《EN 2559-1997 en Aerospace Series - Carbon Fibre Preimpregnates - Determination of the Resin and Fibre Content and the Mass of Fibre Per Unit Area《航空航天系列 碳纤维预浸带 树脂成份 纤维成份以及单位面积纤维重量测.pdf》由会员分享,可在线阅读,更多相关《EN 2559-1997 en Aerospace Series - Carbon Fibre Preimpregnates - Determination of the Resin and Fibre Content and the Mass of Fibre Per Unit Area《航空航天系列 碳纤维预浸带 树脂成份 纤维成份以及单位面积纤维重量测.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD AEROSPACE SERIES Carbon fibre preimpregnates - Determination of the resin and fibre content and the mass of fibre per unit area The European Sandard EN 2559 : 1997 has the status of a British Standard BS EN 2659 : 1997 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIG
2、HT LAW - STD-BSI BS EN 2557-ENGL 1777 = lb24bb Ob31028 Lb W BS EN 2669 : 1997 Committees responsible for this British Standard The prepamtion of this British Standard was entrusted to Technical Committee ACW64, Aerospace structural reinforced plastics, upon which the following bodies were represente
3、d: British Plastics Federation iibu.sQ of Defence Society of British Aerospace Companies This British Standard, having been prepared under the direction of the Engineering Sector Board, was published under the authority of the Standards Board and comes into effect on 15 August 1997 O BSI 1997 Amendm
4、ents issued since publication ID* ITextaffected Amd No. The following BSI references relate to the work on this standard Committee reference ACH64 Draft for comment 88/78342 DC ISBN O 680 26694 X * m * STD-BSI BS EN 2559-ENGL 1797 1624bb9 Ob31027 O22 BS EN 2669 : 1997 Contents Committees responsible
5、 pae Inside front cover National foreword ii Foreword 2 Specification 1 Scope 2 Normativereferences 3 Principle 4 Apparatusandreagents 6 Specimens 6 Procedure 7 Expressionofresults 3 3 3 4 5 8 10 8 Health and safety requirements 11 9 Designation 11 10 Testreport 12 Figures 1 2 Example of positioning
6、 of specimens on woven fibre fabrics sample across the width Example of positioning of specimens on woven carbon fibre fabric sample along an axis inclined at an angle as close as possible to the weft direction Example of positioning of specimens on carbon fibre unirectional sheet or tape sample 6 3
7、 O BSI 1997 1 STD-BSI BS EN 2559-ENGL 1997 W LbZi(bb9 Ob31030 - template of standard specimen ; - ancillary items such as a sharp knife and tweezers. 4.2 For code A method : - Erlenmeyer 250 ml double necked pear shaped flask with 50 ml dropping funnel equipped with air inlet and a water pump ; - he
8、at source with suitable temperature control ; - 400 ml beaker ; - 20 ml sintered glass crucible (n02 porosity) and suitable filtration assembly ; - desiccator containing a suitable drying agent (for example silica gel, calcium chloride or phosphorus pentoxide) ; - electric oven capable of maintainin
9、g a temperature of 120 OC with an accuracy of 5 OC ; - protective clothing and rubber gloves resistant to hydrogen peroxide and sulphuric acid solutions, safety screen for eye protection ; - concentrated sulphuric acid (specific gravity : 1,84 to 1,89) ; - hydrogen peroxide solution (concentration :
10、 300 g/l to 500 g/l) ; - acetone (propanone) ; - distilled water. * * m STD.BSI BS EN 2557-ENGL L777 Lb2Libb7 Ob3E035 32b W Page 5 EN 2559:1997 4.3 For code B method : - single thickness extraction thimble, nominal diameter 20 mm to 22 mm, nominal length 60 mm to 80 mm ; - electric oven capable of m
11、aintaining a temperature of 105 OC with an accuracy of 5 OC ; - an extraction apparatus of the Soxhlet type, comprising a condenser, siphon tube and flask and provided with an electric heating mantle ; - vacuum desiccator ; - Methyl-ethyl-ketone (MEK : butanone 2) - analytical grade - or other suita
12、ble solvent agreed between the user and manufacturer. 4.4 For code C method - container 400 ml (Erlenmeyer flask or beaker) ; - electric oven capable of maintaining a temperature of 105 OC with an accuracy of 5 OC ; - vacuum desiccator ; - a suitable solvent for extraction, as agreed between the use
13、r and manufacturer ; - acetone (propanone). 5 Specimens 5.1 Shape and dimensions The specimen shall be square and have sides of (1 O0 ? 1) mm. Other specimens may be used, subject to agreement between the user and manufacturer on condition that they have an area of 100 cm2 with a tolerance of f 2 %.
14、 5.2 Number and distribution A minimum of three specimens shall be used. They shall : - be evenly distributed across the width of the sample ; - have their centres positioned along a straight line. See figure 1 for wide woven fabrics, figure 2 for narrow woven fabrics and figure 3 for unidirectional
15、 sheet or tape. STD-BSI BS EN 2557-ENGL 1997 1b24bb7 Ob3103b 2b2 Page 6 EN 2559:1997 Dimensions in millimetres Figure 1 Example of positioning of specimens on woven carbon fibre fabrics sample across the width Dimensions in millimetres I Weft vorn I it I I Figure 2 Example of positioning of specimen
16、s on woven carbon fibre fabric sample along an axis inclined at an angle as close as possible to the weft direction - STD-BSI BS EN 2557-ENGL 1777 H 1b24bb7 Ob31037 IT7 I Width of sheet or tape Page 7 EN 2559:1997 Figure 3 Example of positioning of specimens on carbon fibre unidirectional sheet or t
17、ape sample STD-BSI BS EN 2557-ENGL 1777 = 1bZqbb7 Ob31038 035 Page 8 EN 2559:1997 6 Procedure 6.1 Conditioning 6.1.1 The amount of preimpregnate required for testing shall be sampled and then conditioned in the test atmosphere (see 6.2) for a minimum of 2 h, unless otherwise specified. Preimpregnate
18、s stored at ambient temperature 6.1.2 The preimpregnate, suitably packed in an airtight and solvent resistant bac to prevent moisture pick- up, shall be allowed to reach ambient temperature over a per d of time depending on its mass. This tuane shaii not be esc inan n. Preimpregnates stored below am
19、bient temperature. When the material has reached ambient temperature, the amount required for testing shall be sampled and then conditioned in the test atmosphere (see 6.2) for a minimum of 2 h, unless otherwise specif ied. 6.i Atmosphere for testing EN 2743. condition class B. 6.3 After conditionin
20、g, the sample shall be maintained in the test atmosphere. Unless otherwise specified, tests heil: be 23:;kd su: within 6 h. Time interval between conditioning and testing 6.4 Tests Cut the specimens 6.4.1 Code A method Use protective clothing and rubber gloves for handling hydrogen peroxide and sulp
21、huric acid solutions. The reactions shall be carried out behind the safety screen for eye protection. 6.4.1.1 Remove the protective films and weigh the specimen to the nearest milligram (m,), place it into the Erlenmeyer and carefully pour 20 ml of concentrated sulphuric acid into the flask. Fit the
22、 funnel to one neck and the water pump to the other. 6.4.1.2 Pour a suitable amount 4e.g. 20 ml of hydrogen peroxide at 500 g/l or 40 ml of hydrogen peroxide at 300 9/11 of the hydrogen peroxide solution into the dropping funnel and heat the flask gently to (160 f 10) OC until the acid starts to fum
23、e. Discontinue heating of the flask and allow the hydrogen peroxide solution to drip into the acid at the rate of about one drop every 2 s, increasing to one drop per second after 5 min. If, after all the hydrogen peroxide solution has been used, the solution is still brown, add further 5 ml portion
24、s of hydrogen peroxide solution at the latter rate and heat until the solution becomes clear. 6.4.1.3 Stop heating. When the neck of the Erlenmeyer is cool enough to handle, ensure the air inlet is open, turn the water pump off, remove the attachments from the Erlenmeyer and cool the Erlenmeyer and
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN25591997ENAEROSPACESERIESCARBONFIBREPREIMPREGNATESDETERMINATIONOFTHERESINANDFIBRECONTENTANDTHEMASSOFFIBREPERUNITAREA

链接地址:http://www.mydoc123.com/p-710077.html