EN 15651-1-2012 1875 Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 1 Sealants for facade elements《建筑和行人专用区接缝处非结构化用密封剂 外观元件密封剂》.pdf
《EN 15651-1-2012 1875 Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 1 Sealants for facade elements《建筑和行人专用区接缝处非结构化用密封剂 外观元件密封剂》.pdf》由会员分享,可在线阅读,更多相关《EN 15651-1-2012 1875 Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 1 Sealants for facade elements《建筑和行人专用区接缝处非结构化用密封剂 外观元件密封剂》.pdf(30页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 15651-1:2012Sealants for non-structuraluse in joints in buildings andpedestrian walkwaysPart 1: Sealants for facade elementsCopyright European Committee for Standardization
2、 Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 15651-1:2012 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 15651-1:2012.It supersedes BS EN 15651-1:2010 which is withdrawn.The UK p
3、articipation in its preparation was entrusted to TechnicalCommittee B/547, Sealants for building and construction.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. U
4、sers are responsible for its correctapplication. The British Standards Institution 2012. Published by BSI StandardsLimited 2012ISBN 978 0 580 76842 2ICS 91.100.50Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of
5、 theStandards Policy and Strategy Committee on 30 September 2012.Amendments issued since publicationDate Text affectedCopyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 15651-
6、1:2012EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 15651-1 September 2012 ICS 91.100.50 English Version Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 1: Sealants for facade elements Mastics pour joints pour des usages non structuraux dans les construct
7、ions immobilires et pour chemins pitonniers - Partie 1 : Mastics pour lments de faade Fugendichtstoffe fr nicht tragende Anwendungen in Gebuden und Fugngerwegen - Teil 1: Fugendichtstoffe fr Fassadenelemente This European Standard was approved by CEN on 10 August 2012. CEN members are bound to compl
8、y with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
9、Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the sam
10、e status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg,
11、 Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2012 CEN All ri
12、ghts of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15651-1:2012: ESupersedes EN 15651-1:2010Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without lic
13、ense from IHS-,-,-BS EN 15651-1:2012EN 15651-1:2012 (E) 2 Contents Page Foreword 31 Scope 42 Normative references 43 Terms and definitions .54 Requirements .54.1 Identification requirements and test methods 54.1.1 Short description of the sealant .54.1.2 Thermogravimetric test .54.1.3 Specific gravi
14、ty 64.1.4 Indentation hardness (Shore hardness) 64.2 Conditioning, test procedure and substrates .64.3 Performance requirements and test methods for non-structural sealants for facade elements .74.3.1 General 74.3.2 Sealants for facade elements used in cold climates 84.3.3 Resistance to flow .94.4 P
15、erformance requirements for non-structural sealants for facade elements for interior application only 94.5 Release of dangerous substances .94.6 Reaction to fire .94.6.1 General 94.6.2 Mounting and fixing conditions for test samples .95 Durability . 126 Sampling 127 Evaluation of conformity 127.1 Ge
16、neral . 127.2 Initial type testing . 127.3 Factory production control 128 Marking and labelling . 12Annex A (informative) Example on the frequency of tests for factory production control 13Annex ZA (informative) Clause of this European Standard addressing the provisions of EU Construction Products D
17、irective . 14ZA.1 Scope and relevant characteristics 14ZA.2 Procedure for attestation of conformity of non-structural sealants for external and/or internal side of facade elements . 16ZA.2.1 Systems of attestation of conformity . 16ZA.2.2 EC certificate of conformity and EC declaration of conformity
18、 . 19ZA.3 CE marking and labelling . 23ZA.3.1 General . 23ZA.3.2 CE marking on the packaging . 23ZA.3.3 CE marking in the accompanying commercial documents . 24Bibliography . 26Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or net
19、working permitted without license from IHS-,-,-BS EN 15651-1:2012EN 15651-1:2012 (E) 3 Foreword This document (EN 15651-1:2012) has been prepared by Technical Committee CEN/TC 349 “Sealants for joints in building construction”, the secretariat of which is held by AFNOR. This European Standard shall
20、be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by March 2013, and conflicting national standards shall be withdrawn at the latest by June 2014. Attention is drawn to the possibility that some of the elements of this document ma
21、y be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 15651-1:2010. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association
22、, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. This document is one of the product European Standards within the framework series of EN 15651 on Sealants for non-structural use in
23、joints in buildings and pedestrian walkways, as follows: Part 1: Sealants for facade elements (this document), Part 2: Sealants for glazing, Part 3: Sealants for sanitary joints, Part 4: Sealants for pedestrian walkways, Part 5: Evaluation of conformity and marking. The following significant technic
24、al changes have been implemented in this new edition: an Annex ZA has been added; the clause on reaction to fire was improved. According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Be
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN15651120121875SEALANTSFORNONSTRUCTURALUSEINJOINTSINBUILDINGSANDPEDESTRIANWALKWAYSPART1SEALANTSFORFACADEELEMENTS

链接地址:http://www.mydoc123.com/p-715257.html