EN 622-5-2009 en Fibreboards - Specifications - Part 5 Requirements for dry process boards (MDF)《纤维板 规范 第5部分 干燥处理板要求(MDF)》.pdf
《EN 622-5-2009 en Fibreboards - Specifications - Part 5 Requirements for dry process boards (MDF)《纤维板 规范 第5部分 干燥处理板要求(MDF)》.pdf》由会员分享,可在线阅读,更多相关《EN 622-5-2009 en Fibreboards - Specifications - Part 5 Requirements for dry process boards (MDF)《纤维板 规范 第5部分 干燥处理板要求(MDF)》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN 622-5:2009ICS 79.060.20NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDFibreboards SpecificationsPart 5: Requirements for dry processboards (MDF)This British Standardwas published under theauthority of the StandardsPolicy and StrategyCommittee on 31 May201
2、0. BSI 2010ISBN 978 0 580 62907 5Amendments/corrigenda issued since publicationDate CommentsBS EN 622-5:2009National forewordThis British Standard is the UK implementation of EN 622-5:2009. Itsupersedes BS EN 622-5:2006 which is withdrawn.The UK participation in its preparation was entrusted to Tech
3、nicalCommittee B/541, Wood based panels.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with a British
4、 Standard cannot confer immunityfrom legal obligations.BS EN 622-5:2009EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 622-5 November 2009 ICS 79.060.20 Supersedes EN 622-5:2006English Version Fibreboards - Specifications - Part 5: Requirements for dry process boards (MDF) Panneaux de fibres -
5、Exigences - Partie 5 : Exigences pour panneaux obtenus par procd sec (MDF) Faserplatten - Anforderungen - Teil 5: Anforderungen an Platten nach dem Trockenverfahren (MDF) This European Standard was approved by CEN on 3 October 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regul
6、ations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This
7、European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are th
8、e national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerlan
9、d and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 62
10、2-5:2009: EBS EN 622-5:2009EN 622-5:2009 (E) 2 Contents Page Foreword 3 1 Scope 4 2 Normative references 4 3 Terms and definitions .5 4 Requirements .6 4.1 General 6 4.2 Requirements for non load-bearing boards, including boards for general purpose use 7 4.2.1 Requirements for boards for use in dry
11、conditions .7 4.2.2 Requirements for boards for use in humid conditions7 4.3 Requirements for load-bearing boards .8 4.3.1 Requirements for load-bearing boards for use in dry conditions 8 4.3.2 Requirements for load-bearing boards for use in humid conditions .8 4.4 Requirements for light MDF boards
12、for non load-bearing applications, including general purpose boards 9 4.4.1 Requirements for boards for use in dry conditions .9 4.4.2 Requirements for boards for use in humid conditions. 10 4.5 Requirements for ultra-light MDF boards for non load-bearing applications, including general purpose boar
13、ds . 10 4.6 Requirements for boards for use in rigid underlays in roofing and walls 11 5 Verification of compliance . 12 5.1 General . 12 5.2 External control . 12 5.3 Factory production control 12 6 Supplementary properties . 12 7 Marking 13 7.1 Boards marketed within the European Economic Area for
14、 construction applications. 13 7.2 Other boards . 13 Annex A (normative) Boil test according to EN 1087-1 - Modified procedure . 14 Bibliography . 15 Tables Table 1 Load duration category . 5 Table 2 Examples of load-duration assignment 6 Table 3 Requirements for general purpose boards for use in dr
15、y conditions (type MDF) 7 Table 4 Requirements for general purpose boards for use in humid conditions (type MDF.H) . 7 Table 5 Requirements for load-bearing boards for use in dry conditions (type MDF.LA) 8 Table 6 Requirements for load-bearing boards for use in humid conditions (MDF.HLS) . 9 Table 7
16、 Requirements for light MDF boards for use in dry conditions (type L-MDF) 9 Table 8 Requirements for light MDF boards for use in humid conditions (type L.MDF.H) . 10 Table 9 Requirements for ultra-light MDF boards for use in dry conditions (type UL1-MDF) 10 Table 10 Requirements for ultra-light MDF
17、boards for use in dry conditions (type UL2-MDF) 11 Table 11 Requirements for use in rigid underlays in roofs and walls (type MDF.RWH) 11 Table 12 Maximum interval between test . 12 Table 13 Supplementary properties 12 BS EN 622-5:2009EN 622-5:2009 (E) 3 Foreword This document (EN 622-5:2009) has bee
18、n prepared by Technical Committee CEN/TC 112 “Wood-based panels”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2010, and conflicting national standa
19、rds shall be withdrawn at the latest by May 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 622-5:20
20、06. This standard is one of a series specifying requirements for fibreboards. The other parts of this series are listed in Clause 2 and in the bibliography. Compared to EN 622-5:2006 the following modifications have been made: a) Panel type MDF.RWH also intended for instantaneous or short-term load
21、duration as a rigid underlay in roofing and walls; b) Requirement for swelling in thickness after cyclic testing changed for panel type MDF.RWH in Table 11. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this
22、European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the Un
23、ited Kingdom. BS EN 622-5:2009EN 622-5:2009 (E) 4 1 Scope This European Standard specifies the requirements for dry process boards (MDF) as defined in EN 316. The values listed in this European Standard relate to product properties but they are not characteristic values to be used in design calculat
24、ions1). 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 310, Wood-based
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN62252009ENFIBREBOARDSSPECIFICATIONSPART5REQUIREMENTSFORDRYPROCESSBOARDSMDF 纤维板 规范 部分 干燥 处理 要求 MDFPDF

链接地址:http://www.mydoc123.com/p-712517.html