《EN 405-2001 en Respiratory protective devices - Valved filtering half masks to protect against gases or gases and particles - Requirements testing marking (Incorporates Amendment A.pdf》由会员分享,可在线阅读,更多相关《EN 405-2001 en Respiratory protective devices - Valved filtering half masks to protect against gases or gases and particles - Requirements testing marking (Incorporates Amendment A.pdf(48页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 405:2001 +A1:2009 Respiratory protective devices Valved filtering half masks to protect against gases or gases and particles Requirements, testing, marking ICS 13.340.30 NOCOPYINGWITHOUTBSIPERMISSIONEXCEPTASPERMITTEDBYCOPYRIGHTLAWNational foreword This British Standard is the
2、UK implementation of EN 405:2001+A1:2009. It supersedes BS EN 405:2002 which is withdrawn. The start and finish of text introduced or altered by amendment is indicated in the text by tags. Tags indicating changes to CEN text carry the number of the CEN amendment. For example, text altered by CEN ame
3、ndment A1 is indicated by !“. The UK participation in its preparation was entrusted to Technical Committee PH/4, Respiratory protection. A list of organizations represented on this subcommittee can be obtained on request to its secretary. This publication does not purport to include all the necessar
4、y provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunity from legal obligations. BS EN 405:2001+A1:2009 Amendments/corrigenda issued since publication Date Comments 31 July 2009 Implementation of CEN amendment A1:2009, a
5、nd alignment of BSI and CEN publication dates This British Standard was published under the authority of the Standards Policy and Strategy Committee on 25 February 2002 BSI 2009 ISBN 978 0 580 62118 5 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 405:2001+A1 May 2009 ICS 13.340.30 Supersedes
6、EN 405:2001 English Version Respiratory protective devices - Valved filtering half masks to protect against gases or gases and particles - Requirements, testing, marking Appareils de protection respiratoire - Demi-masques filtrants soupapes contre les gaz ou contre les gaz et les particules - Exigen
7、ces, essais, marquage Atemschutzgerte - Filtrierende Halbmasken mit Ventilen zum Schutz gegen Gase oder Gase und Partikeln - Anforderungen, Prfung, Kennzeichnung This European Standard was approved by CEN on 8 November 2001 and includes Amendment 1 approved by CEN on 26 March 2009. CEN members are b
8、ound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the
9、 CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same s
10、tatus as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Roma
11、nia, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reserved
12、worldwide for CEN national Members. Ref. No. EN 405:2001+A1:2009: E2 Contents page Foreword 4 Introduction . 5 1 Scope 6 2 Normative references 6 3 Terms and definitions . 6 4 Description . 6 5 Classification 7 5.1 General 7 5.2 Types of gas filtering half masks . 7 5.2.1 Valved gas filtering half m
13、asks 7 5.2.2 Valved multi-type gas filtering half masks 7 5.2.3 Valved combined filtering half masks . 7 5.3 Designs of combined valved filtering half masks 7 5.4 Classes of valved gas filtering half masks . 8 6 Designation 8 7 Requirements . 8 7.1 General 8 7.2 Nominal values and tolerances 8 7.3 V
14、isual inspection . 9 7.4 Packaging . 9 7.5 Practical performance . 9 7.6 Leakage . 9 7.7 Filter penetration/capacity 9 7.7.1 Particle filter penetration 9 7.7.2 Gas filtering capacity 10 7.8 Finish of parts 11 7.9 Inhalation and exhalation valves 11 7.10 Breathing resistance . 12 7.10.1 General 12 7
15、.10.2 Inhalation resistance . 12 7.10.3 Exhalation resistance 13 7.11 Clogging . 13 7.11.1 General 13 7.11.2 Devices with separable particle filters 13 7.11.3 Devices with integral or separable particle filters 13 7.11.4 Exhalation resistance 14 7.12 Compatibility with skin 14 7.13 Flammability . 14
16、 7.14 Carbon dioxide content of the inhalation air 14 7.15 Head harness . 14 7.16 Field of vision . 15 7.17 Demountable parts 15 8 Testing 15 8.1 General 15 8.2 Visual inspection . 15 8.3 Conditioning . 15 8.3.1 General 15 8.3.2 Donning and doffing 15 EN 405:2001+A1:2009 (E) BS EN 405:2001+A1:2009EN
17、 405:2001+A1:2009 (E) 3 8.3.3 Temperature . 15 8.3.4 Mechanical strength 16 8.4 Practical performance . 16 8.4.1 General 16 8.4.2 Walking test 16 8.4.3 Work simulation test . 16 8.5 Inward Leakage 17 8.5.1 General 17 8.5.2 Principle 17 8.5.3 Apparatus . 17 8.5.4 Conditioning and number of test sampl
18、es 18 8.5.5 Test subjects 18 8.5.6 Preparation of samples . 18 8.5.7 Test procedure . 19 8.5.8 Test using sulfur hexafluoride as test agent 20 8.5.9 Test using sodium chloride as test agent . 21 8.6 Gas filtering capacity 23 8.7 Flammability . 23 8.8 Carbon dioxide content of the inhalation air 23 8
19、.9 Breathing resistance . 24 8.10 Strength of attachment exhalation valve housing . 25 9 Marking . 25 9.1 Packaging . 25 9.2 Valved gas filtering half mask with separable particle filters . 25 9.2.1 Valved gas filtering half mask 25 9.2.2 Separable particle filters . 26 9.3 Valved gas filtering half
20、 masks with integral particle filters . 26 10 Information supplied by the manufacturer . 27 Annex A (informative) Marking 43 Annex ZA (informative) Clauses of this European Standard addressing essential requirements or other provisions of EU Directives 44 Bibliography 45 BS EN 405:2001+A1:2009EN 405
21、:2001+A1:2009 (E) 4 Foreword This document (EN 405:2001+A1:2009) has been prepared by Technical Committee CEN/TC 79 “Respiratory protective devices“, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identica
22、l text or by endorsement, at the latest by November 2009, and conflicting national standards shall be withdrawn at the latest by November 2009. This European Standard supersedes !EN 405:2001“. This document includes Amendment 1, approved by CEN on 2009-03-26. The start and finish of text introduced
23、or altered by amendment is indicated in the text by tags !“. This draft European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive 89/686/EEC. For relationship with EU Direct
24、ive, see informative Annex ZA, which is an integral part of this standard. The annexes A and ZA are informative. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgari
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN4052001ENRESPIRATORYPROTECTIVEDEVICESVALVEDFILTERINGHALFMASKSTOPROTECTAGAINSTGASESORGASESANDPARTICLESREQUIREMENTSTESTINGMARKINGINCORPORATESAMENDMENTAPDF

链接地址:http://www.mydoc123.com/p-711526.html