EN 14983-2007 en Explosion prevention and protection in underground mines - Equipment and protective systems for firedamp drainage《地下矿井中的防爆和保护 沼气排放设备和保护系统》.pdf
《EN 14983-2007 en Explosion prevention and protection in underground mines - Equipment and protective systems for firedamp drainage《地下矿井中的防爆和保护 沼气排放设备和保护系统》.pdf》由会员分享,可在线阅读,更多相关《EN 14983-2007 en Explosion prevention and protection in underground mines - Equipment and protective systems for firedamp drainage《地下矿井中的防爆和保护 沼气排放设备和保护系统》.pdf(34页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 14983:2007Explosion prevention and protection in underground mines Equipment and protective systems for firedamp drainageThe European Standard EN 14983:2007 has the status of a British StandardICS 13.230; 73.100.20g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g
2、3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 14983:2007This British Standard was published under the authority of the Standards Policy and Strategy Committee on 29 June 2007 BSI 2007ISBN 978 0 580 54456
3、9National forewordThis British Standard was published by BSI. It is the UK implementation of EN 14983:2007.The UK participation in its preparation was entrusted to Technical Committee FSH/23, Fire precautions in industrial and chemical plant.A list of organizations represented on this committee can
4、be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations. Amendments issued since publicationAmd.
5、 No. Date CommentsEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 14983March 2007ICS 73.100.20English VersionExplosion prevention and protection in underground mines -Equipment and protective systems for firedamp drainageProtection contre lexplosion dans les mines souterraines -Appareils et systme
6、s de protection destins au captagedu grisouExplosionsschutz in untertgigen Bergwerken - Gerte undSchutzsysteme zur Absaugung von GrubengasThis European Standard was approved by CEN on 13 January 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the condit
7、ions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three of
8、ficial versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria,
9、 Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE F
10、OR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2007 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14983:2007: EEN 14983:2007 (E) 2 Contents Page
11、Foreword4 Introduction .5 1 Scope 6 2 Normative references 6 3 Terms and definitions .6 4 Equipment and protective systems for firedamp drainage.8 4.1 General8 4.2 Borehole standpipes .8 4.3 Drainage pipes for seals and stoppings .12 4.4 Water separators at drainage points .12 4.5 Firedamp pipes 12
12、4.5.1 General requirements for firedamp pipes .12 4.5.2 Measuring points for measuring equipment in firedamp drainage pipes13 4.6 Pressure vessels in firedamp drainage plant .13 4.7 Exhausters13 4.7.1 Requirements for exhausters .13 4.7.2 Reserve exhausters.14 4.7.3 Location of exhausters .14 4.8 Ve
13、nting of the drained firedamp.14 4.9 Explosion prevention systems for pipelines 15 4.9.1 Explosion barriers .15 4.9.2 Non-flammable firedamp vent pipe outlets and flame arrester outlets15 4.9.3 Reserve container and operating state .16 4.10 Requirements for the design of electrical safety devices .1
14、6 4.11 Electrostatic ignition risks16 5 Instructions for installation and use17 Annex A (informative) Installation and use of firedamp drainage system 18 A.1 General18 A.2 Work on firedamp pipes18 A.3 Measures to be taken when gas levels fall below or exceed limit values during firedamp drainage 19
15、A.4 Failure or shutdown of exhausters19 Annex B (informative) Monitoring of firedamp drainage system .20 B.1 Examination and inspection by competent persons .20 B.2 Measurement of the drained firedamp mixture and pressure.20 B.2.1 Measurements taken by hand 20 B.2.2 Fixed monitoring equipment 20 B.3
16、 Documentation.21 B.4 Firedamp circuit plan 21 Annex C (informative) Requirements for location of exhausters.22 Annex D (informative) Requirements for gas removal equipment for abandoned surface outlets23 Annex E (informative) Example for calculation of t90 path27 E.1 General27 E.2 Example for calcu
17、lation of t90-path.27 Annex ZA (informative) Relationship between this European Standard and the Essential Requirements of EU Directive 94/9/EC .29 EN 14983:2007 (E) 3 Bibliography31 Figures Figure 1 Example of connection of roof borehole to collector pipe when measurement and control are accessible
18、9 Figure 2 Example of connection of roof borehole to collector pipe when measurement and control are not accessible .10 Figure 3 Example of connection of floor borehole to collector pipe when measurement and control are accessible11 Figure 4 Example of connection of floor borehole to collector pipe
19、when measurement and control are not accessible .12 Figure 5 Example of explosion prevention system for pipelines with one firedamp vent pipe 15 Figure D.1 Passive gas removal equipment (Type II).25 Figure D.2 Passive gas removal equipment (Type III)26 Figure E.1 Schematic arrangement of a t90-path
20、.28 Tables Table D.1 Requirements for gas removal equipment for abandoned surface outlets24 Table ZA.1 Correspondence between the European Standard and Directive 94/9/EC.29 EN 14983:2007 (E) 4 Foreword This document (EN 14983:2007) has been prepared by Technical Committee CEN/TC 305 “Potentially exp
21、losive atmospheres - Explosion prevention and protection”, the secretariat of which is held by DIN. This document shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 2007, and conflicting national standards shall
22、be withdrawn at the latest by September 2007. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, whic
23、h is an integral part of this document. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Gr
24、eece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 14983:2007 (E) 5 Introduction Firedamp drainage is a technical process for selected gas removal, the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN149832007ENEXPLOSIONPREVENTIONANDPROTECTIONINUNDERGROUNDMINESEQUIPMENTANDPROTECTIVESYSTEMSFORFIREDAMPDRAINAGE

链接地址:http://www.mydoc123.com/p-714645.html