EN 15097-2006 en Irrigation techniques - Localised irrigation - Hydraulic evaluation《灌溉技术 局部灌溉 测定水压》.pdf
《EN 15097-2006 en Irrigation techniques - Localised irrigation - Hydraulic evaluation《灌溉技术 局部灌溉 测定水压》.pdf》由会员分享,可在线阅读,更多相关《EN 15097-2006 en Irrigation techniques - Localised irrigation - Hydraulic evaluation《灌溉技术 局部灌溉 测定水压》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 15097:2006Irrigation techniques Localised irrigation Hydraulic evaluationThe European Standard EN 15097:2006 has the status of a British StandardICS 65.060.35g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36
2、g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 15097:2006This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 November 2006 BSI 2006ISBN 0 580 49758 5National forewordThis British Standard was published by
3、 BSI. It is the UK implementation of EN 15097:2006.The UK participation in its preparation was entrusted to Technical Committee AGE/30, Irrigation and drainage equipment.A list of organizations represented on AGE/30 can be obtained on request to its secretary.This publication does not purport to inc
4、lude all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 15097November
5、 2006ICS 65.060.35English VersionIrrigation techniques - Localised irrigation - Hydraulic evaluationTechniques dirrigation - Irrigation localise - EvaluationhydrauliqueBewsserungsverfahren - rtliche Bewsserung -Hydraulische FestlegungenThis European Standard was approved by CEN on 23 September 2006.
6、CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on app
7、lication to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has t
8、he same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,
9、Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2006 CEN All rights of exploitation in any form and by any means reservedworldwid
10、e for CEN national Members.Ref. No. EN 15097:2006: EEN 15097:2006 (E) 2 Contents Page Foreword3 1 Scope 4 2 Normative references 4 3 Terms and definitions .4 4 Basic data for the evaluation4 4.1 General data of the farm .4 4.2 Localised irrigation system data5 4.3 Farm-unit features .5 5 Data to be
11、collected for the evaluation5 6 Test procedure.6 7 Equipment needed.8 8 Blank data forms8 Bibliography 16 EN 15097:2006 (E) 3 Foreword This document (EN 15097:2006) has been prepared by Technical Committee CEN/TC 334 “Irrigation Techniques”, the secretariat of which is held by AENOR. This European S
12、tandard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2007, and conflicting national standards shall be withdrawn at the latest by May 2007. According to the CEN/CENELEC Internal Regulations, the national standard
13、s organizations of the following countries are bound to implement this European Standard : Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Roma
14、nia, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 15097:2006 (E) 4 1 Scope The purpose of this Standard is to describe a localised irrigation hydraulic system and to specify a method to determine the uniformity in water distribution for each installation to be evaluated in t
15、he field. This document applies to localised irrigation systems. It does not cover management practices. This paper defines the methodology to be applied in the farm localised irrigation system evaluation. 2 Normative references The following referenced documents are indispensable for the applicatio
16、n of this European Standard. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 13635:2001, Irrigation techniques Localised irrigation systems Terminology and data to be supplied by the ma
17、nufacturer 3 Terms and definitions For the purposes of this European Standard, the terms and definitions given in EN 13635:2001 and the following apply. 3.1 emission uniformity coefficient expressed as a percent relating the minimum rate of discharge to the average rate of discharge per plant 3.2 fl
18、ow rate uniformity coefficient expressed as a percent relating to the minimum flow rate of an emitting device to the average flow rate of the emitting device 4 Basic data for the evaluation 4.1 General data of the farm The following data should be known before the evaluation: a) situation plan; b) t
19、opographical map; c) owner; d) farm name; e) location; f) date of evaluation. EN 15097:2006 (E) 5 4.2 Localised irrigation system data The following data should be known before the evaluation: a) manufacturer or installer; b) age of installation; c) water supply; d) pipe installation: diameter and m
20、aterial; e) emitters: type and point spacing; f) pump station; g) filtration system; h) fertilization equipment; i) flow-rates and pressures control systems; j) automatic control systems; k) design layout. 4.3 Farm-unit features The following data should be known before the evaluation: a) geometric
21、characteristics; b) topographic characteristics: slope. 5 Data to be collected for the evaluation The following data should be known before the evaluation: a) water pressure at the control head, filters and pressure regulators; b) water pressure at the inlet of the irrigation block, sub-mains and la
22、terals; c) emitters flow-rate; d) wetted area; e) head-losses in the tested laterals; f) clogging of the emitters; g) check irrigation control head, filters, other pieces and automatic control systems. EN 15097:2006 (E) 6 6 Test procedure The test shall be carried out under usual working conditions.
23、 The procedure shall be the following: Choose a subunit (SR) that is typical for conditions over the whole irrigated area and, if it is possible, representative of the installation. Select another subunit if the topographical or hydraulic conditions vary greatly. This subunit should represent the ha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN150972006ENIRRIGATIONTECHNIQUESLOCALISEDIRRIGATIONHYDRAULICEVALUATION 灌溉 技术 局部 测定 水压 PDF

链接地址:http://www.mydoc123.com/p-714773.html