EN 54-26-2015 en Fire detection and fire alarm systems - Part 26 Carbon monoxide detectors - Point detectors《火灾探测和火灾报警系统 第26部分:一氧化碳探测器 点型探测器》.pdf
《EN 54-26-2015 en Fire detection and fire alarm systems - Part 26 Carbon monoxide detectors - Point detectors《火灾探测和火灾报警系统 第26部分:一氧化碳探测器 点型探测器》.pdf》由会员分享,可在线阅读,更多相关《EN 54-26-2015 en Fire detection and fire alarm systems - Part 26 Carbon monoxide detectors - Point detectors《火灾探测和火灾报警系统 第26部分:一氧化碳探测器 点型探测器》.pdf(84页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationBS EN 54-26:2015Fire detection and fire alarmsystemsPart 26: Carbon monoxide detectors Point detectorsBS EN 54-26:2015 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 54-26:2015.The UK participation in its preparation was entrusted to Te
2、chnicalCommittee FSH/12/2, Fire detectors.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards I
3、nstitution 2015. Published by BSI StandardsLimited 2015ISBN 978 0 580 81247 7ICS 13.220.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 April 2015.Amendments
4、issued since publicationDate Text affectedBS EN 54-26:2015EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 54-26 April 2015 ICS 13.220.20 English Version Fire detection and fire alarm systems - Part 26: Carbon monoxide detectors - Point detectors Systme de dtection et dalarme incendie - Partie 2
5、6: Dtecteurs de monoxide de carbone - Dtecteurs ponctuelsBrandmeldeanlagen - Teil 26: Kohlenmonoxidmelder - Punktfoermige Melder This European Standard was approved by CEN on 25 January 2015. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for
6、 giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three
7、 official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodi
8、es of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Sp
9、ain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CEN All rights of exploitation in any form and by any means reserved worldwi
10、de for CEN national Members. Ref. No. EN 54-26:2015 EBS EN 54-26:2015EN 54-26:2015 (E) 2 Contents Page Foreword 5 Introduction .7 1 Scope 8 2 Normative references 8 3 Terms, definitions and abbreviations 9 3.1 Terms and definitions .9 3.2 Abbreviations .9 4 Requirements .9 4.1 General 9 4.2 Nominal
11、activation conditions/sensitivity .9 4.2.1 Individual alarm indication .9 4.2.2 Rate sensitive CO response .9 4.2.3 Response to slowly developing fires.9 4.2.4 Repeatability 10 4.2.5 Directional dependence . 10 4.2.6 Reproducibility 10 4.2.7 Air movement 10 4.3 Operational reliability . 10 4.3.1 Con
12、nection of ancillary devices 10 4.3.2 Monitoring of detachable detectors 10 4.3.3 Manufacturers adjustments 10 4.3.4 On-site adjustment of behaviour . 10 4.3.5 Software controlled detectors . 11 4.3.6 Long term stability 12 4.4 Tolerance to supply voltage Variation in supply parameters 12 4.5 Perfor
13、mance parameters under fire conditions Fire sensitivity . 12 4.6 Durability of nominal activation conditions/sensitivity 12 4.6.1 Temperature resistance . 12 4.6.2 Humidity resistance 12 4.6.3 Corrosion resistance SO2corrosion (endurance) 13 4.6.4 Shock and vibration resistance . 13 4.6.5 Electrical
14、 stability EMC, immunity (operational) . 13 4.6.6 Resistance to chemical agents . 13 5 Test and assessment methods . 14 5.1 General . 14 5.1.1 Atmospheric conditions for tests . 14 5.1.2 Operating conditions for tests 14 5.1.3 Mounting arrangements . 14 5.1.4 Tolerances . 14 5.1.5 Measurement of CO
15、response value. 14 5.1.6 Provision for tests 15 5.1.7 Test schedule 15 5.2 Nominal activation conditions/sensitivity 16 5.2.1 Individual alarm indication 16 5.2.2 Rate sensitive CO response 17 5.2.3 Response to slowly developing fires 17 5.2.4 Repeatability 17 5.2.5 Directional dependence . 18 5.2.6
16、 Reproducibility 18 BS EN 54-26:2015EN 54-26:2015 (E) 3 5.2.7 Air movement . 19 5.3 Operational reliability 19 5.3.1 Connection of ancillary devices 19 5.3.2 Monitoring of detachable detectors 19 5.3.3 Manufacturers adjustments . 19 5.3.4 On-site adjustment of behaviour . 19 5.3.5 Software controlle
17、d detectors 19 5.3.6 Long term stability 19 5.4 Tolerance to supply voltage . 20 5.4.1 Variation in supply parameters 20 5.5 Performance parameters under fire conditions . 21 5.5.1 Fire sensitivity . 21 5.6 Durability of nominal activation conditions/sensitivity . 23 5.6.1 Temperature resistance 23
18、5.6.2 Humidity resistance 25 5.6.3 Corrosion resistance SO2corrosion (endurance) . 29 5.6.4 Shock and vibration resistance . 30 5.6.5 Electrical stability 34 5.6.6 Resistance to chemical agents 35 6 Assessment and verification of constancy of performance (AVCP) . 37 6.1 General . 37 6.2 Type testing
19、 . 37 6.2.1 General . 37 6.2.2 Test samples, testing and compliance criteria 38 6.2.3 Test reports 39 6.3 Factory production control (FPC) 39 6.3.1 General . 39 6.3.2 Requirements . 40 6.3.3 Product specific requirements . 42 6.3.4 Initial inspection of factory and FPC . 42 6.3.5 Continuous surveill
20、ance of FPC 43 6.3.6 Procedure for modifications. 43 6.3.7 One-off products, pre-production products, (e.g. prototypes) and products produced in very low quantities 43 7 Classification . 44 8 Marking, labelling and packaging 44 Annex A (normative) Gas test chamber for response value and cross-sensit
21、ivity . 46 A.1 General . 46 A.2 Gas test chamber specification . 46 Annex B (normative) CO and smoke measuring instruments . 48 B.1 General . 48 B.2 CO measuring instrument 48 B.3 Obscuration meter . 48 B.4 Measuring ionization chamber (MIC) . 48 Annex C (normative) Fire test room 49 C.1 General . 4
22、9 C.2 Fire test room specification 49 Annex D (informative) Establishing exposure levels of chemical agents . 52 D.1 General . 52 D.2 Establishing concentration of chemical agents for test gases 1 to 9 52 D.3 Verification of test chamber leakage . 52 D.4 Establishing concentration of ozone 52 Annex
23、E (normative) Smouldering (pyrolysis) wood fire (TF2) 54 BS EN 54-26:2015EN 54-26:2015 (E) 4 E.1 General . 54 E.2 Fuel . 54 E.3 Hotplate 54 E.4 Arrangement 54 E.5 Heating rate . 54 E.6 End of test condition 54 E.7 Test validity criteria 54 Annex F (normative) Glowing smouldering cotton fire (TF3) 59
24、 F.1 General . 59 F.2 Fuel . 59 F.3 Arrangement 59 F.4 Ignition . 60 F.5 End of test condition 60 F.6 Test validity criteria 61 Annex G (informative) Information concerning the construction of the gas test chamber 64 G.1 General . 64 G.2 Construction of the gas test chamber 64 Annex H (informative)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN54262015ENFIREDETECTIONANDFIREALARMSYSTEMSPART26CARBONMONOXIDEDETECTORSPOINTDETECTORS 火灾 探测 报警 系统 26

链接地址:http://www.mydoc123.com/p-712356.html