extended application of results from fire resistance tests for service installations - Part 2 Fire dampers《用于服务安装的防火性测试结果的拓展性应用 第2部分 防火挡板》.pdf》由会员分享,可在线阅读,更多相关《EN 15882-2-2015 en Extended application of results from fire resistance tests for service installations - Part 2 Fire dampers《用于服务安装的防火性测试结果的拓展性应用 第2部分 防火挡板》.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationBS EN 15882-2:2015Extended application of resultsfrom fire resistance tests forservice installationsPart 2: Fire dampersBS EN 15882-2:2015 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 15882-2:2015.The UK participation in its preparati
2、on was entrusted to TechnicalCommittee FSH/22/-/4, Fire resistance tests for dampers, seals andsmoke extraction.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Use
3、rs are responsible for its correctapplication. The British Standards Institution 2015. Published by BSI StandardsLimited 2015ISBN 978 0 580 86317 2ICS 13.220.99Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of t
4、heStandards Policy and Strategy Committee on 30 April 2015.Amendments issued since publicationDate Text affectedBS EN 15882-2:2015EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 15882-2 April 2015 ICS 13.220.99 English Version Extended application of results from fire resistance tests for servi
5、ce installations - Part 2: Fire dampers Application tendue des rsultats des essais de rsistance au feu des installations de service - Partie 2 : Clapets rsistant au feu Erweiterter Anwendungsbereich der Ergebnisse aus Feuerwiderstandsprfungen fr Installationen - Teil 2: Brandschutzklappen This Europ
6、ean Standard was approved by CEN on 11 January 2015. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references co
7、ncerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member
8、into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France
9、, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMI
10、TEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15882-2:2015 EBS EN 15882-2:2015EN 15882-2:2015 (E) 2 Contents Page Foreword 3 Introduction .4 1 S
11、cope 5 2 Normative references 5 3 Terms and definitions .6 4 Determination of worst case .6 5 Conditions and application rules .6 5.1 Change of fixing damper to supporting construction .6 5.2 Multiple damper assemblies .7 5.2.1 E Classification only 7 5.2.2 EI, E-S, EI-S Classifications 8 5.3 Altern
12、ative penetration seals 8 6 Influence of parameters and factors on fire damper performance .9 7 Critical parameters and factors 9 7.1 General 9 7.2 Common operational parameters and factors 9 7.3 Constructional parameters .9 7.4 Parameters of components of damper . 10 7.5 Installing parameters 11 8
13、Methodology 12 9 Report of the extended application analysis . 20 Bibliography . 22 BS EN 15882-2:2015EN 15882-2:2015 (E) 3 Foreword This document (EN 15882-2:2015) has been prepared by Technical Committee CEN/TC 127 “Fire safety in buildings”, the secretariat of which is held by BSI. This European
14、Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2015 and conflicting national standards shall be withdrawn at the latest by October 2015. Attention is drawn to the possibility that some of the elements
15、of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association. EN 15882, Extended ap
16、plication of results from fire resistance tests for service installations consists of the following parts: Part 1: Ducts Part 2: Fire dampers Part 3: Penetration seals Part 4: Linear joint seals According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following
17、countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway
18、, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 15882-2:2015EN 15882-2:2015 (E) 4 Introduction It should be noted that fire-resisting dampers are special products that are exposed to different conditions to other elements of construct
19、ion; in particular they are subjected to significantly different pressure regimes. Also, integrity is evaluated by leakage measurements. Consequently, this European Standard may adopt a different approach to other extended field of application standards, with more emphasis on testing. BS EN 15882-2:
20、2015EN 15882-2:2015 (E) 5 1 Scope This European Standard provides guidance and rules to notified bodies (for fire dampers) to allow them to produce/validate an extended field of application report for fire dampers. This standard identifies the parameters that affect the fire resistance of dampers. I
21、t also identifies the factors that need to be considered when deciding whether, or by how much, the parameter can be extended when contemplating the fire resistance performance of an untested, or untestable variation in the construction. This European Standard explains the principles behind how a co
22、nclusion on the influence of specific parameters/constructional details relating to the relevant criteria (E,I,S) can be achieved. This European Standard does not cover dampers used for smoke control. This European Standard only applies to extended fields of application based on tests successfully u
23、ndertaken to EN 1366-2. Only test reports that have a total test time where the criteria are fulfilled that is in excess of the required classification period by a margin of either 10 % or 12 min, whichever is the least, are to be considered. Each classification (E,I,S) is to be considered individua
24、lly consequently E (134 min achieved) may be extended, but EI (61 min achieved) may not be extended for a classification of EI60. Additionally, leakage determined during such tests is to be at least 10 % below the leakage limits for E, or for E-S, dependent on classification achieved, given in EN 13
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN1588222015ENEXTENDEDAPPLICATIONOFRESULTSFROMFIRERESISTANCETESTSFORSERVICEINSTALLATIONSPART2FIREDAMPERS

链接地址:http://www.mydoc123.com/p-715430.html