《EN 14989-2-2007 en Chimneys - Requirements and test methods for metal chimneys and material independent air supply ducts for roomsealed heating applications - Part 2 Flue and air s.pdf》由会员分享,可在线阅读,更多相关《EN 14989-2-2007 en Chimneys - Requirements and test methods for metal chimneys and material independent air supply ducts for roomsealed heating applications - Part 2 Flue and air s.pdf(82页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN14989-2:2007ICS 91.060.40; 91.140.30NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDChimneys Requirements andtest methods for metalchimneys and materialindependent air supplyducts for roomsealedheating applicationsPart 2: Flue and air supply ducts forroom s
2、ealed appliancesThis British Standardwas published under theauthority of the StandardsPolicy and StrategyCommittee on 31 August2008 BSI 2008ISBN 978 0 580 54633 4Amendments/corrigenda issued since publicationDate CommentsBS EN 14989-2:2007National forewordThis British Standard is the UK implementati
3、on of EN 14989-2:2007.The UK participation in its preparation was entrusted to TechnicalCommittee B/506, Chimneys.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. U
4、sers are responsible for its correct application.Compliance with a British Standard cannot confer immunityfrom legal obligations.BS EN 14989-2:2007EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 14989-2December 2007ICS 91.060.40; 91.140.30English VersionChimneys - Requirements and test methods for
5、 metal chimneysand material independent air supply ducts for roomsealedheating applications - Part 2: Flue and air supply ducts for roomsealed appliancesConduits de fume - Exigences et mthodes dessai pourconduits de fume mtalliques et conduits dalimentationen air pour tous matriaux pour des appareil
6、s de chauffagetanches - Partie 2: Conduits de fume et dalimentation enair pour appareils tanchesAbgasanlagen - Anforderungen und Prfverfahren frMetall-Abgasanlagen und materialunabhngigeLuftleitungen fr raumluftunabhngige Anlagen - Teil 2:Abgas- und Luftleitungen fr raumluftunabhngigeFeuerstttenThis
7、 European Standard was approved by CEN on 10 November 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical referenc
8、es concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into i
9、ts own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lith
10、uania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2007 CEN
11、 All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14989-2:2007: EBS EN 14989-2:2007EN 14989-2:2007 (E) 2 Contents Page Foreword5 Introduction .6 1 Scope 7 2 Normative references 7 3 Terms and definitions .7 4 Symbols and abbreviations 8 5
12、 Manufacturers declaration for type testing11 6 Dimensions and tolerances 11 7 Performance requirements .11 7.1 General11 7.2 Mechanical resistance and stability.11 7.2.1 Compressive strength.11 7.2.2 Tensile strength .12 7.2.3 Lateral strength12 7.3 Resistance to fire.12 7.3.1 Internal to external.
13、12 7.3.2 External to external12 7.4 Hygiene, health and environment 12 7.4.1 Gastightness of the flue duct .12 7.4.2 Gastightness of the air supply duct.13 7.5 Safety in use.13 7.5.1 Thermal performance 13 7.5.2 Thermal resistance 14 7.5.3 Rainwater ingress14 7.5.4 Flow resistance of the flue and ai
14、r supply ducts and fittings.14 7.5.5 Water vapour diffusion resistance.15 7.5.6 Condensate penetration resistance.15 7.6 Materials .15 7.6.1 Flue ducts and other parts in contact with combustion products .15 7.6.2 Air supply duct and other parts not in contact with combustion products 16 7.6.3 Addit
15、ional information on plastics and elastomers.16 7.6.4 Freeze/thaw 16 8 Product information.16 8.1 Manufacturers instructions16 8.2 Minimum information to be included in the manufacturers instructions .16 8.3 Appliance adapter17 9 Marking .17 9.1 General17 9.2 Flue and air supply duct .17 9.3 Packagi
16、ng .18 9.4 Chimney plate 18 10 Designation 19 10.1 General19 10.2 Temperature classes and test temperature 19 10.3 Pressure class20 10.4 Condensate resistance class .20 BS EN 14989-2:2007EN 14989-2:2007 (E) 3 10.5 Corrosion resistance.20 10.5.1 Corrosion resistance.20 10.5.2 Flue duct material speci
17、fication.21 10.6 Resistance to fire Soot fire resistance, and distance to combustible material .21 11 Evaluation of conformity 21 11.1 General .21 11.2 Type testing .22 11.2.1 Initial type testing (ITT) .22 11.2.2 Further type testing.22 11.2.3 Sampling for type testing .22 11.3 Factory production c
18、ontrol (FPC)22 11.3.1 General .22 11.3.2 Equipment 24 11.3.3 Raw materials and components 24 11.3.4 Product testing and evaluation24 11.3.5 Non conforming products 24 12 Test methods .24 12.1 Mechanical resistance and stability 24 12.1.1 Compressive strength.24 12.1.2 Tensile strength.26 12.1.3 Late
19、ral strength .26 12.2 Hygiene, health and environment28 12.2.1 Gastightness28 12.3 Safety in use 29 12.3.1 Thermal performance29 12.3.2 Thermal resistance41 12.3.3 Rainwater ingress48 12.3.4 Flow resistance of the flue and air supply ducts .50 12.3.5 Vapour and condensate resistance test .53 12.3.6
20、Condensate resistance test56 12.4 Low temperature test 59 Annex A (informative) Preferred dimensions.60 A.1 General .60 A.2 Dimensions of the push-in spigots for a separate air/flue configuration60 A.3 Dimensions of the push-in spigots for a concentric air/flue configuration 62 Annex B (normative) C
21、oefficients of flow resistance .64 Annex C (normative) Choice of size for type test and sampling .67 Annex D (normative) Sampling for factory production control .68 D.1 Incoming material68 D.1.1 Sampling plans 68 D.1.2 Acceptable quality level (AQL).68 D.1.3 Normal, tightened or reduced inspection .
22、68 D.1.4 Single, double, multiple or sequential sampling68 D.1.5 Batch quantity68 D.1.6 The inspection level 68 D.2 In-process inspection .69 D.2.1 All dimensional aspects69 D.2.2 Joint leakage tests 69 D.2.3 Insulation weight checks69 D.2.4 Volume and density checks .69 D.2.5 Finished goods checks.
23、69 Annex E (normative) Factory production control70 E.1 Insulation material.70 E.2 Metals, including coatings70 E.3 Supports.70 E.4 Seals and sealants 70 BS EN 14989-2:2007EN 14989-2:2007 (E) 4 E.5 Manufacturing checks.71 E.5.1 Dimensions.71 E.5.2 Other checks 71 Annex ZA (informative) Clauses of th
24、is European Standard addressing the provisions of the EU Construction Products Directive72 ZA.1 Scope and relevant characteristics72 ZA.2 Procedure for attestation of conformity of metal liners, connecting flue pipes and fittings flue and material independent air supply ducts for room sealed applian
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN1498922007ENCHIMNEYSREQUIREMENTSANDTESTMETHODSFORMETALCHIMNEYSANDMATERIALINDEPENDENTAIRSUPPLYDUCTSFORROOMSEALEDHEATINGAPPLICATIONSPART2FLUEANDAIRSPDF

链接地址:http://www.mydoc123.com/p-714656.html