EN 15802-2009 en Conservation of cultural property - Test methods - Determination of static contact angle《文化遗产保护的试验方法 静态接触角的测定》.pdf
《EN 15802-2009 en Conservation of cultural property - Test methods - Determination of static contact angle《文化遗产保护的试验方法 静态接触角的测定》.pdf》由会员分享,可在线阅读,更多相关《EN 15802-2009 en Conservation of cultural property - Test methods - Determination of static contact angle《文化遗产保护的试验方法 静态接触角的测定》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN 15802:2009ICS 97.195NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDConservation ofcultural property Test methods Determination of staticcontact angleThis British Standardwas published under theauthority of the StandardsPolicy and StrategyCommittee on 31 J
2、anuary2010 BSI 2010ISBN 978 0 580 61876 5Amendments/corrigenda issued since publicationDate CommentsBS EN 15802:2009National forewordThis British Standard is the UK implementation of EN 15802:2009.The UK participation in its preparation was entrusted to TechnicalCommittee B/560, Conservation of tang
3、ible cultural heritage.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with a British Standard cannot
4、confer immunityfrom legal obligations.BS EN 15802:2009EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 15802 December 2009 ICS 97.195 English Version Conservation of cultural property - Test methods - Determination of static contact angle Conservation des biens culturels - Mthodes dessai - Dterm
5、ination de langle de contact statique Erhaltung des kulturellen Erbes - Prfverfahren - Messung des statischen Kontaktwinkels This European Standard was approved by CEN on 7 November 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giv
6、ing this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official ve
7、rsions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgi
8、um, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR
9、STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15802:2009: EBS EN 15802:2009EN 15802:2009 (E)
10、2 Contents Page Foreword 3Introduction .41 Scope 52 Normative references 53 Terms and definitions .54 Principle 56 Test equipment 67 Preparation of test specimens .77.1 Number and dimensions of test specimens .77.2 Pre-conditioning of test specimens .78 Test procedure .79 Expression of results 89.1
11、Calculation of the static contact angle 810 Test report 8Annex A (informative) Physical meaning of the static contact angle . 10Bibliography . 11BS EN 15802:2009EN 15802:2009 (E) 3 Foreword This document (EN 15802:2009) has been prepared by Technical Committee CEN/TC 346 “Conservation of cultural pr
12、operty”, the secretariat of which is held by UNI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by June 2010 and conflicting national standards shall be withdrawn at the latest by June 2010. Attent
13、ion is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of t
14、he following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovak
15、ia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. BS EN 15802:2009EN 15802:2009 (E) 4 Introduction This test method can be applied if it does not change the value of the cultural property and follows relevant ethical codes of conservation practice. BS EN 15802:2009EN 15802:2009 (E) 5 1 Sc
16、ope This European Standard specifies a method for the measurement of the static contact angle of a water drop on porous inorganic materials used for and constituting cultural property. The method may be applied to porous inorganic materials either untreated or subjected to any treatment or ageing. 2
17、 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. prEN 15898:2009, Conservati
18、on of cultural property Main general terms and definitions concerning conservation of cultural property 3 Terms and definitions For the purposes of this document, the terms and definitions given in prEN 15898:2009 and the following apply. 3.1 porous inorganic materials materials including natural st
19、ones, e.g. sandstone, limestone, marble, as well as artificial materials, such as mortar, plaster, brick and others 3.2 static contact angle angle , in degrees, formed by the surface of the specimen and the tangent to the water drop at the contact point, as shown in Figure 1 Key d diameter of the co
20、ntact surface, in mm h height, in mm static contact angle, in degrees Figure 1 Static contact angle at time t 4 Principle Determination of the static contact angle between a water drop and the test surface of the specimen. BS EN 15802:2009EN 15802:2009 (E) 6 5 Symbols and abbreviations For the purpo
21、ses of this document, the following symbols and abbreviations apply: d diameter of the contact surface, in mm h height, in mm static contact angle, in degrees 6 Test equipment 6.1 Test equipment for the measurement of static contact angle consists of: i) an illumination source (1) that will not affe
22、ct the temperature of the drop/specimen system, ii) a flat sample holder (2), iii) a drop deposition system, usually consisting of a graduated micro-pipette (3), with a flat head needle, positioned above and perpendicular to the specimen surface and able to deliver reproducible drops, iv) an optical
23、 system (4) that projects the image of the deposited water drop onto a screen (5) on which the height of the water drop and the diameter of the contact surface can be marked with a ruler (6). This part of the instrument can consist of a camera (4) able to record the image on a screen (5) where the p
24、arameters can be measured manually or automatically. The measurement principle of most commercial instruments available on the market is shown in Figure 2. Key 1 illumination source 2 sample holder 3 graduated micro-pipette 4 optical system 5 screen 6 ruler Figure 2 Schematic sketch of the measureme
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN158022009ENCONSERVATIONOFCULTURALPROPERTYTESTMETHODSDETERMINATIONOFSTATICCONTACTANGLE 文化遗产 保护 试验 方法

链接地址:http://www.mydoc123.com/p-715371.html